This study evaluates the in-situ performance of EJ-426 scintillator-based neutron detectors with Hamamatsu PMTs in a harsh mixed-field radiation environment near spent nuclear fuel at CLAB, Sweden. Over eight months, detectors accumulated 35 kGy dose, showing ~30% reduction in neutron detection efficiency due to PMT window browning and gain loss, which was partially compensated by increasing high voltage, demonstrating feasibility for long-term non-destructive spent fuel characterization.
The reliable detection of neutrons in a harsh gamma-ray environment is an important aspect of establishing non-destructive methods for the characterization of spent nuclear fuel. In this study, we present results from extended in-situ monitoring of detector systems consisting of commercially available components: EJ-426, a $^6$Li-enriched solid-state scintillator material sensitive to thermal neutrons, and two different types of Hamamatsu photomultiplier tubes (PMT). Over the period of eight months, these detectors were operated in close vicinity to spent nuclear fuel stored at the interim storage facility CLAB, Oskarshamn, Sweden. At the measurement position the detectors were continuously exposed to an estimated neutron flux of approx. 280 n/s $\cdot$ cm$^2$ and a gamma-ray dose rate of approx. 6 Sv/h. Using offline software algorithms, neutron pulses were identified in the data. Over the entire investigated dose range of up to 35 kGr, the detector systems were functioning and were delivering detectable neutron signals. Their performance as measured by the number of identified neutrons degrades down to about 30% of the initial value. Investigations of the irradiated components suggest that this degradation is a result of reduced optical transparency of the involved materials as well as a reduction of PMT gain due to the continuous high currents. Increasing the gain of the PMT through step-ups of the applied high voltage allowed to partially compensate for this loss in detection sensitivity. The integrated neutron fluence during the measurement was experimentally verified to be in the order of $5 \cdot 10^9$ n/cm$^2$. The results were interpreted with the help of MCNP6.2 simulations of the setup and the neutron flux.
Motivation & Objective
- To assess the long-term radiation hardness of commercial EJ-426 scintillator neutron detectors in a real spent fuel storage environment.
- To evaluate the performance degradation of neutron detection under high gamma-ray dose rates (~6 Sv/h) and neutron flux (~280 n/s cm²).
- To distinguish between scintillator and PMT degradation mechanisms in mixed-field radiation.
- To validate the feasibility of using non-3He neutron detectors for long-term, in-situ spent fuel characterization in future encapsulation facilities.
Proposed method
- Deployed EJ-426 scintillator screens coupled to two types of Hamamatsu PMTs (silica and borosilicate glass) in proximity to spent fuel at CLAB.
- Conducted continuous in-situ monitoring for eight months under high-dose mixed-field conditions (gamma: ~6 Sv/h, neutrons: ~280 n/s cm²).
- Used offline software algorithms to identify and characterize neutron pulses based on pulse shape and amplitude.
- Performed post-irradiation analysis on components, including optical transparency measurements and PMT gain testing.
- Conducted controlled measurements with an Am/Be source before and after irradiation to compare signal amplitude distributions.
- Validated integrated neutron fluence using MCNP6.2 simulations of the experimental setup.
Experimental results
Research questions
- RQ1How does prolonged exposure to a mixed-field radiation environment (gamma and neutrons) affect the neutron detection efficiency of EJ-426 scintillator-based detectors?
- RQ2What are the dominant degradation mechanisms in EJ-426 scintillators and PMTs under high-dose gamma irradiation (up to 35 kGy)?
- RQ3Can the performance degradation of neutron detectors be mitigated by adjusting the high voltage applied to the PMT?
- RQ4To what extent does the optical transparency of the scintillator and PMT window material degrade after irradiation, and how does this affect signal amplitude?
- RQ5Can the detector system maintain reliable neutron detection over extended periods in a high-background, high-dose environment typical of spent fuel encapsulation facilities?
Key findings
- The EJ-426/QRZ detector (silica glass PMT) showed a 30% reduction in neutron detection efficiency after 35 kGy dose, primarily due to PMT gain loss from high anode current.
- The EJ-426/BSG detector (borosilicate glass PMT) exhibited more severe degradation, with signal amplitude reduced due to browning of the PMT window and gain loss.
- Increasing the high voltage applied to the PMT partially restored detection sensitivity, especially in the EJ-426/BSG configuration.
- The optical transparency of the irradiated EJ-426 scintillator decreased due to discoloration, contributing to reduced light collection and signal amplitude.
- The integrated neutron fluence was experimentally verified to be approximately 5 × 10⁹ n cm⁻², consistent with MCNP6.2 simulations.
- The system achieved over 95% uptime with remote operation via USB thumb drive, demonstrating robustness for autonomous long-term deployment.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.