Skip to main content
QUICK REVIEW

[Paper Review] Evaluation of an AI System for the Detection of Diabetic Retinopathy from Images Captured with a Handheld Portable Fundus Camera: the MAILOR AI study

Thomas W. Rogers, J. Gonzalez-Bueno|arXiv (Cornell University)|Aug 18, 2019
Retinal Imaging and AnalysisMedicine7 references4 citations
TL;DR

This study evaluates the Pegasus AI system for detecting diabetic retinopathy (DR) using images from a handheld portable fundus camera in a real-world clinical setting. While the AI showed strong performance for proliferative DR (AUROC 94.3%), its accuracy for referable DR dropped significantly compared to a benchmark desktop dataset (AUROC 89.4% vs. 98.5%), indicating reduced transferability for less severe DR stages in mobile imaging settings.

ABSTRACT

Objectives: To evaluate the performance of an Artificial Intelligence (AI) system (Pegasus, Visulytix Ltd., UK), at the detection of Diabetic Retinopathy (DR) from images captured by a handheld portable fundus camera. Methods: A cohort of 6,404 patients (~80% with diabetes mellitus) was screened for retinal diseases using a handheld portable fundus camera (Pictor Plus, Volk Optical Inc., USA) at the Mexican Advanced Imaging Laboratory for Ocular Research. The images were graded for DR by specialists according to the Scottish DR grading scheme. The performance of the AI system was evaluated, retrospectively, in assessing Referable DR (RDR) and Proliferative DR (PDR) and compared to the performance on a publicly available desktop camera benchmark dataset. Results: For RDR detection, Pegasus performed with an 89.4% (95% CI: 88.0-90.7) Area Under the Receiver Operating Characteristic (AUROC) curve for the MAILOR cohort, compared to an AUROC of 98.5% (95% CI: 97.8-99.2) on the benchmark dataset. This difference was statistically significant. Moreover, no statistically significant difference was found in performance for PDR detection with Pegasus achieving an AUROC of 94.3% (95% CI: 91.0-96.9) on the MAILOR cohort and 92.2% (95% CI: 89.4-94.8) on the benchmark dataset. Conclusions: Pegasus showed good transferability for the detection of PDR from a curated desktop fundus camera dataset to real-world clinical practice with a handheld portable fundus camera. However, there was a substantial, and statistically significant, decrease in the diagnostic performance for RDR when using the handheld device.

Motivation & Objective

  • To assess the diagnostic performance of an AI system (Pegasus) in detecting diabetic retinopathy from images captured with a handheld portable fundus camera.
  • To compare the AI's performance on real-world handheld camera data against a publicly available benchmark dataset from desktop fundus cameras.
  • To evaluate the system's transferability from controlled benchmark conditions to real-world clinical practice.
  • To determine whether the AI maintains high sensitivity and specificity for referable DR (RDR) and proliferative DR (PDR) in a diverse patient cohort.

Proposed method

  • A cohort of 6,404 patients, ~80% with diabetes mellitus, was screened using a handheld portable fundus camera (Pictor Plus).
  • Retinal images were graded for DR by specialists using the Scottish DR grading scheme as the reference standard.
  • The Pegasus AI system was retrospectively evaluated on its ability to detect referable DR (RDR) and proliferative DR (PDR) from the same images.
  • Performance was measured using the Area Under the Receiver Operating Characteristic curve (AUROC), with 95% confidence intervals reported.
  • The AI’s performance on the MAILOR cohort was compared directly to its performance on a publicly available benchmark dataset from desktop fundus cameras.
  • Statistical significance was assessed to determine differences in diagnostic accuracy between the two imaging settings.

Experimental results

Research questions

  • RQ1How does the Pegasus AI system perform in detecting referable diabetic retinopathy (RDR) when using images from a handheld portable fundus camera compared to a benchmark desktop camera dataset?
  • RQ2Does the AI system maintain high diagnostic accuracy for proliferative diabetic retinopathy (PDR) in real-world clinical settings using handheld devices?
  • RQ3Is there a statistically significant difference in the AI’s diagnostic performance between handheld and desktop fundus camera imaging modalities?
  • RQ4To what extent does the AI system’s performance transfer from controlled benchmark environments to real-world clinical practice?

Key findings

  • The Pegasus AI system achieved an AUROC of 89.4% (95% CI: 88.0–90.7) for referable DR (RDR) detection in the MAILOR cohort using images from a handheld portable fundus camera.
  • This performance was significantly lower than the AUROC of 98.5% (95% CI: 97.8–99.2) achieved by the same AI system on a publicly available benchmark dataset from desktop fundus cameras.
  • For proliferative DR (PDR) detection, the AI achieved an AUROC of 94.3% (95% CI: 91.0–96.9) in the MAILOR cohort, showing strong diagnostic performance.
  • No statistically significant difference was found in PDR detection performance between the MAILOR cohort and the benchmark dataset (AUROC 92.2% on the benchmark, 95% CI: 89.4–94.8).
  • The study found a substantial and statistically significant decrease in diagnostic accuracy for RDR when transitioning from desktop to handheld fundus camera imaging.
  • The results indicate good transferability of the AI system for PDR detection but limited transferability for RDR detection when using handheld devices in real-world clinical settings.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.