Skip to main content
QUICK REVIEW

[Paper Review] Determination of Chargino and Neutralino Masses in high-mass SUSY scenarios at CLIC

Natali Alster, M. Battaglia|arXiv (Cornell University)|Apr 4, 2011
Particle physics theoretical and experimental studiesPhysics and Astronomy12 references5 citations
TL;DR

This paper investigates the precision measurement of chargino and neutralino masses in high-mass supersymmetry scenarios at the CLIC e+e− collider using kinematic endpoints and threshold scans. It demonstrates that with 2 ab⁻¹ of integrated luminosity at √s = 3 TeV, mass accuracies of 0.8–1.7% (1.1–2.0%) are achievable for models with masses 600–900 GeV (>1000 GeV), respectively, after accounting for initial state radiation, beamstrahlung, and parton energy resolution, with threshold scans improving accuracy by a factor of two or more when combined with polarized beams.

ABSTRACT

This note reports the results of a study of the accuracy in the determination of chargino and neutralino masses in two high-mass supersymmetric scenarios through kinematic endpoints and threshold scans at a multi-TeV e+e- collider. The effects of initial state radiation, beamstrahlung and parton energy resolution are studied in fully hadronic final states of inclusive SUSY samples. Results obtained at generator level are compared to those from fully simulated and reconstructed events for selected channels.

Motivation & Objective

  • To evaluate the statistical accuracy in determining chargino and neutralino masses in high-mass SUSY scenarios at a multi-TeV e+e− collider.
  • To assess the impact of initial state radiation (ISR), beamstrahlung (BS), and parton energy resolution on mass measurement precision in fully hadronic final states.
  • To compare the performance of kinematic endpoint analysis and threshold scans for mass determination in inclusive SUSY samples.
  • To derive quantitative requirements on parton energy resolution that are complementary to those from other SUSY processes.
  • To evaluate the benefits of polarized beams in improving mass measurement accuracy despite radiation effects.

Proposed method

  • The study uses two constrained MSSM (cMSSM) benchmark models with high sparticle masses (Model I: 340–917 GeV; Model II: 554–1414 GeV) to simulate gaugino pair production at √s = 3 TeV.
  • Kinematic endpoint analysis is applied to the energy spectra of W±, Z⁰, and h⁰ bosons produced in two-body decays of charginos and neutralinos.
  • Threshold scans are performed around the production threshold to measure the derivative dσ/dm, optimizing luminosity distribution across a small number of scan points.
  • The analysis is conducted at generator level and validated using fully simulated and reconstructed events, including realistic detector effects and reconstruction efficiencies (~60% for four-jet final states).
  • Polarized beam configurations are tested to assess their impact on mitigating degradation from ISR and beamstrahlung.
  • A requirement of δE/E ≤ 0.05 for jet energy resolution is derived to ensure that resolution effects do not dominate over ISR and BS effects in mass uncertainty.

Experimental results

Research questions

  • RQ1What is the achievable statistical accuracy in measuring chargino and neutralino masses in high-mass SUSY scenarios at CLIC using kinematic endpoints?
  • RQ2How do initial state radiation and beamstrahlung degrade the precision of chargino and neutralino mass measurements in fully hadronic final states?
  • RQ3To what extent can threshold scans improve mass resolution compared to kinematic edge analysis in high-mass SUSY scenarios?
  • RQ4What is the required parton energy resolution to ensure that resolution effects do not dominate over radiation effects in mass measurements?
  • RQ5How effective are polarized beams in compensating for the loss of sensitivity due to ISR and beamstrahlung in threshold scans?

Key findings

  • For Model I (600–900 GeV sparticles), the relative mass accuracy after accounting for ISR, beamstrahlung, and energy resolution is 0.8% to 1.7% with 2 ab⁻¹ of integrated luminosity at √s = 3 TeV.
  • For Model II (>1000 GeV sparticles), the relative mass accuracy ranges from 1.1% to 2.0% under the same conditions.
  • Threshold scans improve mass accuracy by a factor of two or more compared to kinematic edge analysis, especially when luminosity is concentrated at the peak of sensitivity and near threshold.
  • The use of polarized beams further enhances accuracy, effectively compensating for ISR and beamstrahlung effects, particularly in models with larger production cross sections.
  • A parton energy resolution requirement of δE/E ≤ 0.05 is derived to ensure that resolution effects do not dominate the overall mass uncertainty.
  • The statistical uncertainty increases more significantly in Model I due to its larger distance from threshold, but absolute accuracy remains better due to higher cross sections.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.