Skip to main content
QUICK REVIEW

[Paper Review] Fast and accurate detection of Covid-19-related pneumonia from chest X-ray images with novel deep learning model

M. M. Ramadhan, A. Faza|arXiv (Cornell University)|May 10, 2020
COVID-19 diagnosis using AIMedicine8 citations
TL;DR

This paper proposes CovIDNet, a novel deep learning model for fast and accurate detection of COVID-19-related pneumonia from chest X-ray (CXR) images. Trained on open-source CXR datasets from GitHub and Kaggle, the model achieves 98.44% accuracy, 100% precision for COVID-19, and 96.97% specificity, demonstrating high performance in classifying COVID-19 from other pulmonary pathologies.

ABSTRACT

Background: Novel coronavirus disease has spread rapidly worldwide. As recent radiological literatures on Covid-19 related pneumonia is primarily focused on CT findings, the American College of Radiology (ACR) recommends using portable chest X-radiograph (CXR). A tool to assist for detection and monitoring of Covid-19 cases from CXR is highly required. Purpose: To develop a fully automatic framework to detect Covid-19 related pneumonia using CXR images and evaluate its performance. Materials and Methods: In this study, a novel deep learning model, named CovIDNet (Covid-19 Indonesia Neural-Network), was developed to extract visual features from chest x-ray images for the detection of Covid-19 related pneumonia. The model was trained and validated by chest x-rays datasets collected from several open source provided by GitHub and Kaggle. Results and Discussion: In the validation stage using open-source data, the accuracy to recognize Covid-19 and others classes reaches 98.44%, that is, 100% Covid-19 precision and 97% others precision. Discussion: The use of the model to classify Covid-19 and other pathologies might slightly decrease the accuracy. Although SoftMax was used to handle classification bias, this indicates the benefit of additional training upon the introduction of new set of data. Conclusion: The model has been tested and get 98.4% accuracy for open source datasets, the sensitivity and specificity are 100% and 96.97%, respectively.

Motivation & Objective

  • To develop a fully automatic deep learning framework for detecting COVID-19-related pneumonia from portable chest X-ray (CXR) images.
  • To address the clinical need for rapid, accessible diagnostic tools during the pandemic, especially given the limitations of CT-based diagnosis.
  • To improve diagnostic accuracy and speed for frontline healthcare providers using widely available CXR imaging.
  • To evaluate the model’s performance on open-source CXR datasets with diverse pathological conditions.

Proposed method

  • A novel deep learning model named CovIDNet (Covid-19 Indonesia Neural-Network) was developed to extract visual features from CXR images.
  • The model was trained and validated using chest X-ray datasets collected from open-source repositories on GitHub and Kaggle.
  • Feature extraction and classification were performed using a convolutional neural network architecture optimized for CXR image analysis.
  • SoftMax was employed during training to mitigate class imbalance and improve classification fairness.
  • The model was evaluated using standard metrics including accuracy, precision, sensitivity, and specificity.
  • Performance was tested on a validation set comprising images labeled as COVID-19 or other pulmonary pathologies.

Experimental results

Research questions

  • RQ1Can a deep learning model achieve high accuracy in distinguishing COVID-19-related pneumonia from other lung pathologies using only chest X-ray images?
  • RQ2How does the model perform in terms of sensitivity and specificity when detecting COVID-19 in a diverse CXR dataset?
  • RQ3To what extent does class imbalance in the training data affect the model’s classification performance?
  • RQ4Can the model generalize across different data sources and imaging variations present in open-source CXR collections?
  • RQ5How does the use of SoftMax loss help in reducing bias during classification of rare conditions like COVID-19?

Key findings

  • The model achieved 98.44% accuracy in classifying COVID-19 and non-COVID-19 cases on open-source datasets.
  • Sensitivity for detecting COVID-19 was 100%, indicating no false negatives in the validation set.
  • Specificity was 96.97%, meaning the model correctly identified 96.97% of non-COVID-19 cases.
  • Precision for the COVID-19 class reached 100%, indicating all positive predictions were correct.
  • The model showed high precision (97%) for the 'other' pathology class, suggesting strong generalization across non-COVID conditions.
  • The study indicates that additional fine-tuning may be necessary when introducing new data to maintain high performance.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.