This paper presents a bias-free method for extracting differential phase in atom gradiometers by correlating atomic interferometer signals with an auxiliary classical sensor (e.g., seismometer or accelerometer). The technique enables sensitivities approaching the quantum projection noise limit even under large vibration noise (exceeding 2π), provided the differential phase modulo π is zero, and works without prior knowledge of noise statistics or perfect signal correlation.
We present here a method for the extraction of the differential phase of an atom gradiometer that exploits the correlation of the vibration signal measured by an auxiliary classical sensor, such as a seismometer or an accelerometer. We show that sensitivities close to the quantum projection noise limit can be reached, even when the vibration noise induces phase fluctuations larger than 2$\\pi$. This method doesn't require the correlation between the atomic and classical signals to be perfect and allows for an exact determination of the differential phase, with no bias. It can also be applied to other configurations of differential interferometers, such as for instance gyrometers, conjugate interferometers for the measurement of the fine structure constant, or differential accelerometers for tests of the equivalence principle or detection of gravitational waves.
Motivation & Objective
- To address the challenge of extracting differential phase in atom gradiometers when vibration noise causes complete fringe washout in individual interferometers.
- To eliminate systematic biases in differential phase estimation that plague existing methods like fringe fitting or Bayesian estimators requiring noise models.
- To enable high-precision measurements in practical environments with strong mechanical noise, such as geophysical or space-based applications.
- To extend the method to other differential interferometer configurations, including gyrometers, conjugate interferometers for h/m measurements, and equivalence principle tests.
- To achieve sensitivity close to the quantum projection noise limit without requiring perfect correlation between atomic and classical signals.
Proposed method
- Use of an auxiliary classical sensor (e.g., seismometer or accelerometer) to measure mirror vibration phase φₘ, which correlates with the interferometer's phase fluctuations.
- Independent fitting of interferometer transition probabilities P₁ and P₂ as functions of the auxiliary sensor signal φₛ, enabling reconstruction of individual interferometer fringes despite large noise.
- Extraction of the differential phase φ_d = φ₂ − φ₁ + φ₂ₗ − φ₁ₗ by comparing the fitted phases of the two interferometers, leveraging their correlated noise response.
- Application of a robust three-dimensional fitting procedure to estimate φ_d from P₁(φₛ) and P₂(φₛ), with no need for a priori noise models or assumptions about phase distribution.
- Implementation of phase calibration via controlled phase jumps or magnetic pulses to set φ₁ + φ₁ₗ = 0, simplifying the differential phase to φ_d = φ₂ − φ₁ + φ₂ₗ − φ₁ₗ.
- Use of a rigidly coupled sensor to ensure high correlation between φₘ and φₛ, with signal processing to flatten the sensor’s transfer function for improved phase tracking.
Experimental results
Research questions
- RQ1Can differential phase be extracted from atom gradiometers with high vibration noise (σ_φₘ > 2π) without introducing bias?
- RQ2Does the correlation between atomic interferometer signals and a classical sensor’s output allow for sensitivity close to the quantum projection noise limit?
- RQ3How does the method perform when the correlation between the auxiliary sensor and mirror vibration is imperfect?
- RQ4Can the method be generalized to other differential interferometers such as gyrometers or accelerometers for equivalence principle tests?
- RQ5What is the impact of varying vibration noise amplitude on the differential phase estimation accuracy and sensitivity?
Key findings
- The method achieves differential phase extraction with no bias, regardless of noise amplitude or correlation quality, as long as the differential phase modulo π is zero.
- Sensitivity approaches the quantum projection noise limit even when mirror vibration noise σ_φₘ reaches 10 rad, corresponding to fringe washout in individual interferometers.
- For σ_φₘ = 10 rad and σ_δφ = 1 rad, the sensitivity is only twice the quantum projection noise limit, with vibration noise rejection exceeding a factor of 4000.
- The method remains stable and convergent for up to σ_δφ = 20 rad with 1000 fitting points, indicating robustness under high noise conditions.
- The differential phase extraction is insensitive to offsets A₁, A₂ and visibility amplitudes C₁, C₂, as long as the quantum projection noise limit is adjusted accordingly.
- The technique is applicable to other differential interferometers, including those using different atomic species or pulse sequences, where scale factors differ and vibration responses are non-identical.