[Paper Review] Determination of carbohydrates in infant milk powders by ultra-performance liquid chromatography with evaporative light scattering detector and BEH HILIC column

Hyon-Hui Ri, Yong-A Choe|arXiv (Cornell University)|Nov 20, 2017
Diet, Metabolism, and DiseaseMedicine3 citations
TL;DR

This study develops and validates an ultra-performance liquid chromatography (UPLC) method with an evaporative light scattering detector (ELSD) and BEH HILIC column for the simultaneous quantification of five key carbohydrates—fructose, glucose, sucrose, lactose, and fructo-oligosaccharide—in infant milk powders. The method achieves baseline separation, low limits of detection (down to 16.4 mg/L), and excellent precision and recovery (95.0–105.4%), demonstrating high accuracy and robustness for routine quality control in infant formula analysis.

ABSTRACT

The possibility of carbohydrate separation in BEH HILIC (Ethylene Bridged Hybride, Hydrophilic Interaction Liquid Chromatography) column was studied by ultra-performance liquid chromatography (UPLC) with evaporative light scattering detector (ELSD) and mobile phase containing amine compounds as modifiers. The chromatography conditions and ELSD parameters were optimized to separate five typical carbohydrates and applied to analysis of four infant milk powders. The linear ranges of carbohydrate determination were 20-300mg/L for fructose and glucose, 20-250mg/L for sucrose and lactose, and 35-180mg/L for fructo-oligosaccharide. The LODs were 16.4mg/L for fructose and glucose, 17.3mg/L for sucrose, 20.0mg/L for lactose, and 46.7mg/L for fructo-oligosaccharide. Relative standard deviations (RSDs) ranged between 3.45-4.23%, 1.46-4.17%, 4.14-5.60%, 1.39-4.09%, and 2.49-3.61% for fructose, glucose, sucrose, lactose, and fructo-oilgosaccharide, respectively and recoveries ranged between 95.0 and 105.4%

Motivation & Objective

  • To develop a reliable analytical method for the simultaneous determination of multiple carbohydrates in infant milk powders.
  • To address the challenge of separating polar carbohydrates with high retention and sensitivity using UPLC-ELSD.
  • To optimize chromatographic conditions and ELSD parameters for improved resolution and detection limits.
  • To validate the method for accuracy, precision, and linearity across a range of carbohydrate concentrations.

Proposed method

  • Employed ultra-performance liquid chromatography (UPLC) with a BEH HILIC column for enhanced separation of polar carbohydrates.
  • Used a mobile phase containing amine compounds as modifiers to improve peak shape and retention of hydrophilic analytes.
  • Applied an evaporative light scattering detector (ELSD) for sensitive, non-destructive detection of carbohydrates without chromophores.
  • Optimized UPLC parameters including flow rate, temperature, and gradient elution to achieve baseline separation of fructose, glucose, sucrose, lactose, and fructo-oligosaccharide.
  • Conducted system suitability and method validation tests including linearity, limits of detection (LOD), limits of quantification (LOQ), precision, and recovery.

Experimental results

Research questions

  • RQ1Can BEH HILIC-UPLC-ELSD provide baseline separation of five major carbohydrates in infant milk powders?
  • RQ2What are the optimal UPLC and ELSD parameters for achieving high sensitivity and precision in carbohydrate quantification?
  • RQ3What are the limits of detection and quantification for each carbohydrate under the developed method?
  • RQ4How accurate and reproducible is the method across different concentration levels and real infant milk powder samples?

Key findings

  • The method achieved linear ranges of 20–300 mg/L for fructose and glucose, 20–250 mg/L for sucrose and lactose, and 35–180 mg/L for fructo-oligosaccharide.
  • Limits of detection were 16.4 mg/L for fructose and glucose, 17.3 mg/L for sucrose, 20.0 mg/L for lactose, and 46.7 mg/L for fructo-oligosaccharide.
  • Relative standard deviations (RSDs) ranged from 1.39% to 5.60%, indicating high precision across all analytes.
  • Recoveries for all carbohydrates were between 95.0% and 105.4%, confirming high accuracy and reliability.
  • The method successfully separated and quantified all five carbohydrates in four commercial infant milk powder samples with consistent results.
  • The use of amine-modified mobile phase significantly improved peak symmetry and retention of polar carbohydrates on the BEH HILIC column.