Skip to main content
QUICK REVIEW

[Paper Review] Fluorescence emission induced by extensive air showers in dependence on atmospheric conditions

B. Keilhauer, M. Unger|ArXiv.org|Jun 30, 2009
Astrophysics and Cosmic PhenomenaPhysics and Astronomy1 references4 citations
TL;DR

This paper presents a refined fluorescence yield model (K08) for extensive air showers, incorporating temperature- and humidity-dependent collisional quenching effects in nitrogen fluorescence. Using actual atmospheric soundings instead of monthly averages, it shows that ignoring these dependencies can cause energy reconstruction errors up to ±7% and $X_{\mathrm{max}}$ biases up to ±5\,g\,cm$^{-2}$, with the largest systematic effects occurring for showers developing high or deep in the atmosphere.

ABSTRACT

Charged particles of extensive air showers (EAS), mainly electrons and positrons, initiate the emission of fluorescence light in the Earth's atmosphere. This light provides a calorimetric measurement of the energy of cosmic rays. For reconstructing the primary energy from an observed light track of an EAS, the fluorescence yield in air has to be known in dependence on atmospheric conditions, like air temperature, pressure, and humidity. Several experiments on fluorescence emission have published various sets of data covering different parts of the dependence of the fluorescence yield on atmospheric conditions. Using a compilation of published measurements, a calculation of the fluorescence yield in dependence on altitude is presented. The fluorescence calculation is applied to simulated air showers and different atmospheric profiles to estimate the influence of the atmospheric conditions on the reconstructed shower parameters.

Motivation & Objective

  • To improve the accuracy of cosmic ray energy reconstruction in fluorescence detectors by accounting for atmospheric dependencies in nitrogen fluorescence yield.
  • To quantify the impact of temperature and water vapor pressure on fluorescence emission using measured collisional cross sections.
  • To assess how atmospheric profile variations—especially from real soundings versus monthly averages—affect reconstructed shower parameters.
  • To evaluate the systematic uncertainties introduced by different fluorescence yield models and their dependence on atmospheric conditions.

Proposed method

  • The K08 fluorescence model incorporates temperature- and pressure-dependent collisional quenching using updated cross sections for N₂–N₂, N₂–O₂, and N₂–H₂O collisions.
  • The model uses the fluorescence yield equation $ Y_{\lambda} = \Phi^{0}_{\lambda} \cdot \lambda / hc \cdot (1 + P/P'_{v})^{-1} $, where $ P'_{v} $ depends on collisional cross sections and temperature.
  • Simulated air showers were reconstructed using the K08 model with real atmospheric profiles from local radio soundings (109 profiles), compared to standard monthly models.
  • The study compares reconstruction results using the K08 model with and without $\sigma_T$ (temperature-dependent) and $\sigma_e$ (vapor quenching) effects to isolate their contributions.
  • Systematic uncertainties were evaluated by comparing results from two independent measurements of collisional cross sections ($\sigma_e^W$ and $\sigma_e^M$) and varying $\alpha$-coefficients for temperature dependence.
  • The analysis used the Pierre Auger Observatory's $\overline{\textrm{Off}}$\underline{\textrm{line}} simulation and reconstruction framework to ensure consistency across models.

Experimental results

Research questions

  • RQ1How do temperature and water vapor pressure affect the fluorescence yield in nitrogen-dominated air showers?
  • RQ2What is the impact of ignoring temperature- and humidity-dependent quenching on reconstructed primary energy and $X_{\mathrm{max}}$?
  • RQ3How do actual atmospheric soundings compare to standard monthly models in terms of shower reconstruction accuracy?
  • RQ4What are the systematic uncertainties introduced by different fluorescence yield models and cross-section measurements?
  • RQ5How do proton- and iron-induced showers respond differently to atmospheric variations in the fluorescence reconstruction?

Key findings

  • Ignoring temperature-dependent collisional quenching ($\sigma_T$) leads to energy reconstruction errors of up to -7% for showers with $X_{\mathrm{max}}$ high in the atmosphere.
  • Neglecting water vapor quenching ($\sigma_e$) causes energy underestimation of up to 7% for showers with $X_{\mathrm{max}}$ near the ground.
  • The position of shower maximum ($X_{\mathrm{max}}$) is biased by up to -5 g cm⁻² for deep showers and +5 g cm⁻² for high showers, with the largest shifts occurring around 3 km and 9 km a.s.l.
  • The $\sigma_e$ and $\sigma_T$ dependencies partially cancel each other in $X_{\mathrm{max}}$ reconstruction, reducing the net effect on $X_{\mathrm{max}}$.
  • Using actual atmospheric soundings instead of monthly models introduces less than 1% difference in reconstructed energy and below 2 g cm⁻² in $X_{\mathrm{max}}$.
  • The RMS uncertainty in reconstructed energy due to atmospheric profile variation is in the range [1.5, 3.0]%, and for $X_{\mathrm{max}}$ it is [7.2, 8.4] g cm⁻².

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.