[Paper Review] Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap
This study measures the neutron lifetime using the fill and dump technique in an asymmetric magneto-gravitational trap at Los Alamos, where ultracold neutrons are stored and then unloaded into an external detector for counting. The result, τₙ = 877.1(2.6)stat(0.8)syst, is consistent with prior in situ measurements, providing a critical cross-check for systematic uncertainties in neutron lifetime experiments.
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.
Motivation & Objective
- To test the consistency of neutron lifetime measurements using a different counting method—fill and dump—compared to in situ detection.
- To investigate potential systematic errors in previous in situ measurements that might explain the 4.4σ discrepancy between beam and trap-based lifetime determinations.
- To validate the robustness of the neutron lifetime measurement by applying an alternative counting technique in the same experimental apparatus.
- To contribute to resolving the long-standing neutron lifetime puzzle by providing an independent measurement with distinct systematic error profiles.
Proposed method
- Ultracold neutrons (UCN) are produced via spallation of 800 MeV protons on solid deuterium at the LANSCE facility.
- UCN are pre-polarized in a 6 T superconducting solenoid and adiabatically spin-flipped to low-field-seeking states for trapping.
- Neutrons are loaded into an asymmetric magneto-gravitational trap formed by Halbach arrays, with a 48 neV trapping potential.
- After storage, neutrons are unloaded through a 'trap door' and counted externally using a dedicated detector, enabling the fill and dump technique.
- Counting is normalized using an active cleaner and monitor in the buffer volume to account for beam intensity fluctuations.
- Systematic uncertainties are evaluated by comparing the fill and dump method with prior in situ detection in the same apparatus.
Experimental results
Research questions
- RQ1Does the fill and dump counting method yield a neutron lifetime consistent with in situ detection in the same trap?
- RQ2Can the fill and dump method reveal systematic effects not present in in situ measurements that might explain the 4.4σ discrepancy between beam and trap-based measurements?
- RQ3What is the impact of phase space evolution coupling on counting time in external versus in situ detection?
- RQ4How do the systematic uncertainties in the fill and dump method compare to those in the in situ method?
- RQ5Does the new method support or challenge the hypothesis that charge exchange on residual gas could explain the discrepancy in neutron lifetime measurements?
Key findings
- The neutron lifetime measured via the fill and dump method is τₙ = 877.1(2.6)stat(0.8)syst s, in statistical agreement with prior in situ measurements.
- The external counting method has a longer time constant (26.8(8) s) compared to in situ detection (7.1(2) s), increasing sensitivity to phase space evolution effects.
- No new systematic errors were identified that could explain the 4.4σ discrepancy between beam and trap-based lifetime measurements.
- The consistency between fill and dump and in situ results supports the reliability of the in situ measurement method.
- The results strengthen confidence in the neutron lifetime value but do not resolve the persistent discrepancy with beam-based measurements.
- The study confirms that the fill and dump technique, despite its disadvantages, provides a valuable cross-check for systematic uncertainties in neutron lifetime experiments.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.