Skip to main content
QUICK REVIEW

[Paper Review] Electric dipole moment searches: Effect of linear electric field frequency shifts induced in confined gases, II

Robert Golub, Christopher Swank|ArXiv.org|Oct 29, 2008
Atomic and Subatomic Physics ResearchPhysics and Astronomy5 citations
TL;DR

This paper presents an analytic solution for linear electric field frequency shifts in neutron electric dipole moment (EDM) searches due to motional magnetic fields and magnetic field gradients in rectangular storage vessels. It shows that in non-cylindrical geometries, the frequency shift depends on separate transverse gradients ∂Bₓ/∂x and ∂Bᵧ/∂y rather than ∂B_z/∂z, with key implications for systematic error control in the LANL SNS neutron EDM experiment using ³He co-magnetometers.

ABSTRACT

The next generation of particle edm searches will be at such a high sensitivity that it will be possible for the results to be contaminated by a systematic error resulting from the interaction of the motional (E x v/c) magnetic field with stray field gradients. In this paper we extend previous work to present an analytic form for the frequency shift in the case of a rectangular storage vessel and discuss the implications of the result for the neutron edm experiment which will be installed at the SNS (Spallation Neutron Source) by the LANL collaboration

Motivation & Objective

  • To address systematic errors in next-generation neutron electric dipole moment (EDM) searches arising from the interaction of motional magnetic fields (E×v/c) with magnetic field gradients.
  • To extend prior work on cylindrical containers to rectangular geometries, which are more representative of actual experimental setups like the SNS neutron EDM experiment.
  • To derive an analytic expression for the frequency shift in a rectangular box with specular reflecting walls, enabling precise modeling of systematic effects.
  • To quantify how deviations from cylindrical symmetry—specifically unequal wall dimensions—affect the frequency shift and thus the sensitivity of EDM measurements.
  • To validate the theoretical model against numerical simulations, ensuring accuracy for use in real experimental designs.

Proposed method

  • Derives the velocity autocorrelation function (VACF) for particles in a rectangular box with specular reflections, assuming constant velocity components between collisions.
  • Uses the VACF to compute the spectral function Sᵢ(ω₀) via Fourier transform, which enters the frequency shift formula ΔΩ_E ∝ ∂Bᵢ/∂xᵢ × Sᵢ(ω₀).
  • Applies the general frequency shift formula ΔΩ_E = -γ²E/(2c) [ (∂B_y/∂y)S_y(ω₀) + (∂B_x/∂x)S_x(ω₀) ] to rectangular geometry, accounting for independent motion in x and y directions.
  • Averages the frequency shift over a Maxwell-Boltzmann velocity distribution to model thermalized particles, relevant for ³He co-magnetometers in superfluid ⁴He.
  • Compares theoretical predictions with numerical simulations of particle trajectories, confirming consistency in the high-frequency and low-temperature regimes.
  • Considers the role of detailed balance and trajectory averaging to reconcile differences between theoretical VACF (based on single trajectories) and simulation-based VACF (with collision-induced direction changes).

Experimental results

Research questions

  • RQ1How does the frequency shift from motional magnetic fields depend on the geometry of a rectangular storage vessel in neutron EDM experiments?
  • RQ2What is the analytic form of the frequency shift in a rectangular box with specular reflecting walls, and how does it differ from the cylindrical case?
  • RQ3To what extent do transverse magnetic field gradients ∂Bₓ/∂x and ∂Bᵧ/∂y contribute independently to the systematic shift, rather than only ∂B_z/∂z?
  • RQ4How do thermal effects and velocity distributions affect the frequency shift in realistic experimental conditions?
  • RQ5How well do theoretical predictions of the frequency shift match numerical simulations of particle trajectories in a rectangular box?

Key findings

  • The frequency shift in a rectangular box depends on separate transverse gradients ∂Bₓ/∂x and ∂Bᵧ/∂y, breaking the cylindrical symmetry that reduces the shift to dependence on ∂B_z/∂z alone.
  • For a rectangular box with L_y/L_x = 0.2, the x-direction contribution dominates the frequency shift at low frequencies, while the y-direction contribution is smaller but non-negligible.
  • The theoretical prediction for the frequency shift matches numerical simulations within statistical uncertainty, validating the analytic approach.
  • At high frequencies (ω₀ ≫ ωᵣ), the difference between S_x(ω₀) and S_y(ω₀) vanishes, restoring the cylindrical symmetry limit.
  • The results show that systematic errors from motional fields are sensitive to geometric asymmetry, necessitating careful control of magnetic field gradients in non-cylindrical traps.
  • The study confirms that averaging over all trajectories ensures consistency between theoretical VACF and simulation-based results, despite differences in collision handling.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.