[Paper Review] Deep searches for X-ray pulsations from Scorpius X-1 and Cygnus X-2 in support of continuous gravitational wave searches
This study performs deep semi-coherent X-ray searches for pulsations in Sco X-1 and Cygnus X-2 using RXTE/PCA data to constrain neutron star spin frequencies, enabling more sensitive continuous gravitational wave (GW) searches. Despite analyzing ~104 hr (Sco X-1) and ~48 hr (Cygnus X-2) of data, no pulsations were detected, yielding the most stringent 90% confidence upper limits on fractional pulse amplitude: 0.034% for Sco X-1 and 0.23% for Cygnus X-2—improving on prior limits by factors of ~8.2 and ~1.6, respectively.
Neutron stars in low mass X-ray binaries are hypothesised to emit continuous gravitational waves that may be detectable by ground-based observatories. The torque balance model predicts that a higher accretion rate produces larger-amplitude gravitational waves, hence low mass X-ray binaries with high X-ray flux are promising targets for gravitational wave searches. The detection of X-ray pulsations would identify the spin frequency of these neutron stars, and thereby improve the sensitivity of continuous gravitational-wave searches by reducing the volume of the search parameter space. We perform a semi-coherent search for pulsations in the two low mass X-ray binaries Scorpius X-1 and Cygnus X-2 using X-ray data from the extit{ Rossi X-ray Timing Explorer} Proportional Counter Array. We find no clear evidence for pulsations, and obtain upper limits (at $90\%$ confidence) on the fractional pulse amplitude, with the most stringent being $0.034\%$ for Scorpius X-1 and $0.23\%$ for Cygnus X-2. These upper limits improve upon those of Vaughan et al. (1994) by factors of $\sim 8.2$ and $\sim 1.6$ respectively.
Motivation & Objective
- To improve the sensitivity of continuous gravitational wave (GW) searches by constraining neutron star spin frequencies in low-mass X-ray binaries (LMXBs).
- To reduce the parameter space volume in GW searches by identifying spin frequencies via X-ray pulsation detection.
- To perform deep, semi-coherent searches for persistent X-ray pulsations in Sco X-1 and Cygnus X-2 using archival RXTE/PCA data.
- To set improved upper limits on fractional pulse amplitudes, surpassing previous results from Vaughan et al. (1994).
Proposed method
- Utilized semi-coherent search techniques developed by Messenger (2011), adapted for X-ray pulsation detection in LMXBs.
- Processed ~143 hours of RXTE/PCA data in 'EVENT', 'BINNED', and 'SINGLE BIT' modes with high time resolution (<1 ms) for light curve analysis.
- Applied Doppler phase correction for binary orbital motion and accounted for potential spin wandering by segmenting data into coherent intervals.
- Used a detection statistic Σ to identify candidate signals, with false alarm thresholds set at 1% and 10% to assess significance.
- Validated the method’s sensitivity using simulated signals with known amplitudes (e.g., 0.034% for Sco X-1), confirming recovery at the 90% confidence level.
- Performed searches under two assumptions: with and without spin wandering constraints, to test robustness of results.
Experimental results
Research questions
- RQ1Can persistent X-ray pulsations be detected in Sco X-1 and Cygnus X-2 using deep, semi-coherent analysis of RXTE/PCA data?
- RQ2What are the most stringent upper limits on fractional pulse amplitudes for Sco X-1 and Cygnus X-2 based on this analysis?
- RQ3How do these upper limits compare to previous results, particularly those from Vaughan et al. (1994)?
- RQ4To what extent does the presence of spin wandering affect the sensitivity and reliability of X-ray pulsation searches?
- RQ5Can the method detect weak, persistent pulsations with fractional amplitudes as low as 0.034% at 90% confidence?
Key findings
- No significant evidence for persistent X-ray pulsations was found in either Sco X-1 or Cygnus X-2 across ~104.4 hr and ~48.5 hr of on-source observation time, respectively.
- The most stringent 90% confidence upper limit on the fractional pulse amplitude is 0.034% for Sco X-1, representing an improvement by a factor of ~8.2 over the prior limit from Vaughan et al. (1994).
- For Cygnus X-2, the 90% confidence upper limit is 0.23%, improving on the prior limit by a factor of ~1.6.
- The semi-coherent search method successfully recovered a simulated signal with a 0.034% fractional amplitude at the 1% false alarm threshold, confirming its sensitivity to such weak signals.
- The method’s performance is robust to uncertainties in orbital parameters and spin wandering, as demonstrated by consistent parameter estimation in simulated data.
- The results are consistent with other null detections in LMXBs and suggest pulsations may be weak, intermittent, or suppressed by scattering in optically thick environments.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.