[Paper Review] Exploiting full Resolution Feature Context for Liver Tumor and Vessel Segmentation via Integrate Framework: Application to Liver Tumor and Vessel 3D Reconstruction under embedded microprocessor
This paper proposes TransFusionNet, a Transformer-based multi-scale feature fusion network that leverages full-resolution feature context to improve liver tumor and vessel segmentation in CT images. By integrating global contextual modeling and efficient feature reconstruction, it achieves state-of-the-art Dice scores of 0.961 for liver tumors and 0.899 for vessels, and successfully deploys the model on an embedded microprocessor for real-time 3D reconstruction with high accuracy.
Liver cancer is one of the most common malignant diseases in the world. Segmentation and labeling of liver tumors and blood vessels in CT images can provide convenience for doctors in liver tumor diagnosis and surgical intervention. In the past decades, many state-of-the-art medical image segmentation algorithms appeared during this period. With the development of embedded devices, embedded deployment for medical segmentation and automatic reconstruction brings prospects for future automated surgical tasks. Yet, most of the existing segmentation methods mostly care about the spatial feature context and have a perception defect in the semantic relevance of medical images, which significantly affects the segmentation accuracy of liver tumors and blood vessels. Deploying large and complex models into embedded devices requires a reasonable trade-off between model accuracy, reasoning speed and model capacity. Given these problems, we introduce a multi-scale feature fusion network called TransFusionNet based on Transformer. This network achieved very competitive performance for liver vessel and liver tumor segmentation tasks, meanwhile it can improve the recognition of morphologic margins of liver tumors by exploiting the global information of CT images. Experiments show that in vessel segmentation task TransFusionNet achieved mean Dice coefficients of 0.899 and in liver tumor segmentation task TransFusionNet achieved mean Dice coefficients of 0.961. Compared with the state-of-the-art framework, our model achieves the best segmentation result. In addition, we deployed the model into an embedded micro-structure and constructed an integrated model for liver tumor vascular segmentation and reconstruction. This proprietary structure will be the exclusive component of the future medical field.
Motivation & Objective
- To address the challenge of low segmentation accuracy in liver tumors and vessels due to limited semantic and spatial context in existing medical image models.
- To develop a lightweight, accurate segmentation model suitable for deployment on resource-constrained embedded microprocessors.
- To enable real-time, automated 3D reconstruction of liver tumors and vascular structures from CT scans for clinical use.
- To improve recognition of fine vessel margins and tumor boundaries, which are critical for surgical planning.
- To bridge the gap between high-accuracy deep learning models and practical deployment in clinical embedded systems.
Proposed method
- Proposes TransFusionNet, a U-Net-like encoder-decoder architecture enhanced with a multi-scale feature fusion decoder to restore high-resolution features.
- Integrates a Vision Transformer (ViT) encoder to capture long-range global context and improve semantic understanding of complex anatomical structures.
- Employs knowledge distillation to compress the full TransFusionNet into a lightweight model suitable for embedded deployment.
- Applies post-processing quantization to further reduce model size and accelerate inference on Jetson TX2.
- Uses a Gaussian filter-based post-processing step to refine segmentation masks: y = G * argmax(o), where o is the predicted label map.
- Deploys the distilled and quantized model on an embedded Jetson TX2 system for real-time 3D reconstruction from CT volumes.
Experimental results
Research questions
- RQ1Can a Transformer-based network effectively exploit full-resolution feature context to improve segmentation of liver tumors and vessels in CT images?
- RQ2How does multi-scale feature fusion enhance the model’s ability to recover fine anatomical details, especially at tumor margins and small vessels?
- RQ3To what extent can a large, accurate segmentation model be compressed and deployed on an embedded microprocessor without significant accuracy loss?
- RQ4Can the embedded deployment enable real-time, high-fidelity 3D reconstruction of liver tumors and vascular structures?
- RQ5How does the proposed method compare to state-of-the-art models in terms of Dice score and reconstruction fidelity?
Key findings
- TransFusionNet achieved a mean Dice coefficient of 0.961 for liver tumor segmentation on the LITS dataset, outperforming state-of-the-art methods.
- For liver vessel segmentation, the model achieved a mean Dice coefficient of 0.899 on the 3DIRCADB dataset, demonstrating superior performance.
- On the authors’ own annotated dataset, the model reached an IOU of 0.927 for tumor segmentation and 0.822 for vessel segmentation, indicating strong generalization.
- The knowledge distillation and quantization pipeline successfully compressed the model for deployment on the Jetson TX2 embedded system.
- The reconstructed 3D models from the embedded system showed high similarity to manual annotations, with only minor noise and minor detail loss.
- The system enables real-time, automated 3D reconstruction of liver tumors and vessels, significantly reducing manual effort compared to traditional annotation.
Read this paper