[Paper Review] Epidemiological short-term Forecasting with Model Reduction of Parametric Compartmental Models. Application to the first pandemic wave of COVID-19 in France
This paper proposes a model order reduction approach for short-term epidemiological forecasting using time-dependent SIR models with reduced-parameter bases. By learning low-dimensional manifolds of transmission ($\beta$) and recovery ($\gamma$) rates from synthetic epidemic scenarios, the method enables accurate two-week forecasts of infected and removed cases in France during the first two COVID-19 waves, with the Eikonal-based Non-negative Greedy (ENG) reduced basis outperforming SVD and NMF in robustness and accuracy.
We propose a forecasting method for predicting epidemiological health series on a two-week horizon at the regional and interregional resolution. The approach is based on model order reduction of parametric compartmental models, and is designed to accommodate small amount of sanitary data. The efficiency of the method is shown in the case of the prediction of the number of infected and removed people during the two pandemic waves of COVID-19 in France, which have taken place approximately between February and November 2020. Numerical results illustrate the promising potential of the approach.
Motivation & Objective
- Address the challenge of short-term epidemiological forecasting during pandemics with limited and noisy health data.
- Overcome the high uncertainty in estimating parameters of traditional compartmental models, especially for new diseases like SARS-CoV-2.
- Develop a forecasting framework that balances fitting accuracy and predictive power by reducing model complexity.
- Enable regional and interregional forecasting at a two-week horizon using only hospitalization data and an adjustment factor for asymptomatic cases.
- Demonstrate the method’s effectiveness on real data from France’s first two pandemic waves (Feb–Nov 2020).
Proposed method
- Use a parametric SIR model with time-dependent transmission ($\beta(t)$) and recovery ($\gamma(t)$) rates to exactly fit observed data over a training window $[0,T]$.
- Generate a large ensemble of virtual epidemic scenarios using uniformly sampled parameter configurations over a longer time interval $[0,T+\tau]$ to learn the dynamics of $\beta(t)$ and $\gamma(t)$.
- Apply model order reduction techniques—Singular Value Decomposition (SVD), Non-negative Matrix Factorization (NMF), and Eikonal-based Non-negative Greedy (ENG)—to construct low-dimensional reduced bases for $\beta$ and $\gamma$.
- Project the observed data onto the reduced basis to find the best-fitting $\beta_n^*(t)$ and $\gamma_n^*(t)$ functions over $[0,T]$.
- Use the extended time horizon $[0,T+\tau]$ of the reduced basis to generate forecasts from $T$ to $T+\tau$, with $\tau=14$ days.
- Evaluate forecasting performance using $L^1$ and $L^\infty$ relative errors on infected ($I$) and removed ($R$) populations.

Experimental results
Research questions
- RQ1Can a reduced-order model of time-varying SIR parameters achieve accurate short-term forecasting with minimal data?
- RQ2How do different model order reduction techniques—SVD, NMF, and ENG—compare in fitting and forecasting performance?
- RQ3Does the choice of fitting routine (routine-IR vs. routine-$\bm{\beta\gamma}$) affect forecasting robustness and accuracy?
- RQ4How sensitive is the forecasting error to the starting date $T$ of the forecast window?
- RQ5Can the method reliably forecast regional and interregional trends during the early stages of a pandemic with limited surveillance data?
Key findings
- The Eikonal-based Non-negative Greedy (ENG) reduced basis consistently outperformed SVD and NMF in both fitting and forecasting accuracy across all tested scenarios.
- Forecasting errors using routine-$\bm{\beta\gamma}$ with ENG reduced bases were the lowest and most stable, with $L^1$ relative errors on $I$ below $10^{-2}$ and $L^\infty$ errors on $R$ below $10^{-3}$ for $n=2$ to $n=7$.
- SVD-based forecasts showed moderate error decay with increasing basis dimension $n$, but errors remained above $10^{-4}$ for $I$ and $10^{-5}$ for $R$ even at $n=20$.
- NMF-based methods exhibited oscillating fitting errors around $10^{-1}$ for $\beta$ and $\gamma$, yet produced relatively low forecasting errors on $I$ and $R$ due to inherent regularization.
- Forecasts using routine-IR with SVD and NMF were more robust than those with routine-$\bm{\beta\gamma}$, which suffered from error explosion in some cases.
- The forecasting performance strongly depended on the starting date $T$, with earlier forecasts (e.g., $T=01/04$) showing higher error variability than later ones (e.g., $T=05/05$).

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.