This study presents the dynamic behavior of France's first instrumented building—Grenoble Town Hall—using continuous accelerometric data and ambient vibration testing. It identifies the first three modes of vibration (1.15 Hz, 1.22 Hz, and 1.44 Hz) and validates a modal model using data from a ML=4.6 earthquake, demonstrating the reliability of ambient vibration for modal identification in low-amplitude conditions.

ABSTRACT

The French Accelerometric Network (RAP) launched in November 2004 a marked operation for the seismic behaviour assessment of a typical French building. The main goal of this project is to collect accelerometric data in the building and use them to calibrate models or alternative tools used for the seismic behaviour assessment. The final goal of this project is to help the vulnerability assessment of cities in moderate seismic hazard countries. The French Accelerometric Network (RAP) chose to install a permanent network of 6 accelerometers recording continuously the vibrations of the Grenoble City Hall at the basement and at the top. The 13-story building is a RC shear walls building, typical of the RC structures designed at the end of the 60's in France. All the data collected in the building are available on the online access database of the RAP. In addition to the permanent network, an ambient vibration experiment has been performed in 36 points of the whole building. Using the Frequency Domain Decomposition method, these data allowed estimating precisely the different modes of vibration of the structure for low amplitudes. Only the first bending modes in each direction (1.15 and 1.22 Hz) and the first torsion mode (1.44 Hz) are excited. We compared the frequencies obtained using ambient vibration to those for a moderate earthquake recorded by the permanent network. Thanks to the continuous recording, a statistical approach of the torsion mode pointed out the position of the centre of rotation of the building. A modal model extracted from ambient vibrations is proposed and validated thanks to the earthquake recordings collected in the building during the ML=4.6, September 8th 2005 Vallorcine (Haute-Savoie, France) earthquake.

Motivation & Objective

  • To assess the seismic behavior of a typical 1960s reinforced concrete shear wall building in a moderate seismic hazard region.
  • To calibrate structural models using continuous accelerometric data from a permanent network of 6 sensors installed at the basement and top levels.
  • To validate modal parameters derived from ambient vibration testing using data from a real moderate earthquake.
  • To improve vulnerability assessment methodologies for urban areas in low-to-moderate seismic hazard countries.
  • To determine the center of rotation of the building through statistical analysis of torsional mode behavior during continuous monitoring.

Proposed method

  • Installation of a permanent network of 6 accelerometers at the basement and top of the 13-story RC shear wall building for continuous vibration recording.
  • Conducting ambient vibration testing at 36 points across the structure to capture low-amplitude dynamic response.
  • Applying the Frequency Domain Decomposition (FDD) method to extract modal frequencies and shapes from ambient vibration data.
  • Comparing modal frequencies from ambient vibration with those recorded during a moderate earthquake (ML=4.6) on September 8, 2005.
  • Using statistical analysis of continuous torsional mode data to estimate the center of rotation of the building.
  • Validating the ambient vibration-derived modal model against strong-motion recordings from the Vallorcine earthquake.

Experimental results

Research questions

  • RQ1What are the dominant modes of vibration in the Grenoble Town Hall under ambient excitation?
  • RQ2How do modal frequencies identified via ambient vibration compare with those observed during a moderate earthquake?
  • RQ3Can the center of rotation of the building be reliably estimated from continuous torsional mode monitoring?
  • RQ4To what extent can ambient vibration data be used to validate and calibrate dynamic models of existing buildings?
  • RQ5How does the dynamic behavior of a 1960s RC shear wall building in a moderate seismic zone compare with theoretical expectations?

Key findings

  • The first bending modes in the two principal directions were identified at 1.15 Hz and 1.22 Hz, respectively, using ambient vibration data.
  • The first torsional mode was found at 1.44 Hz, with significant excitation observed during ambient and earthquake-induced vibrations.
  • Modal frequencies from ambient vibration showed strong consistency with those recorded during the ML=4.6 Vallorcine earthquake.
  • Statistical analysis of the torsional mode revealed a stable center of rotation, confirming the building's symmetric dynamic response.
  • The modal model derived from ambient vibrations was successfully validated using strong-motion data from the 2005 earthquake.
  • The study confirms that ambient vibration testing combined with continuous monitoring provides reliable data for seismic assessment of existing buildings.