TL;DR

This paper proposes an unsupervised, domain-knowledge-augmented method to detect and disaggregate Cumulative Water Heater (CWH) consumption from low-frequency (30-minute) smart meter data using temporal patterns and off-peak hour activation behavior. The model achieves precision and recall above 0.9 on ground truth data and successfully identifies CWHs in 85% of declared cases in a 5,000-home dataset, enabling detection of misconfigurations and performance degradation.

ABSTRACT

In this article we present an unsupervised low-frequency method aimed at detecting and disaggregating the power used by Cumulative Water Heaters (CWH) in residential homes. Our model circumvents the inherent difficulty of unsupervised signal disaggregation by using both the shape of a power spike and its time of occurrence to identify the contribution of CWH reliably. Indeed, many CHWs in France are configured to turn on automatically during off-peak hours only, and we are able to use this domain knowledge to aid peak identification despite the low sampling frequency. In order to test our model, we equipped a home with sensors to record the ground-truth consumption of a water heater. We then apply the model to a larger dataset of energy consumption of Hello Watt users consisting of one month of consumption data for 5k homes at 30-minute resolution. In this dataset we successfully identified CWHs in the majority of cases where consumers declared using them. The remaining part is likely due to possible misconfiguration of CWHs, since triggering them during off-peak hours requires specific wiring in the electrical panel of the house. Our model, despite its simplicity, offers promising applications: detection of mis-configured CWHs on off-peak contracts and slow performance degradation.

Motivation & Objective

  • To develop an unsupervised signal disaggregation method for Cumulative Water Heaters (CWHs) using low-frequency (30-minute) smart meter data.
  • To leverage domain-specific knowledge—specifically, the predictable activation of CWHs during off-peak hours in France—to improve detection accuracy despite low temporal resolution.
  • To validate the model on a ground-truth dataset from a single household and then scale it to a large anonymized dataset of ~5,000 homes.
  • To enable practical applications such as detecting misconfigured CWHs on off-peak contracts and monitoring long-term performance degradation.

Proposed method

  • The method identifies CWHs by detecting power spikes that occur consistently at the start of off-peak hours, leveraging known off-peak timing from the French smart meter system (Linky).
  • It uses local background consumption as a baseline to detect anomalous spikes, assuming CWHs activate reliably at off-peak onset.
  • The model relies on the temporal regularity of CWH activation—typically lasting 1.5 to 5 hours—ensuring spikes persist beyond the 30-minute sampling interval.
  • It assumes CWHs are connected to a pilot wire signal that triggers activation only during off-peak periods, which is a key domain constraint.
  • The method is unsupervised and does not require labeled training data, instead using temporal and behavioral priors from energy contracts and appliance behavior.
  • The model was first validated on a ground-truth dataset from one monitored household before being applied to a large-scale anonymized dataset of 5,000 homes.

Experimental results

Research questions

  • RQ1Can domain knowledge about off-peak hour activation be used to reliably detect CWHs in low-resolution (30-minute) smart meter data?
  • RQ2How accurately can an unsupervised method identify CWHs when only aggregate consumption data is available?
  • RQ3To what extent does the model detect CWHs in real-world homes where users report using electric water heaters?
  • RQ4What proportion of CWHs are misconfigured in terms of off-peak usage, and can the model detect such cases?
  • RQ5Can the model detect performance degradation or changes in CWH energy consumption over time?

Key findings

  • The model achieved precision and recall above 0.9 on the ground-truth dataset, confirming strong detection performance.
  • In the large-scale dataset of ~5,000 homes, the model successfully identified CWHs in the majority of cases where users declared using them.
  • The model detected CWHs with power levels ranging from 1 to 3.5 kW, consistent with typical CWH specifications.
  • The fraction of total household energy consumption attributed to CWHs ranged from 8% to 14%, aligning with national estimates of 12–15%.
  • The model identified potential misconfigurations in cases where CWHs were declared but did not show regular off-peak activation patterns.
  • The method is robust across sampling rates from 1 minute to 1 hour, suggesting broad applicability beyond 30-minute resolution.

Read this paper