Skip to main content
QUICK REVIEW

[Paper Review] Event Camera Calibration of Per-pixel Biased Contrast Threshold

Ziwei Wang, Yonhon Ng|arXiv (Cornell University)|Dec 17, 2020
Advanced Memory and Neural ComputingEngineering30 references14 citations
TL;DR

This paper proposes a novel event camera calibration method that models per-pixel contrast threshold biases and variations using both event-only and image-event data. By introducing a new event generation model and employing linear regression for offline and online calibration, the method significantly improves intensity image reconstruction accuracy over state-of-the-art approaches, especially in handling pixel-specific threshold mismatches and noise.

ABSTRACT

Event cameras output asynchronous events to represent intensity changes with a high temporal resolution, even under extreme lighting conditions. Currently, most of the existing works use a single contrast threshold to estimate the intensity change of all pixels. However, complex circuit bias and manufacturing imperfections cause biased pixels and mismatch contrast threshold among pixels, which may lead to undesirable outputs. In this paper, we propose a new event camera model and two calibration approaches which cover event-only cameras and hybrid image-event cameras. When intensity images are simultaneously provided along with events, we also propose an efficient online method to calibrate event cameras that adapts to time-varying event rates. We demonstrate the advantages of our proposed methods compared to the state-of-the-art on several different event camera datasets.

Motivation & Objective

  • Address the problem of inconsistent per-pixel contrast thresholds in event cameras due to circuit-level biases and manufacturing imperfections.
  • Improve the accuracy of event-based image reconstruction by modeling pixel-specific threshold variations instead of assuming a uniform 10% threshold.
  • Develop calibration methods that work for both event-only cameras (e.g., DVS128) and hybrid image-event cameras (e.g., DAVIS, ATIS) using intensity image feedback.
  • Enable real-time, adaptive calibration through an online method that adjusts to time-varying event rates.
  • Demonstrate that accounting for per-pixel bias and threshold variation leads to superior reconstruction quality compared to existing methods.

Proposed method

  • Propose a new event generation model that incorporates per-pixel bias $b^{f p}$ and contrast threshold $c^{f p}$, allowing for pixel-specific response characteristics.
  • Use linear regression to estimate $b^{f p}$ and $c^{f p}$ from event and intensity image data, minimizing the difference between direct integration and reference intensity images.
  • Implement an offline calibration method (OffE, OffEI) that uses full dataset batches to compute optimal parameters for event-only and image-event cameras.
  • Develop an online calibration method (OnEI) that continuously updates parameters in real time using a sliding window of recent events and intensity images.
  • Apply direct integration of events using estimated $b^{f p}$ and $c^{f p}$ to reconstruct intensity images, comparing them to ground-truth frames from the DAVIS camera.
  • Classify pixels into four types based on behavior: stable, noisy, biased, and inactive, to guide parameter estimation and improve robustness.

Experimental results

Research questions

  • RQ1How do circuit-level biases and manufacturing variations affect per-pixel contrast threshold in event cameras?
  • RQ2Can a per-pixel event generation model that accounts for bias and threshold variance improve image reconstruction accuracy?
  • RQ3How does the performance of online calibration compare to offline calibration in dynamic environments with varying event rates?
  • RQ4To what extent can image feedback improve the accuracy of event camera calibration compared to event-only methods?
  • RQ5Can the proposed calibration methods outperform existing state-of-the-art methods in reconstructing intensity images from events?

Key findings

  • The proposed offline calibration method (OffEI) achieves slightly better reconstruction performance than the online method (OnEI), likely due to constant environmental conditions in the datasets.
  • The online calibration method (OnEI) outperforms the method in [5] in all three datasets, demonstrating superior adaptability to time-varying event rates.
  • The event-only calibration method (OffE) performs worse than image-based methods but still outperforms [5] in two of the three datasets, indicating its viability without intensity images.
  • Root Mean Square Error (RMSE) is reduced and Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) are increased across all datasets after calibration, confirming improved image fidelity.
  • The method successfully identifies and mitigates the effects of special pixel types—such as inactive pixels with zero intensity and noisy pixels—by assigning appropriate $b^{f p}$ and $c^{f p}$ values.
  • Contrast threshold values vary significantly from the default 10%, with values ranging up to 15% in some cases, validating the need for per-pixel calibration.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.