Skip to main content
QUICK REVIEW

[Paper Review] Deep learning based CT-to-CBCT deformable image registration for autosegmentation in head and neck adaptive radiation therapy

Xiao Liang, Howard E. Morgan|arXiv (Cornell University)|Feb 1, 2021
Advanced Radiotherapy TechniquesPhysics and Astronomy14 references7 citations
TL;DR

This study proposes a deep learning framework that jointly generates synthetic CT (sCT) and performs deformable image registration from CBCT to pCT for automatic segmentation in head and neck adaptive radiation therapy. By combining a CycleGAN and a 5-cascaded Voxelmorph network, the method achieves high-accuracy contour propagation with a mean Dice score of 0.83 and 95% Hausdorff distance of 2.01 mm, outperforming standard methods in accuracy and efficiency.

ABSTRACT

The purpose of this study is to develop a deep learning based method that can automatically generate segmentations on cone-beam CT (CBCT) for head and neck online adaptive radiation therapy (ART), where expert-drawn contours in planning CT (pCT) can serve as prior knowledge. Due to lots of artifacts and truncations on CBCT, we propose to utilize a learning based deformable image registration method and contour propagation to get updated contours on CBCT. Our method takes CBCT and pCT as inputs, and output deformation vector field and synthetic CT (sCT) at the same time by jointly training a CycleGAN model and 5-cascaded Voxelmorph model together.The CycleGAN serves to generate sCT from CBCT, while the 5-cascaded Voxelmorph serves to warp pCT to sCT's anatommy. The segmentation results were compared to Elastix, Voxelmorph and 5-cascaded Voxelmorph on 18 structures including left brachial plexus, right brachial plexus, brainstem, oral cavity, middle pharyngeal constrictor, superior pharyngeal constrictor, inferior pharyngeal constrictor, esophagus, nodal gross tumor volume, larynx, mandible, left masseter, right masseter, left parotid gland, right parotid gland, left submandibular gland, right submandibular gland, and spinal cord. Results show that our proposed method can achieve average Dice similarity coefficients and 95% Hausdorff distance of 0.83 and 2.01mm. As compared to other methods, our method has shown better accuracy to Voxelmorph and 5-cascaded Voxelmorph, and comparable accuracy to Elastix but much higher efficiency. The proposed method can rapidly and simultaneously generate sCT with correct CT numbers and propagate contours from pCT to CBCT for online ART re-planning.

Motivation & Objective

  • To address the challenge of inaccurate and time-consuming manual contouring on CBCT images in online adaptive radiation therapy (ART).
  • To develop a fast and accurate method for propagating expert-drawn contours from planning CT (pCT) to cone-beam CT (CBCT) despite artifacts and truncations.
  • To generate synthetic CT (sCT) with accurate Hounsfield units from CBCT using deep learning.
  • To enable real-time, automated contouring for online replanning in head and neck cancer radiotherapy.

Proposed method

  • A CycleGAN is trained to translate CBCT images into synthetic CT (sCT) with accurate Hounsfield unit values.
  • A 5-cascaded Voxelmorph network performs deformable image registration from pCT to the generated sCT.
  • The CycleGAN and Voxelmorph networks are jointly trained to ensure consistency between sCT generation and anatomical warping.
  • Contour propagation is performed by applying the deformation field from Voxelmorph to the original pCT contours.
  • The framework leverages end-to-end learning to improve registration accuracy and sCT quality simultaneously.
  • The method is evaluated on 18 head and neck structures using Dice and 95% Hausdorff distance metrics.

Experimental results

Research questions

  • RQ1Can a deep learning-based method jointly generate accurate synthetic CT and perform reliable deformable registration from CBCT to pCT?
  • RQ2How does the proposed method compare to conventional methods like Elastix and standard Voxelmorph in segmentation accuracy and computational efficiency?
  • RQ3Can the joint training of CycleGAN and cascaded Voxelmorph improve contour propagation performance on CBCT with artifacts and truncations?
  • RQ4Does the method maintain accurate Hounsfield unit values in the generated sCT for clinical use?
  • RQ5Can the framework enable rapid, automated contouring for online adaptive replanning in head and neck radiotherapy?

Key findings

  • The proposed method achieved a mean Dice similarity coefficient of 0.83 across 18 head and neck structures, indicating high segmentation accuracy.
  • The 95% Hausdorff distance was 2.01 mm, reflecting precise boundary alignment despite image artifacts.
  • The method outperformed standard Voxelmorph and 5-cascaded Voxelmorph in both Dice and Hausdorff distance metrics.
  • It achieved comparable accuracy to Elastix but with significantly higher computational efficiency.
  • The joint training of CycleGAN and cascaded Voxelmorph improved the consistency and quality of both sCT generation and contour propagation.
  • The method enables rapid, automated, and clinically feasible contour propagation for online adaptive radiotherapy.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.