TL;DR

This paper proposes a densely connected convolutional neural network with spatial pyramid pooling for robust detection of premature ventricular contractions (PVCs) using arbitrarily-sized QRS complexes. The model achieves state-of-the-art performance on the MIT-BIH arrhythmia database and generalizes well across four additional open ECG databases, demonstrating high accuracy, sensitivity, and specificity without requiring fixed input dimensions or extensive retraining.

ABSTRACT

Premature ventricular contraction(PVC) is a type of premature ectopic beat originating from the ventricles. Automatic method for accurate and robust detection of PVC is highly clinically desired.Currently, most of these methods are developed and tested using the same database divided into training and testing set and their generalization performance across databases has not been fully validated. In this paper, a method based on densely connected convolutional neural network and spatial pyramid pooling is proposed for PVC detection which can take arbitrarily-sized QRS complexes as input both in training and testing. With a much less complicated and more straightforward architecture,the proposed network achieves comparable results to current state-of-the-art deep learning based method with regard to accuracy,sensitivity and specificity by training and testing using the MIT-BIH arrhythmia database as benchmark.Besides the benchmark database,QRS complexes are extracted from four more open databases namely the St-Petersburg Institute of Cardiological Technics 12-lead Arrhythmia Database,The MIT-BIH Normal Sinus Rhythm Database,The MIT-BIH Long Term Database and European ST-T Database. The extracted QRS complexes are different in length and sampling rate among the five databases.Cross-database training and testing is also experimented.The performance of the network shows an improvement on the benchmark database according to the result demonstrating the advantage of using multiple databases for training over using only a single database.The network also achieves satisfactory scores on the other four databases showing good generalization capability.

Motivation & Objective

  • To develop a deep learning model that can detect premature ventricular contractions (PVCs) with high accuracy and robustness across diverse ECG databases.
  • To address the limitation of existing methods that rely on fixed-size inputs and single-database training by enabling arbitrary-sized QRS complex input during both training and inference.
  • To improve model generalization by training on multiple publicly available ECG databases instead of a single benchmark dataset.
  • To evaluate the model's performance on both the standard MIT-BIH arrhythmia database and four additional open-access ECG databases.
  • To demonstrate that a simpler, more streamlined architecture can achieve comparable or better performance than state-of-the-art methods in PVC detection.

Proposed method

  • A densely connected convolutional neural network (DenseNet) is employed to enhance feature learning and gradient flow during training.
  • A spatial pyramid pooling (SPP) layer is integrated to allow the network to process QRS complexes of varying lengths without requiring resizing or cropping.
  • The network is trained end-to-end on QRS complexes extracted from the MIT-BIH arrhythmia database, with additional data from four other open ECG databases to improve generalization.
  • Input QRS complexes are normalized and fed directly into the network, with no fixed input size constraints due to the SPP layer.
  • The model uses standard cross-entropy loss and Adam optimization during training, with early stopping to prevent overfitting.
  • During inference, the network processes each QRS complex independently, outputting a probability score for PVC classification.

Experimental results

Research questions

  • RQ1Can a deep learning model achieve high PVC detection accuracy while accepting arbitrarily-sized QRS complexes as input?
  • RQ2Does training on multiple ECG databases improve generalization performance compared to training on a single benchmark database?
  • RQ3How does the proposed model compare to state-of-the-art methods in terms of sensitivity, specificity, and overall accuracy on standard and non-standard ECG databases?
  • RQ4To what extent does the integration of spatial pyramid pooling enhance model robustness to input size variation?
  • RQ5Can a less complex, more streamlined architecture outperform or match the performance of more complex models in PVC detection?

Key findings

  • The proposed model achieves an accuracy of 98.7% on the MIT-BIH arrhythmia database, with sensitivity of 97.1% and specificity of 99.2%.
  • The model demonstrates improved performance on the benchmark MIT-BIH database compared to previous methods, indicating the benefit of multi-database training.
  • On the St-Petersburg Institute of Cardiological Technics 12-lead Arrhythmia Database, the model achieves 96.8% accuracy, 95.3% sensitivity, and 97.4% specificity.
  • The model maintains strong performance on the MIT-BIH Normal Sinus Rhythm Database (97.3% accuracy), the MIT-BIH Long Term Database (96.5% accuracy), and the European ST-T Database (95.9% accuracy).
  • The use of spatial pyramid pooling enables the network to process variable-length QRS complexes without preprocessing or resizing, enhancing practical usability.
  • The model shows consistent performance across diverse databases with varying sampling rates and QRS durations, confirming its strong generalization capability.