[Paper Review] Controlling the error mechanism in a tunable-barrier non-adiabatic charge pump by dynamic gate compensation
This paper demonstrates dynamic gate compensation in a GaAs-based tunable-barrier non-adiabatic single-electron pump to suppress backtunneling errors by controlling the plunger-to-barrier ratio ∆ptb. By modulating a second gate to slow the effective energy level shift, the authors achieve several orders of magnitude error suppression at zero magnetic field, verified experimentally with sub-ppm precision, confirming the decay cascade model and enabling a controlled transition to thermal error dominance.
Single-electron pumps based on tunable-barrier quantum dots are the most promising candidates for a direct realization of the unit ampere in the recently revised SI: they are simple to operate and show high precision at high operation frequencies. The current understanding of the residual transfer errors at low temperature is based on the evaluation of backtunneling effects in the decay cascade model. This model predicts a strong dependence on the ratio of the time dependent changes in the quantum dot energy and the tunneling barrier transparency. Here we employ a two-gate operation scheme to verify this prediction and to demonstrate control of the backtunneling error. We derive and experimentally verify a quantitative prediction for the error suppression, thereby confirming the basic assumptions of the backtunneling (decay cascade) model. Furthermore, we demonstrate a controlled transition from the backtunneling dominated regime into the thermal (sudden decoupling) error regime. The suppression of transfer errors by several orders of magnitude at zero magnetic field was additionally verified by a sub-ppm precision measurement.
Motivation & Objective
- To control and suppress backtunneling errors in non-adiabatic single-electron pumps using dynamic gate compensation.
- To experimentally verify the quantitative predictions of the decay cascade model for error suppression.
- To demonstrate a controlled transition from backtunneling-dominated to thermal error-dominated regimes.
- To achieve sub-ppm uncertainty in current measurement, validating the pump's precision for SI ampere realization.
Proposed method
- Employed a two-gate operation scheme with a dynamically modulated second gate to slow the effective energy level shift in the quantum dot.
- Used geometric arguments to derive a quantitative prediction for error suppression based on the ratio of gate voltage changes.
- Applied custom waveforms via an arbitrary waveform generator (12 GS/s) with low-pass filtering to minimize high-frequency noise.
- Conducted measurements at 100 mK in a dilution refrigerator with ultrastable low-noise current amplifiers (ULCA) for sub-ppm current noise floor.
- Acquired two-dimensional pumping maps in the V_DC1–V_DC2 plane to identify optimal working points.
- Performed precision current measurements with uncertainty below 0.2 ppm to verify error suppression.
Experimental results
Research questions
- RQ1Can dynamic gate compensation suppress backtunneling errors in a non-adiabatic single-electron pump?
- RQ2Does the observed error suppression match the quantitative prediction from the decay cascade model?
- RQ3Can the system be tuned from backtunneling-dominated to thermally dominated error regimes?
- RQ4What is the achievable accuracy of the pump when backtunneling errors are suppressed by several orders of magnitude?
Key findings
- Backtunneling errors were suppressed by several orders of magnitude through dynamic gate compensation, achieving sub-ppm uncertainty in current measurement.
- The experimental results confirmed the quantitative prediction of the decay cascade model for error suppression based on the plunger-to-barrier ratio ∆ptb.
- A controlled transition from backtunneling-dominated to thermal error-dominated regimes was demonstrated by adjusting the gate modulation.
- The pump achieved a current of approximately 13.5 pA (at 85.4 MHz) with a measured uncertainty of 0.2 ppm, validating its suitability for SI ampere realization.
- The suppression of errors was achieved without applying an external magnetic field, highlighting the method's robustness.
- The study confirmed that the dominant error mechanism can be actively controlled via gate engineering, enabling high-precision operation.