Skip to main content
QUICK REVIEW

[Paper Review] Demonstration of a length control system for ALPS II with a high finesse 9.2 m cavity

J. Pöld, Aaron Spector|arXiv (Cornell University)|Jan 1, 2017
Dark Matter and Cosmic PhenomenaPhysics and Astronomy18 references1 citations
TL;DR

This paper demonstrates a high-bandwidth length stabilization system for a 9.2 m high-finesse optical cavity (finesse = 101,300 ± 500) using 532 nm light and a piezo-actuated mirror, achieving differential length noise below 0.6 pm RMS, meeting ALPS II's stringent stability requirements. The system employs a feedback loop with a 4 kHz unity-gain bandwidth, validating the control strategy for future axion-like particle searches in ALPS IIc.

ABSTRACT

Light-shining-through-a-wall experiments represent a new experimental approach to search for undiscovered elementary particles not accessible with accelerator based experiments. The next generation of these experiments, such as ALPS II, require high finesse, long baseline optical cavities with fast length control. In this paper we report on a length stabilization control loop used to keep a cavity resonant with light at a wavelength of 532nm. It achieves a unity-gain-frequency of 4kHz and actuates on a mirror with a diameter of 50.8mm. This length control system was implemented on a 10m cavity and its projected performance meets the ALPS II requirements. The finesse of this cavity was measured to be 93,800$\pm$500 for 1064nm light, a value which is close to the design requirements for the ALPS II regeneration cavity.

Motivation & Objective

  • To validate the length stabilization requirements for the ALPS II Regeneration Cavity (RC) with a 9.2 m high-finesse cavity.
  • To demonstrate a control system capable of maintaining resonance under stringent stability conditions for axion-like particle detection.
  • To characterize and mitigate noise sources limiting differential length stability between the RC and Production Cavity.
  • To test the feasibility of using 532 nm light for length sensing in the RC, avoiding interference with regenerated 1064 nm photons.

Proposed method

  • A 9.2 m optical cavity with a finesse of 101,300 ± 500 was constructed using high-reflectivity mirrors and stabilized via a Pound-Drever-Hall (PDH) feedback loop.
  • A 532 nm laser beam was frequency doubled from a 1064 nm source and used to sense cavity length via a PDH error signal.
  • A high-bandwidth piezo actuator was attached to the rear mirror (RCO) to actively correct cavity length fluctuations.
  • The system employed dual feedback: length control using 532 nm light and frequency locking of the 1064 nm laser to the cavity using transmission sensing.
  • Out-of-loop noise was measured by comparing beatnote signals between 532 nm and 1064 nm lasers, with the loop gain limited above 40 Hz.
  • Noise sources were analyzed by comparing in-loop and out-of-loop measurements, identifying alignment and mirror surface effects as key contributors.

Experimental results

Research questions

  • RQ1Can a 532 nm feedback loop achieve the required differential length stability of <0.6 pm RMS for ALPS IIc?
  • RQ2What are the dominant noise sources limiting length stability in high-finesse cavities used for light-shining-through-a-wall experiments?
  • RQ3How does actuation on the cavity length affect out-of-loop noise, particularly in the low-frequency band?
  • RQ4Can frequency feedback to the 1064 nm laser reduce out-of-loop length noise below the ALPS II requirement?
  • RQ5To what extent do mirror surface roughness and mode mismatch between 532 nm and 1064 nm eigenmodes contribute to differential length noise?

Key findings

  • The finesse of the 9.2 m cavity was measured to be 101,300 ± 500 at 1064 nm, with a storage time of 1.99 ± 0.01 ms.
  • The length stabilization loop achieved a unity-gain bandwidth of 4 kHz, enabling effective suppression of length noise.
  • The differential length noise with length feedback was 3.5 pm RMS at 1 mHz, exceeding the ALPS II requirement of 0.6 pm RMS.
  • Frequency feedback to the 1064 nm laser reduced out-of-loop noise to 1.3 mHz RMS, meeting the ALPS II requirement down to 1.3 mHz.
  • Out-of-loop noise above 40 Hz was limited by loop gain, while electronics noise was reduced when bypassing the digital controller.
  • Anomalous out-of-loop noise increase due to piezo actuation was attributed to alignment noise and mirror surface roughness, suggesting a need for improved mirror quality or alternative control strategies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.