[Paper Review] Early Screening of SARS-CoV-2 by Intelligent Analysis of X-Ray Images
This study proposes a classical machine learning approach using Histogram of Oriented Gradients (HoG) and dimensionality reduction for early screening of SARS-CoV-2 from X-ray images. It achieves high accuracy (96%) and recall (98%) in distinguishing COVID-19 from normal, pneumonia, and non-COVID infiltration cases, outperforming deep learning methods and identifying non-COVID infiltration as the most radiologically similar to COVID-19, necessitating integration with clinical data for improved specificity.
Future SARS-CoV-2 virus outbreak COVID-XX might possibly occur during the next years. However the pathology in humans is so recent that many clinical aspects, like early detection of complications, side effects after recovery or early screening, are currently unknown. In spite of the number of cases of COVID-19, its rapid spread putting many sanitary systems in the edge of collapse has hindered proper collection and analysis of the data related to COVID-19 clinical aspects. We describe an interdisciplinary initiative that integrates clinical research, with image diagnostics and the use of new technologies such as artificial intelligence and radiomics with the aim of clarifying some of SARS-CoV-2 open questions. The whole initiative addresses 3 main points: 1) collection of standardize data including images, clinical data and analytics; 2) COVID-19 screening for its early diagnosis at primary care centers; 3) define radiomic signatures of COVID-19 evolution and associated pathologies for the early treatment of complications. In particular, in this paper we present a general overview of the project, the experimental design and first results of X-ray COVID-19 detection using a classic approach based on HoG and feature selection. Our experiments include a comparison to some recent methods for COVID-19 screening in X-Ray and an exploratory analysis of the feasibility of X-Ray COVID-19 screening. Results show that classic approaches can outperform deep-learning methods in this experimental setting, indicate the feasibility of early COVID-19 screening and that non-COVID infiltration is the group of patients most similar to COVID-19 in terms of radiological description of X-ray. Therefore, an efficient COVID-19 screening should be complemented with other clinical data to better discriminate these cases.
Motivation & Objective
- To develop an intelligent, low-cost X-ray screening system for early detection of SARS-CoV-2 using classical computer vision techniques.
- To evaluate the feasibility of early COVID-19 detection using standard X-ray imaging in primary care settings.
- To identify radiomic signatures and clinical confounders that affect diagnostic accuracy, particularly non-COVID-19 infiltrations.
- To compare classical machine learning approaches (HoG + feature selection) with state-of-the-art deep learning methods in COVID-19 detection.
- To assess the performance of the model across different stages of disease progression (early, mid, late) for early diagnosis potential.
Proposed method
- The method employs Histogram of Oriented Gradients (HoG) to extract texture and edge features from frontal-view posterior-anterior X-ray images.
- Dimensionality reduction is applied using DCV (Discriminant Component Variate) and other techniques to optimize feature space for classification.
- A two-stage classification pipeline is used: first, distinguishing between COVID-19, non-COVID-19 pneumonia, infiltration, and normal cases; second, assessing performance across disease stages.
- Model hyperparameters, including HoG cell size and reduction method, are tuned via statistical analysis of classification performance.
- The approach is evaluated using a dataset compiled from public repositories, with careful sampling to ensure balanced representation across classes.
- Performance is benchmarked against state-of-the-art deep learning methods using standard metrics: accuracy, sensitivity (recall), specificity, and precision.
Experimental results
Research questions
- RQ1Can a classical machine learning approach like HoG with dimensionality reduction outperform deep learning models in detecting SARS-CoV-2 from X-ray images?
- RQ2How does the model perform in distinguishing early-stage COVID-19 from other pulmonary pathologies, particularly non-COVID-19 infiltrations?
- RQ3What is the role of clinical data in reducing false positives caused by radiological similarities between non-COVID-19 infiltrations and COVID-19?
- RQ4Is there a significant difference in detection performance across early, mid, and late stages of COVID-19 pneumonia?
- RQ5Does including non-COVID-19 infiltration as a distinct class in training improve the model's specificity and clinical relevance?
Key findings
- The HoG-based method achieved 96% accuracy, 98% recall, and 96% precision in distinguishing COVID-19 from normal, pneumonia, and non-COVID-19 infiltration cases.
- The model outperformed multiple state-of-the-art deep learning methods in terms of specificity and precision, particularly in the two-class (COVID-19 vs. non-COVID-19) and three-class (COVID-19, pneumonia, normal) settings.
- Non-COVID-19 infiltration was identified as the most radiologically similar group to COVID-19, with over 20% of false positives in the system likely attributable to this class.
- There was no statistically significant difference in detection rates across early (89%), mid (93%), and late (94%) stages of disease, suggesting consistent performance regardless of progression stage.
- The study confirms the clinical feasibility of early COVID-19 screening using X-ray when combined with clinical variables, especially to filter out non-COVID-19 infiltrations.
- The use of DCV for dimensionality reduction and a HoG cell size of 16×16 pixels yielded the optimal model configuration based on statistical evaluation.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.