Skip to main content
QUICK REVIEW

[Paper Review] Foveated Thermal Computational Imaging in the Wild Using All-Silicon Meta-Optics

Vishwanath Saragadam, Zheyi Han|arXiv (Cornell University)|Dec 13, 2022
Photonic and Optical DevicesEngineering5 citations
TL;DR

This paper presents the first real-time, all-silicon meta-optical system for foveated thermal imaging in the long-wavelength infrared (LWIR) band. By leveraging polarization-sensitive metalenses and a rotating polarizer to multiplex high-resolution foveal and low-resolution perifoveal images, followed by computational reconstruction via deep image prior or fast least squares, the system achieves 12 fps foveated video capture in real-world conditions with a 1:6 foveal expansion.

ABSTRACT

Foveated imaging provides a better tradeoff between situational awareness (field of view) and resolution and is critical in long-wavelength infrared regimes because of the size, weight, power, and cost of thermal sensors. We demonstrate computational foveated imaging by exploiting the ability of a meta-optical frontend to discriminate between different polarization states and a computational backend to reconstruct the captured image/video. The frontend is a three-element optic: the first element which we call the "foveal" element is a metalens that focuses s-polarized light at a distance of $f_1$ without affecting the p-polarized light; the second element which we call the "perifoveal" element is another metalens that focuses p-polarized light at a distance of $f_2$ without affecting the s-polarized light. The third element is a freely rotating polarizer that dynamically changes the mixing ratios between the two polarization states. Both the foveal element (focal length = 150mm; diameter = 75mm), and the perifoveal element (focal length = 25mm; diameter = 25mm) were fabricated as polarization-sensitive, all-silicon, meta surfaces resulting in a large-aperture, 1:6 foveal expansion, thermal imaging capability. A computational backend then utilizes a deep image prior to separate the resultant multiplexed image or video into a foveated image consisting of a high-resolution center and a lower-resolution large field of view context. We build a first-of-its-kind prototype system and demonstrate 12 frames per second real-time, thermal, foveated image, and video capture in the wild.

Motivation & Objective

  • Address the challenge of simultaneously achieving high-resolution target detection and wide-field situational awareness in thermal imaging systems.
  • Overcome limitations of traditional foveated sensors and dynamic optics in the LWIR band due to large pixel sizes and material constraints.
  • Enable real-time, computational foveated imaging in the wild using all-silicon meta-optics with polarization multiplexing.
  • Demonstrate a prototype system capable of 12 fps foveated thermal video capture with high-quality reconstruction.

Proposed method

  • Design a three-element meta-optical frontend: a foveal metalens focusing s-polarized light at 150 mm, a perifoveal metalens focusing p-polarized light at 25 mm, and a freely rotating polarizer to control mixing ratios.
  • Fabricate both metalenses as polarization-sensitive, all-silicon meta-surfaces to enable large-aperture, low-loss, broadband LWIR operation.
  • Use a rotating polarizer to dynamically modulate the intensity ratio between foveal and perifoveal images, creating a multiplexed measurement on a single thermal sensor.
  • Apply a computational backend using deep image prior to unmix and reconstruct high-resolution foveal and low-resolution perifoveal images from the multiplexed data.
  • Enable real-time reconstruction via a fast least squares solver when mixing ratios are known a priori, achieving up to 40 fps with bilateral filtering to reduce noise.
  • Implement a two-stage image registration and calibration pipeline to estimate rigid transformations (scale and translation) between foveal and perifoveal components for accurate reconstruction.

Experimental results

Research questions

  • RQ1Can polarization-multiplexed meta-optics enable foveated thermal imaging in the LWIR band where traditional optics and sensors face fundamental limitations?
  • RQ2How can computational imaging techniques be leveraged to reconstruct high-quality foveated thermal images from a single multiplexed measurement?
  • RQ3What is the optimal number of frames required for high-quality reconstruction without motion blur or poor separation?
  • RQ4Can real-time foveated thermal video be achieved with a computationally efficient method when mixing ratios are known a priori?
  • RQ5How can system calibration be performed robustly when mechanical alignment varies across captures?

Key findings

  • The prototype system successfully captures foveated thermal video at 12 frames per second in real-world conditions, demonstrating the first real-time implementation of computational foveated imaging in the LWIR band.
  • Using 12–16 frames per capture, the system achieves optimal reconstruction quality, balancing information content and motion blur, with poor separation at fewer frames and increased blur at higher frame counts.
  • Real-time reconstruction at up to 40 fps is achievable using a known mixing ratio and a fast least squares solver, though results are noisier than those from deep image prior-based reconstruction.
  • Deep image prior-based reconstruction produces higher quality results but requires up to 50 seconds per frame, making it unsuitable for real-time use.
  • The two-stage calibration process—initial translation estimation with fixed 1:6 scale followed by intensity-based refinement—enables accurate registration of foveal and perifoveal components across variable alignments.
  • The system achieves a 1:6 foveal expansion (150 mm vs. 25 mm focal length), enabling high-resolution central imaging with a wide field of view context, validated through both simulation and real-world experiments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.