Skip to main content
QUICK REVIEW

[Paper Review] Electric Vehicle Charging Station Placement Method for Urban Areas

Qiushi Cui, Yang Weng|arXiv (Cornell University)|Aug 29, 2018
Electric Vehicles and InfrastructureEngineering18 references5 citations
TL;DR

This paper proposes a convexified mixed-integer linear programming model for optimal electric vehicle (EV) charging station placement in urban areas, integrating voltage regulation and protective device upgrade costs. By preserving problem convexity through sequential constraint convexification, the method guarantees global optimality and reveals that protective device upgrades can account for up to 8.6% of total planning costs, highlighting their critical role in urban grid planning.

ABSTRACT

For accommodating more electric vehicles (EVs) to battle against fossil fuel emission, the problem of charging station placement is inevitable and could be costly if done improperly. Some researches consider a general setup, using conditions such as driving ranges for planning. However, most of the EV growths in the next decades will happen in the urban area, where driving ranges is not the biggest concern. For such a need, we consider several practical aspects of urban systems, such as voltage regulation cost and protection device upgrade resulting from the large integration of EVs. Notably, our diversified objective can reveal the trade-off between different factors in different cities worldwide. To understand the global optimum of large-scale analysis, we add constraint one-by-one to see how to preserve the problem convexity. Our sensitivity analysis before and after convexification shows that our approach is not only universally applicable but also has a small approximation error for prioritizing the most urgent constraint in a specific setup. Finally, numerical results demonstrate the trade-off, the relationship between different factors and the global objective, and the small approximation error. A unique observation in this study shows the importance of incorporating the protection device upgrade in urban system planning on charging stations.

Motivation & Objective

  • To address the growing need for efficient EV charging infrastructure in urban areas, where driving range is less of a constraint than in intercity settings.
  • To incorporate previously overlooked costs—particularly protective device upgrades and voltage regulation—into EV charging station placement optimization.
  • To develop a convex optimization framework that guarantees global optimality while maintaining sensitivity to key system constraints.
  • To validate the method’s robustness and applicability across diverse urban distribution networks through comprehensive sensitivity and numerical analysis.

Proposed method

  • The study formulates a mixed-integer linear programming (MILP) problem that integrates distribution network expansion, EV station, voltage regulation, and protective device upgrade costs into a unified objective function.
  • It introduces step-function modeling of protective device costs based on fault current levels and device type, enabling accurate cost representation in the optimization.
  • The method applies sequential convexification to non-convex constraints, preserving problem sensitivity and ensuring global optimality through convex relaxation techniques.
  • The AC power flow equations are linearized using a ZIP load model and nodal admittance matrix formulation, enabling tractable solution of power flow constraints.
  • Sensitivity analysis is conducted both before and after convexification to validate the method’s robustness and applicability across different urban network configurations.
  • The approach is tested on 18-bus, 115-bus, and 123-bus distribution systems under varying EV flow rates and station capacity constraints.

Experimental results

Research questions

  • RQ1How do protective device upgrade costs influence the optimal placement of EV charging stations in urban distribution networks?
  • RQ2To what extent does including voltage regulation and protective device costs alter the optimal charging station configuration compared to models that ignore these factors?
  • RQ3Can the proposed convexification strategy preserve the sensitivity of the optimization problem while guaranteeing global optimality?
  • RQ4What is the quantitative impact of protective device upgrades on the total planning cost in real-world urban distribution systems?
  • RQ5How scalable and transferable is the proposed method across different urban network sizes and configurations?

Key findings

  • Protective device upgrade costs can constitute up to 8.6% of the total planning cost in urban distribution networks, making them a non-negligible factor in EV infrastructure planning.
  • The proposed convexification method maintains problem sensitivity and guarantees global optimality, with minimal approximation error in numerical evaluations.
  • Voltage regulation costs favor placing charging stations at the ends of distribution feeders, while protective device costs favor placement along main feeder lines to reduce fault current levels.
  • In the 115-bus system, with 1,500 EVs per hour and 30% station utilization, 39 stations were optimally placed at a total cost of $18.6 million, with protective device costs accounting for 8.6% of the total.
  • The method demonstrates strong scalability and adaptability, remaining effective across diverse urban network sizes, including 18-bus, 115-bus, and 123-bus systems.
  • The computational time is significantly reduced due to convexity preservation, enabling efficient large-scale deployment of the optimization framework.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.