TL;DR

This paper presents the design, fabrication, and validation of high-voltage electrode grids—specifically the cathode, gate, anode, and bottom grids—for the LZ dual-phase xenon time projection chamber. Engineered for uniform electric fields and minimal background, the grids enable efficient electron drift and electroluminescence S2 signal production, with sub-millimeter alignment accuracy achieved through rigorous testing, ensuring high sensitivity for WIMP dark matter detection at 1.5×10⁻⁴⁸ cm² (90% C.L.).

ABSTRACT

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. We follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

Motivation & Objective

  • To design and produce high-voltage electrode grids for the LZ dual-phase xenon TPC that maintain strong, uniform electric fields across liquid and gas phases.
  • To minimize radiogenic and field-induced backgrounds from the grids to preserve WIMP detection sensitivity.
  • To ensure mechanical stability and precise alignment of the gate and anode grids to maintain S2 signal resolution.
  • To validate grid performance through environmental testing, deflection measurements, and radon exposure modeling.
  • To support the LZ experiment’s goal of achieving a WIMP spin-independent cross-section sensitivity of 1.5×10⁻⁴⁸ cm² (90% C.L.)

Proposed method

  • Employed four woven mesh wire grids (cathode, gate, anode, bottom) spanning 1.456 m diameter to establish uniform electric fields in liquid and gas xenon.
  • Designed the electron extraction region with a 5 kV/cm extraction field and 10 kV/cm electroluminescence field to maximize S2 signal yield.
  • Used finite element modeling and mechanical testing to predict and validate grid deflections under high voltage, achieving <1.8 mm total deflection.
  • Conducted cleanroom exposure time tracking and radon daughter plate-out modeling to estimate ²¹⁰Pb background from air exposure during production.
  • Performed electropolishing and passivation treatments to reduce intrinsic radioactive contamination from wire materials.
  • Conducted in-situ deflection measurements in air under varying voltage differentials to validate mechanical stability and model accuracy.

Experimental results

Research questions

  • RQ1How can high-voltage electrode grids be designed to maintain strong, uniform electric fields in dual-phase xenon while minimizing radiogenic and field-induced backgrounds?
  • RQ2What mechanical tolerances are required to preserve S2 signal resolution, and how can grid alignment be validated to meet these constraints?
  • RQ3What is the contribution of radon daughter plate-out on wire surfaces during production and testing, and how can it be estimated and mitigated?
  • RQ4How do intrinsic radioactive contaminants in the wire material contribute to background, and what are their upper limits?
  • RQ5To what extent does grid geometry and fabrication process affect electron drift uniformity and S2 pulse shape in the TPC?

Key findings

  • The gate and anode grids exhibited a combined deflection of 1.8 mm under high voltage, confirming mechanical stability and meeting the <2 mm requirement for S2 resolution.
  • The contribution of grid misalignment to S2 resolution was estimated to be at the 0.1% level or better, ensuring high position resolution.
  • Radon exposure modeling estimated ²¹⁰Pb activity on wires between 0.3 mBq (bottom grid) and 88.0 mBq (anode grid), with pessimistic estimates driven by uncertain HEPA flow effects.
  • Intrinsic radioactive contamination from wire batches was constrained by assay, with upper limits on ²³⁸Ue, ²³⁸Ul, ²³²Th, ²³²Thl, and ⁴⁰K consistent with optimistic radon plate-out estimates.
  • The validation campaign successfully informed design modifications to reduce breakdown and electron emission risks in the extraction region.
  • The grids were successfully integrated into the LZ TPC in spring 2019, supporting the experiment’s target sensitivity of 1.5×10⁻⁴⁸ cm² (90% C.L.) for WIMP detection.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint