Skip to main content
QUICK REVIEW

[Paper Review] Emulator-based Bayesian Inference on Non-Proportional Scintillation Models by Compton-Edge Probing

David Breitenmoser, F. Cerutti|arXiv (Cornell University)|Feb 11, 2023
Radiation Detection and Scintillator TechnologiesPhysics and Astronomy1 citations
TL;DR

This paper presents a novel emulator-based Bayesian inference framework using Compton-edge probing to calibrate non-proportional scintillation models (NPSM) in inorganic scintillators like NaI(Tl), eliminating the need for electron beam or K-dip measurements. By combining laboratory gamma-ray spectrometry with Markov Chain Monte Carlo (MCMC) Bayesian inversion and machine learning emulators of Monte Carlo simulations, the method accurately infers NPSM parameters and quantifies intrinsic energy resolution with 95% credible intervals.

ABSTRACT

Scintillator detector response modelling has become an essential tool in various research fields such as particle and nuclear physics, astronomy or geophysics. Yet, due to the system complexity and the requirement for accurate electron response measurements, model inference and calibration remains a challenge. Here, we propose Compton edge probing to perform non-proportional scintillation model (NPSM) inference for inorganic scintillators. We use laboratory-based gamma-ray radiation measurements with a NaI(Tl) scintillator to perform Bayesian inference on a NPSM. Further, we apply machine learning to emulate the detector response obtained by Monte Carlo simulations. We show that the proposed methodology successfully constrains the NPSM and hereby quantifies the intrinsic resolution. Moreover, using the trained emulators, we can predict the spectral Compton edge dynamics as a function of the parameterized scintillation mechanisms. The presented framework offers a novel way to infer NPSMs for any inorganic scintillator without the need for additional electron response measurements.

Motivation & Objective

  • Address the challenge of calibrating non-proportional scintillation models (NPSM) in inorganic scintillators, which are critical for accurate gamma-ray spectrometry but difficult to calibrate with existing methods.
  • Overcome the limitations of current NPSM calibration techniques—such as K-dip spectroscopy and electron beam measurements—that require specialized equipment and are not feasible for in-situ or mission-critical applications.
  • Develop a scalable, non-invasive method to infer NPSM parameters using only standard gamma-ray spectrometry data from laboratory sources.
  • Enable accurate prediction of Compton edge dynamics as a function of scintillation mechanisms, improving spectral response modeling for applications in particle physics, astronomy, and space missions.

Proposed method

  • Perform laboratory-based gamma-ray spectrometry using calibrated radionuclide sources and a NaI(Tl) scintillator to collect Compton edge spectral data.
  • Use a multi-purpose Monte Carlo code (FLUKA) to simulate detector responses with a non-proportional scintillation model (NPSM) that includes energy loss dependencies on electron stopping power and carrier trapping.
  • Train machine learning emulators (surrogate models) on the Monte Carlo simulation data to accelerate the forward modeling required for Bayesian inference.
  • Apply Bayesian inversion with Markov Chain Monte Carlo (MCMC) algorithms to infer posterior distributions of NPSM parameters, including dE/ds |Birks, dE/ds |Trap, ηe/h, and discrepancy variance σ²ε.
  • Incorporate empirical resolution parameters (B₁*, B₂, D₁) and prior distributions to account for systematic uncertainties in the calibration process.
  • Use Compton edge position and shape as the primary observables to constrain the NPSM, leveraging the known sensitivity of the Compton edge to non-proportional scintillation.

Experimental results

Research questions

  • RQ1Can Compton edge probing in gamma-ray spectrometry be used as a viable alternative to electron beam or K-dip measurements for calibrating non-proportional scintillation models?
  • RQ2To what extent can machine learning emulators of Monte Carlo simulations replace full simulations in Bayesian inference for NPSM calibration?
  • RQ3How accurately can Bayesian inference with MCMC quantify the uncertainty in NPSM parameters such as stopping power and carrier fraction?
  • RQ4What is the impact of NPSM parameters on the predicted Compton edge dynamics, and can these be reliably predicted without direct electron response measurements?
  • RQ5Can the proposed framework be generalized to other inorganic scintillators without requiring additional experimental calibration data?

Key findings

  • The method successfully constrains the NPSM parameters with 95% credible intervals, yielding dE/ds |Birks = 3.10 × 10² MeV cm⁻¹ (95% CI: [2.79, 3.48] × 10² MeV cm⁻¹) and dE/ds |Trap = 1.46 × 10¹ MeV cm⁻¹ (95% CI: [1.33, 1.50] × 10¹ MeV cm⁻¹) under a 2.5% energy scale uncertainty.
  • The free carrier fraction ηe/h is inferred as 5.92 × 10⁻¹ with a 95% credible interval of [5.82, 6.01] × 10⁻¹, indicating a high degree of electron transport efficiency.
  • The discrepancy model variance σ²ε is estimated at 1.12 × 10⁻¹ cps² Bq⁻² (95% CI: [0.89, 1.56] × 10⁻¹ cps² Bq⁻²), reflecting the uncertainty in the measurement-model mismatch.
  • The trained emulators enable fast and accurate prediction of Compton edge dynamics across parameter space, reducing computational cost by orders of magnitude compared to full Monte Carlo simulations.
  • The framework achieves consistent calibration results across multiple NaI(Tl) crystals, with empirical resolution parameters (B₁*, B₂, D₁) showing low inter-crystal variability and well-defined Gaussian priors.
  • The approach is robust under energy scale variations, with parameter estimates remaining stable under ±2.5% shifts in the energy deposition scale, demonstrating practical feasibility for real-world applications.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.