[Paper Review] Frequency domain method of the search for the deuteron electric dipole moment in a storage ring with imperfections
This paper proposes a frequency-domain method to measure the deuteron electric dipole moment (EDM) in a storage ring with magnetic and electric field imperfections. By measuring the total spin precession frequency in the vertical plane and using counter-clockwise/clockwise beam operation to cancel systematic errors, the method achieves a projected sensitivity of ~10⁻²⁹ e·cm, significantly reducing false signals from field misalignments and enabling high-precision EDM searches despite ring imperfections.
The method is based on four fundamental features. The total spin precession frequency in the vertical plane due to the electric and magnetic dipole moments in an imperfect ring in a vertical plane is measured. The position of the ring elements is unchanged from clockwise to counter-clockwise operation. The calibration of the effective Lorentz factor using the polarization precession frequency measurement in the horizontal plane is carried out alternately in each CW and CCW operation. And the approximate relationship between the frequencies of the polarization precession in different planes is set to exclude them from mixing to the vertical frequency of the expected EDM signal at a sensitivity level approaching $10^{-29}$ $e\cdot cm$.
Motivation & Objective
- To address the challenge of systematic errors from field imperfections in storage ring experiments searching for the deuteron electric dipole moment (EDM).
- To enable high-sensitivity EDM measurements in rings with unavoidable magnetic and electric field misalignments.
- To develop a method that maintains the frozen spin condition while suppressing fake EDM signals from radial and vertical field components.
- To achieve a sensitivity approaching 10⁻²⁹ e·cm despite experimental imperfections.
- To provide a robust alternative to purely electrostatic rings, applicable to electromagnetic storage rings with both electric and magnetic fields.
Proposed method
- Measure the total spin precession frequency in the vertical plane, combining contributions from the EDM, magnetic dipole moment (MDM), and field imperfections.
- Use simultaneous clockwise (CW) and counter-clockwise (CCW) beam operation to cancel systematic errors: signals from MDM and field imperfections reverse sign, while the EDM signal remains additive.
- Calibrate the effective Lorentz factor via polarization precession frequency measurements in the horizontal plane during alternating CW and CCW runs.
- Apply the condition Ω ≈ (Ω_edm + Ω_Br) · [1 + (Ω_Bv,Er² + Ω_Bz²)/(2(Ω_edm + Ω_Br)²)] to isolate the EDM signal from background contributions.
- Utilize a longitudinal solenoid to stabilize the vertical field component, ensuring Ω_Bv,Er and Ω_Bz remain small enough to not distort the EDM frequency measurement.
- Leverage the fact that the spin precession frequency is insensitive to amplitude and phase, focusing only on frequency to extract the EDM signal.
Experimental results
Research questions
- RQ1How can systematic errors from magnetic and electric field imperfections in a storage ring be suppressed to enable high-sensitivity EDM measurements?
- RQ2Can the frequency-domain measurement of total spin precession in the vertical plane replace direct measurement of the vertical spin component to improve EDM sensitivity?
- RQ3To what extent can the CW/CCW beam operation technique be adapted to electromagnetic storage rings with both electric and magnetic fields?
- RQ4What are the required tolerances on radial and vertical field components (Ω_Br, Ω_Bv,Er, Ω_Bz) to ensure they do not obscure the EDM signal at the 10⁻²⁹ e·cm level?
- RQ5How can the frozen spin condition be maintained in a deuteron ring with negative anomalous magnetic moment (G = -0.143) despite field imperfections?
Key findings
- The method achieves a projected sensitivity of ~10⁻²⁹ e·cm for the deuteron electric dipole moment, approaching the theoretical limit of current storage ring experiments.
- Systematic errors from radial and vertical field components (Ω_Bv,Er and Ω_Bz) can be suppressed below the EDM signal level if their contributions satisfy the condition (Ω_Bv,Er² + Ω_Bz²)/(2Ω_Br) < Ω_edm.
- With Ω_Br ≈ 50 rad/sec and Ω_edm ≈ 10⁻⁸ rad/sec, the maximum allowable spin rotation from imperfections over a 1000-second coherence time is ~1 radian, which is technically feasible.
- The use of a longitudinal solenoid allows stabilization of the vertical field component without requiring precise knowledge of its absolute value, as only the relative frequency shift matters.
- The method is robust against misalignments of quadrupoles and deflectors, provided the optics are symmetric for CW and CCW operation.
- The approach extends the applicability of the frozen spin method to electromagnetic storage rings for deuterons, overcoming limitations of purely electrostatic rings.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.