Skip to main content
QUICK REVIEW

[Paper Review] Extreme-ultraviolet Late Phase in Homologous Solar Flares from a Complex Active Region

Ying Zhong, Yu Dai|arXiv (Cornell University)|May 20, 2021
Solar and Space Plasma DynamicsPhysics and Astronomy68 references8 citations
TL;DR

This study investigates the extreme-ultraviolet late phase (ELP) in six homologous flares from active region NOAA 11283 using SDO data, finding that the ELP's origin shifts from additional heating in the first flare to long-lasting cooling in subsequent flares. A positive correlation between flare ribbon fluence and ELP peak intensity supports cooling as the dominant mechanism in flares F3–F6, with magnetic field evolution and reconnection topology explaining the transition and an exceptionally strong ELP in the confined flare F6.

ABSTRACT

Recent observations in extreme-ultraviolet (EUV) wavelengths reveal a new late phase in some solar flares, which is seen as a second peak in warm coronal emissions ($\sim3$ MK) several tens of minutes to a few hours after the soft X-ray (SXR) peak. The origin of the EUV late phase (ELP) is explained by either a long-lasting cooling process in the long ELP loops, or a delayed energy ejection into the ELP loops well after the main flare heating. Using the observations with the \emph{Solar Dynamics Observatory} (\emph{SDO}), we investigate the production of the ELP in six homologous flares (F1--F6) originating from a complex active region (AR) NOAA 11283, with an emphasis on the emission characteristics of the flares. It is found that the main production mechanism of the ELP changes from additional heating in flare F1 to long-lasting cooling in flares F3--F6, with both mechanisms playing a role in flare F2. The transition is evidenced by an abrupt decrease of the time lag of the ELP peak, and the long-lasting cooling process in the majority of the flares is validated by a positive correlation between the flare ribbon fluence and the ELP peak intensity. We attribute the change in ELP production mechanism to an enhancement of the envelope magnetic field above the AR, which facilitates a more prompt and energetic heating of the ELP loops. In addition, the last and the only confined flare F6 exhibits an extremely large ELP. The different emission pattern revealed in this flare may reflect a different energy partitioning inside the ELP loops, which is due to a different magnetic reconnection process.

Motivation & Objective

  • To understand the physical origin of the extreme-ultraviolet late phase (ELP) in homologous solar flares from a complex active region.
  • To determine whether ELP is driven by delayed heating or prolonged cooling in flare loops.
  • To investigate the role of evolving magnetic fields and reconnection topology in shaping ELP characteristics.
  • To examine the energy partitioning differences in confined vs. eruptive flares, particularly in the ELP.

Proposed method

  • Utilized full-disk EUV irradiance data from SDO/EVE and high-cadence EUV imaging from SDO/AIA to track flare light curves across multiple passbands.
  • Measured flare ribbon fluence by integrating AIA 1600 Å intensity during the impulsive phase, using a 10× background fluctuation threshold.
  • Computed time lags between soft X-ray peak and ELP peak to track temporal evolution of ELP onset.
  • Performed scatter plot analysis between ELP peak intensity and flare ribbon fluence to infer dominant ELP production mechanism.
  • Applied power-law fitting to quantify correlation strength, distinguishing between cooling and additional heating scenarios.
  • Analyzed magnetic configuration evolution and reconnection topology using HMI magnetograms and prior force-free field extrapolations.

Experimental results

Research questions

  • RQ1What is the dominant physical mechanism (additional heating vs. long-lasting cooling) responsible for the ELP in homologous flares from the same active region?
  • RQ2How does the time lag between the SXR peak and ELP peak evolve across successive flares, and what does it indicate about ELP formation?
  • RQ3What role does the overlying magnetic field strength and configuration play in transitioning the ELP mechanism from heating to cooling?
  • RQ4Why does the confined flare F6 exhibit an exceptionally strong ELP compared to other flares in the series?
  • RQ5How does the energy partitioning in ELP loops differ in confined versus eruptive flares, particularly in terms of thermal vs. non-thermal energy deposition?

Key findings

  • The ELP production mechanism transitions from additional heating in flare F1 to long-lasting cooling in flares F3–F6, with both mechanisms contributing in flare F2.
  • The time lag between the SXR peak and ELP peak decreases abruptly after flare F1, indicating a shift from delayed heating to earlier, more efficient loop heating.
  • A strong positive correlation (r = 0.946) between remote flare ribbon fluence and ELP peak intensity supports long-lasting cooling as the dominant mechanism in flares F3–F6.
  • Flare F6, the only confined flare, exhibits an extremely large ELP peak, suggesting different energy partitioning due to slip-running reconnection in the quasi-separatrix layer.
  • The enhanced overlying magnetic field after flare F1 likely caused more prompt and energetic heating of ELP loops, facilitating the cooling-dominated ELP in later flares.
  • The NS-oriented flux rope in flares F3 and F6 correlates with the strongest ELP peaks, indicating that orientation affects interaction efficiency with overlying field lines.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.