Skip to main content
QUICK REVIEW

[Paper Review] Electromagnetically induced transparency based Rydberg-atom sensor for quantum voltage measurements

Christopher L. Holloway, Nikunjkumar Prajapati|arXiv (Cornell University)|Oct 5, 2021
Advanced Frequency and Time StandardsPhysics and Astronomy18 references4 citations
TL;DR

This paper proposes a Rydberg-atom-based sensor using electromagnetically induced transparency (EIT) to measure dc and 60 Hz ac voltages with quantum precision. By detecting Stark shifts in Rydberg rubidium atoms, the method achieves voltage measurements with fractional uncertainty around 0.01 V/V and sensitivity of 0.007 V/V Hz⁻¹ᐟ², offering a compact, low-cost alternative to Josephson voltage standards and Zener diodes.

ABSTRACT

We investigate the Stark shift in Rydberg rubidium atoms through electromagnetically induced transparency for the measurement of direct current (dc) and 60~Hz alternating current (ac) voltages. This technique has direct applications to atom-based measurements of dc and ac voltage and the calibration of voltage instrumentation. We present experimental results for different atomic states that allow for dc and ac voltage measurements ranging from 0~V to 12~V. A Rydberg atom-based voltage standard could become an alternative calibration method with more favorable size, weight, power consumption, and cost compared to the more precise Josephson voltage standard. In this study, we also demonstrate how the voltage measurements can be utilized to determine the atomic polarizability for the Rydberg states. The Rydberg atom-based voltage measurement technology would become a complimentary method for dissemination of the voltage scale directly to the end user.

Motivation & Objective

  • To develop a compact, low-power alternative to Josephson voltage standards for voltage calibration.
  • To demonstrate quantum-based voltage measurement using Stark shifts in Rydberg rubidium atoms via electromagnetically induced transparency (EIT).
  • To calibrate voltage measurements using atomic polarizability and plate separation, enabling traceability to fundamental constants.
  • To address practical challenges such as inhomogeneous electric fields, electrode non-uniformities, and energy level crossings for reliable operation.
  • To enable direct dissemination of the voltage scale to end users through a self-calibrating, deployable sensor.

Proposed method

  • Measure Stark shifts in Rydberg rubidium atoms (47S and 28S states) using EIT under applied electric fields from parallel-plate electrodes.
  • Use a laser sweep spanning several GHz to probe EIT line shapes and extract Stark shift (Δ) from peak frequency shifts.
  • Construct calibration curves by measuring Δ at known voltages (0–12 V) to relate shift to voltage.
  • Apply quadratic fitting to account for energy level crossings (ELCs) and improve accuracy at higher voltages.
  • Utilize EIT linewidth and peak amplitude to determine voltage sensitivity, limited currently to 15 MHz linewidth.
  • Estimate polarizability and plate separation from calibration data, enabling future self-calibrating devices.
Figure 1: Cylindrical vapor cell with stainless-steel parallel plates. The vapor cell is 50 mm in length and has a outside diameter of 25 mm. The plates are rectangular in shape with width of 18 mm, length of 45 mm, and placed $\approx 2$ mm apart.
Figure 1: Cylindrical vapor cell with stainless-steel parallel plates. The vapor cell is 50 mm in length and has a outside diameter of 25 mm. The plates are rectangular in shape with width of 18 mm, length of 45 mm, and placed $\approx 2$ mm apart.

Experimental results

Research questions

  • RQ1Can Rydberg-atom EIT sensors achieve accurate dc voltage measurements across 0–12 V with fractional uncertainty below 0.01 V/V?
  • RQ2How do inhomogeneous electric fields and electrode imperfections affect EIT line shape and voltage measurement accuracy?
  • RQ3To what extent can the 60 Hz ac voltage amplitude be measured with minimal apparatus modification?
  • RQ4What is the achievable voltage sensitivity in terms of V/V Hz⁻¹ᐟ² using Rydberg states like 47S and 28S?
  • RQ5Can atomic polarizability and plate separation be accurately determined from calibration data to enable self-calibrating voltage sensors?

Key findings

  • The voltage measurement achieved an average fractional uncertainty of 0.01 V/V over the 0–12 V range, with uncertainty remaining constant due to EIT peak broadening at higher voltages.
  • The sensitivity of the voltage measurement reached 0.007 V/V Hz⁻¹ᐟ² using the 47S Rydberg state, improving to 0.003 V/V Hz⁻¹ᐟ² with the 28S state due to stronger EIT peaks.
  • The measured Stark shift uncertainty translated to a voltage uncertainty of ±5 MHz on average across six data sets, with consistent calibration performance.
  • Polarizability for the Rydberg states was determined from calibration data, enabling future direct traceability to fundamental constants.
  • Plate separation was estimated to within 10s of microns using calibration factors, demonstrating feasibility for precise sensor design.
  • The method enabled ac voltage measurement at 60 Hz with minimal apparatus changes, validating its practicality for real-world deployment.
Figure 2: Calculated dc Stark shift $\Delta_{f}$ in 85 Rb as a function of electric field $E$ for $40S$ and $40D$ .
Figure 2: Calculated dc Stark shift $\Delta_{f}$ in 85 Rb as a function of electric field $E$ for $40S$ and $40D$ .

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.