Skip to main content
QUICK REVIEW

[Paper Review] Design and Control of a Highly Redundant Rigid-Flexible Coupling Robot to Assist the COVID-19 Oropharyngeal-Swab Sampling

Yingbai Hu, Jian Li|arXiv (Cornell University)|Feb 25, 2021
COVID-19 diagnosis using AIMedicine5 citations
TL;DR

This paper presents a 9-degree-of-freedom rigid-flexible coupling (RFC) robot for safe, automated oropharyngeal swab sampling during the COVID-19 pandemic. Equipped with a micro-pneumatic actuator, force sensing, and a vision system, the robot uses a varying-parameter zeroing neural network (VP-ZNN) for real-time motion planning under physical and occlusion constraints, achieving 93% recognition accuracy and sub-0.2 mm control precision in human volunteer trials with sampling times under 20 seconds.

ABSTRACT

The outbreak of novel coronavirus pneumonia (COVID-19) has caused mortality and morbidity worldwide. Oropharyngeal-swab (OP-swab) sampling is widely used for the diagnosis of COVID-19 in the world. To avoid the clinical staff from being affected by the virus, we developed a 9-degree-of-freedom (DOF) rigid-flexible coupling (RFC) robot to assist the COVID-19 OP-swab sampling. This robot is composed of a visual system, UR5 robot arm, micro-pneumatic actuator and force-sensing system. The robot is expected to reduce risk and free up the clinical staff from the long-term repetitive sampling work. Compared with a rigid sampling robot, the developed force-sensing RFC robot can facilitate OP-swab sampling procedures in a safer and softer way. In addition, a varying-parameter zeroing neural network-based optimization method is also proposed for motion planning of the 9-DOF redundant manipulator. The developed robot system is validated by OP-swab sampling on both oral cavity phantoms and volunteers.

Motivation & Objective

  • To reduce infection risk for healthcare workers during oropharyngeal swab sampling by automating the procedure.
  • To address the fragility of the human oropharyngeal cavity by enabling soft, compliant, and safe sampling using a flexible actuator.
  • To develop a motion planning method that satisfies multiple constraints—physical limits, remote center of motion (OCC), and task requirements—on a redundant 9-DOF manipulator.
  • To validate the system’s safety, accuracy, and clinical feasibility through phantom and human volunteer experiments.

Proposed method

  • A 9-DOF rigid-flexible coupling robot integrates a UR5 arm, micro-pneumatic actuator (MPA), force-sensing system, and RealSense D435i for visual perception.
  • The MPA is a soft, 7.5 mm diameter, disposable actuator that enables compliant, low-force interaction with the oral cavity.
  • A vision system using Mask R-CNN with Inception v4 backbone detects oral anatomy (e.g., tonsils) from depth images with 95% recognition rate on phantoms.
  • A varying-parameter zeroing neural network (VP-ZNN) is proposed to solve a multi-constrained optimization problem online, incorporating joint limits, task space trajectories, and OCC constraints.
  • The robot plans piecewise straight-line trajectories in Cartesian space using minimum-jerk curves, with joint motion constrained within physical and velocity limits.
  • The system uses a quick-connect disposable MPA with protective film to maintain sterility between patients.

Experimental results

Research questions

  • RQ1Can a redundant, rigid-flexible coupling robot safely and accurately perform oropharyngeal swab sampling while minimizing risk to clinical staff?
  • RQ2How can a soft, compliant actuator improve safety and reduce injury risk during oropharyngeal sampling compared to rigid end-effectors?
  • RQ3Can a real-time optimization method like VP-ZNN effectively handle multiple constraints (physical limits, OCC, task trajectory) in a 9-DOF redundant manipulator?
  • RQ4What is the performance of the robot in terms of recognition accuracy, control precision, and sampling time on human volunteers?

Key findings

  • The robot achieved 93% recognition accuracy in detecting target sampling sites on human volunteers using Mask R-CNN-based visual detection.
  • Control precision was maintained within ≤0.2 mm in both phantom and volunteer experiments, with tracking errors converging to ≤0.02 mm.
  • Average sampling time was 18 ± 2 seconds on phantoms and 20 ± 4 seconds on volunteers, meeting the goal of rapid, standardized sampling.
  • The average sampling contact force was approximately 150 mN, indicating safe, compliant interaction with the oral cavity.
  • RT-PCR testing confirmed that robotic swabs were of high quality, with 96.67% of samples having Ct values ≤37 (qualified), comparable to manual sampling (100% qualified).
  • The VP-ZNN method demonstrated faster convergence and smaller errors than prior methods, validating its effectiveness in real-time constrained optimization.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.