Skip to main content
QUICK REVIEW

[Paper Review] Continuous Post-Market Sequential Safety Surveillance with Minimum Events to Signal

Martin Kulldorff, Ivair R. Silva|PubMed|Mar 6, 2015
Influenza Virus Research StudiesMedicine11 citations
TL;DR

This paper proposes a modified continuous sequential safety surveillance method for post-market drug and vaccine monitoring that requires a minimum number of adverse events (e.g., 3–4) before signaling, improving statistical power and reducing the expected time to signal while maintaining the nominal alpha level. The method uses exact critical values and is implemented via an open-source R package, offering practical advantages over traditional sequential methods in real-time public health surveillance systems.

ABSTRACT

The CDC Vaccine Safety Datalink project has pioneered the use of near real-time post-market vaccine safety surveillance for the rapid detection of adverse events. Doing weekly analyses, continuous sequential methods are used, allowing investigators to evaluate the data near-continuously while still maintaining the correct overall alpha level. With continuous sequential monitoring, the null hypothesis may be rejected after only one or two adverse events are observed. In this paper, we explore continuous sequential monitoring when we do not allow the null to be rejected until a minimum number of observed events have occurred. We also evaluate continuous sequential analysis with a delayed start until a certain sample size has been attained. Tables with exact critical values, statistical power and the average times to signal are provided. We show that, with the first option, it is possible to both increase the power and reduce the expected time to signal, while keeping the alpha level the same. The second option is only useful if the start of the surveillance is delayed for logistical reasons, when there is a group of data available at the first analysis, followed by continuous or near-continuous monitoring thereafter.

Motivation & Objective

  • To develop a continuous sequential surveillance method that requires a minimum number of adverse events before signaling, improving performance over standard sequential methods.
  • To maintain the correct overall alpha level while increasing statistical power and reducing the expected time to signal in post-market safety monitoring.
  • To provide exact critical values, statistical power, and average time-to-signal calculations for various scenarios, including delayed starts.
  • To support practical implementation through an open-source R package for researchers and public health agencies.
  • To optimize near real-time safety surveillance systems by balancing type I error, power, and time to detection.

Proposed method

  • Uses the maximized sequential probability ratio test (MaxSPRT) for Poisson-distributed adverse events in continuous sequential monitoring.
  • Introduces a minimum event threshold (M ≥ 3) before rejecting the null hypothesis, even if the sequential test statistic crosses the boundary earlier.
  • Calculates exact critical values using numerical methods, avoiding simulations or asymptotic approximations.
  • Incorporates delayed start scenarios (D > 0) by adjusting critical values to maintain the correct alpha level when surveillance begins after initial exposure.
  • Employs exact power and expected time-to-signal calculations under various relative risk assumptions.
  • Provides an open-source R package 'Sequential' for users to compute critical values, power, and time-to-signal for custom parameter settings.

Experimental results

Research questions

  • RQ1Can requiring a minimum number of adverse events before signaling improve statistical power and reduce the expected time to signal in continuous sequential post-market surveillance?
  • RQ2How do delayed starts affect the performance of continuous sequential surveillance, and how can critical values be adjusted to maintain the correct alpha level?
  • RQ3What is the optimal minimum event threshold (M) that balances type I error, power, and time to signal across different relative risk scenarios?
  • RQ4How does the proposed method compare to standard MaxSPRT in terms of performance metrics when applied to real-world safety surveillance data?
  • RQ5Can exact critical values be computed efficiently and made publicly available to support widespread adoption in public health monitoring systems?

Key findings

  • Requiring a minimum of 3–4 adverse events before signaling increases statistical power and reduces the expected time to signal while maintaining the nominal alpha level.
  • For M = 4, the critical values and performance metrics are identical to those of M = 1 when the delayed start D ≥ 1, due to inherent constraints in early signaling.
  • The method allows for a significant improvement in early detection capability without inflating the type I error rate, even when the true relative risk is moderate.
  • The average time to signal is reduced by several weeks in high-risk scenarios (e.g., relative risk > 2), particularly when M = 4 is used.
  • The open-source R package 'Sequential' enables users to compute exact critical values, power, and expected time-to-signal for any combination of parameters, including delayed starts and minimum event thresholds.
  • The proposed method has already been adopted by the CDC Vaccine Safety Datalink project, demonstrating real-world applicability and performance gains.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.