[Paper Review] Experimental and Numerical Study of the Transient Response of a Cantilever Beam with a Piezoelectric Disc Sensor
The paper combines experimental measurements and finite element modeling to study the transient response of a cantilever beam with a glued piezoelectric disc sensor, and it identifies damping and electrical parameters using a parameter identification framework.
Online and real-time sensing and monitoring of the health state of complex structures, such as aircraft and critical components of power stations, are essential aspects of research in dynamics. Several types of sensors are used to capture dynamic responses and monitor changes during the operation of critical parts of complex systems. Piezoelectric (PZ) materials belong to a class of electroactive materials that convert mechanical deformation into an electrical response. For example, PZ ceramics or PVDF foils are employed for online sensing of the time history of mechanical deformation. This paper focuses on the dynamical response of a cantilever beam structure equipped with a glued PZ sensor and combines experimental and modelling approaches to achieve accurate and reliable results. The time history of the normal velocity at a point on the beam surface was recorded with a laser vibrometer during transient vibrations of the beam, triggered by the sudden removal of a mass load at the beam's free end. Simultaneously, the output voltage of the PZ sensor was measured with an electronic device. An elastodynamic model of a cantilever beam coupled with a piezoelectric sensor is introduced, along with its discretization using the finite element method. The mathematical model includes additional terms that enforce a floating-potential boundary condition to maintain a constant charge on one of the sensor's electrodes and is presented in an extended form suitable for sensitivity analysis or parameter identification. The model implementation is validated using a numerical example corresponding to the experimental setup. The computed results show good agreement with the experimental data. Furthermore, values of the Rayleigh damping parameters were identified based on the experimental measurements.
Motivation & Objective
- Motivate online sensing and health monitoring of complex structures using piezoelectric sensors.
- Develop a coupled elastodynamic-piezoelectric model for a cantilever beam with an attached PZ sensor.
- Validate the model against experiments and refine parameters via identification.
- Explore the influence of sensor attachment (adhesive layer) on dynamic response.
Proposed method
- Experimentally measure the beam response using a laser vibrometer and a piezoelectric sensor during transient vibration.
- Formulate a piezo-elastodynamic model with coupling between mechanical and electrical fields and enforce floating-potential boundary conditions.
- Discretize the model with finite elements and solve via an extended weak form including Nitsche-type enforcement and an external circuit model.
- Implement the numerical scheme in SfePy and verify against COMSOL results for consistency.
- Provide a parameter identification framework (least-squares) to estimate damping and circuit parameters from measured velocity and voltage data.
Experimental results
Research questions
- RQ1Can the proposed piezo-elastodynamic model reproduce the experimentally observed transient response of the beam.
- RQ2Can the damping (mass- and stiffness-proportional) and external circuit parameters be identified from experimental data in a reliable way.
- RQ3How does the presence of a glue layer between the beam and the piezoelectric disc affect the first eigenfrequency and the electrical response.
- RQ4How well do the numerical results compare with independent simulations (e.g., COMSOL) for modal and transient analyses.
Key findings
- The first eigenfrequency from experiment is 147.59 Hz, while the analytical estimate is 143.62 Hz and the initial FE prediction without glue is 145.44–150.74 Hz depending on model.
- Introducing a thin glue layer between the beam and the piezoelectric disc lowers the principal frequency and brings it closer to the experimental value.
- Model results from SfePy show good agreement with COMSOL for modal analyses when using corresponding meshes.
- A parameter identification procedure can estimate damping coefficients and external circuit parameters from velocity and voltage measurements.
- Model refinements (e.g., modeling the oscilloscope as a resistor and including a glue layer) improve the match between simulated and measured electrical responses.
Read this paper