[Paper Review] Development of a strategy for calibrating the novel SiPM camera of the SST-1M telescope proposed for the Cherenkov Telescope Array
This paper presents a fully automated, software-compatible calibration strategy for the novel SiPM camera of the SST-1M telescope in the Cherenkov Telescope Array (CTA), using a Camera Test Setup (CTS) with pulsed and continuous LED sources to calibrate single-pixel parameters such as gain, baseline, dark count rate, and crosstalk. The method achieves high precision with a 5.6 LSB/p.e. gain and 8% average crosstalk, validated via Monte Carlo simulations and real data, enabling robust large-scale production and online calibration for high-energy gamma-ray astronomy above 3 TeV.
CTA will comprise a sub-array of up to 70 small size telescopes (SSTs) at the southern array. The SST-1M project, a 4 m-diameter Davies Cotton telescope with 9 degrees FoV and a 1296 pixels SiPM camera, is designed to meet the requirements of the next generation ground based gamma-ray observatory CTA in the energy range above 3 TeV. Silicon photomultipliers (SiPM) cameras of gamma-ray telescopes can achieve good performance even during high night sky background conditions. Defining a fully automated calibration strategy of SiPM cameras is of great importance for large scale production validation and online calibration. The SST-1M sub-consortium developed a software compatible with CTA pipeline software (CTApipe). The calibration of the SST-1M camera is based on the Camera Test Setup (CTS), a set of LED boards mounted in front of the camera. The CTS LEDs are operated in pulsed or continuous mode to emulate signal and night sky background respectively. Continuous and pulsed light data analysis allows us to extract single pixel calibration parameters to be used during CTA operation.
Motivation & Objective
- To develop a scalable, automated calibration strategy for the SiPM camera of the SST-1M telescope in the Cherenkov Telescope Array (CTA).
- To ensure reliable single-pixel calibration under high night sky background (NSB) conditions using a dedicated test setup.
- To enable large-scale production validation and online calibration for up to 70 SST-1M telescopes in the southern CTA array.
- To characterize key camera parameters including gain, baseline, dark count rate, and crosstalk with high precision.
- To validate the calibration method using Monte Carlo simulations and real data from the CTS.
Proposed method
- The calibration strategy is implemented using a Camera Test Setup (CTS) with two LEDs per pixel: one pulsed (470 nm, 15° beam) and one continuous, mounted in front of the camera.
- Pulsed LED excitation enables measurement of the photoelectron (p.e.) spectrum and gain calibration via stacked multiple p.e. spectra.
- Continuous LED excitation emulates night sky background (NSB), allowing measurement of gain drop and baseline shift under varying light levels.
- The calibration pipeline is compatible with the CTA pipeline software (CTApipe), ensuring integration into the broader CTA data reduction framework.
- A generalized Poisson model with crosstalk probability is used to model SiPM response, improving accuracy over conventional methods.
- Monte Carlo simulations are used to study systematics, injecting dark counts and crosstalk to assess their impact on calibration parameters.
Experimental results
Research questions
- RQ1How can a fully automated, scalable calibration strategy be developed for the SiPM camera of the SST-1M telescope in the CTA?
- RQ2What is the impact of dark counts and crosstalk on the accuracy of gain, baseline, and noise measurements during calibration?
- RQ3How well does the generalized Poisson model with crosstalk probability describe the SiPM response compared to conventional methods?
- RQ4To what extent does the gain drop effect under increasing NSB levels affect calibration accuracy, and how can it be mitigated?
- RQ5How do systematics from signal reconstruction and unmodeled effects influence the final calibration parameters?
Key findings
- The calibration strategy achieves a gain of 5.6 LSB/p.e. with a width-to-gain ratio (σn/G) below 1, indicating high precision in gain measurement.
- The average crosstalk probability is measured at 8%, with the generalized Poisson model showing lower values than conventional methods, confirming improved accuracy.
- The microcell capacitance is measured at 84.44 fF, in excellent agreement with the Hamamatsu-provided value of 85 fF.
- The gain drop under NSB is reduced from 64% to 88% when replacing the 10 kΩ bias resistor with a 2.4 kΩ resistor, significantly improving performance during moonlit observations.
- Monte Carlo simulations show that dark counts and crosstalk have minimal impact on gain measurements but affect baseline and noise parameters, with pulls within 1σ error bars in most cases.
- The calibration pipeline, integrated with CTApipe, ensures compatibility and reproducibility across the CTA array, supporting large-scale deployment and online calibration.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.