Skip to main content
QUICK REVIEW

[Paper Review] Frequency Ratio of ${}^{199}$Hg and ${}^{87}$Sr Optical Lattice Clocks beyond the SI Limit

K. Yamanaka, Noriaki Ohmae|arXiv (Cornell University)|Mar 27, 2015
Advanced Frequency and Time StandardsPhysics and Astronomy11 citations
TL;DR

This paper reports a frequency ratio measurement between a 199Hg and an 87Sr optical lattice clock with a fractional uncertainty of 8.4×10⁻¹⁷, surpassing the SI second's uncertainty limit. By precisely characterizing lattice light shifts—including multipolar polarizabilities—the Hg clock achieves a total systematic uncertainty of 7.2×10⁻¹⁷, enabling high-precision tests of fundamental physics, including the constancy of the fine-structure constant.

ABSTRACT

We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 imes 10^{-17}$ for the Hg clock. The frequency ratio is measured to be $ν_{ m Hg}/ν_{ m Sr}=2.629\, 314\, 209\, 898\, 909\, 60(22)$ with a fractional uncertainty of $8.4 imes 10^{-17}$, which is smaller than the uncertainty of the realization of the SI second, i.e., the SI limit.

Motivation & Objective

  • To achieve a frequency ratio between 199Hg and 87Sr optical lattice clocks with uncertainty below the SI second's limit.
  • To reduce systematic uncertainties in the 199Hg optical lattice clock to below 10⁻¹⁶, particularly lattice light shifts.
  • To enable high-precision tests of the constancy of the fine-structure constant α using Hg as a sensitive probe.
  • To validate the use of Sr clocks as an α-insensitive anchor for long-term frequency comparison.

Proposed method

  • A 199Hg optical lattice clock is operated at the magic wavelength of 363 nm, with atoms laser-cooled via the 1S₀–3P₁ transition at 254 nm.
  • Atoms are loaded into a one-dimensional optical lattice with a trap depth of 65 E_R, followed by vibrational state cooling to reduce heating effects.
  • The 1S₀–3P₀ clock transition at 266 nm is probed using a laser referenced to the Sr clock laser via an optical frequency comb.
  • Lattice light shift is evaluated using multipolar polarizabilities, including higher-order contributions, to correct for systematic shifts.
  • The frequency ratio ν_Hg/ν_Sr is measured by synchronously comparing the two clocks over multiple cycles with a 1.5 s cycle time.
  • Systematic uncertainties are evaluated through temperature, magnetic field, gravity, and Dick-effect-limited noise analysis.

Experimental results

Research questions

  • RQ1Can the frequency ratio between 199Hg and 87Sr optical lattice clocks be measured with uncertainty below the SI second's uncertainty limit?
  • RQ2How do multipolar polarizabilities affect the lattice light shift in Hg clocks, and can they be accurately modeled to reduce systematic uncertainty?
  • RQ3What is the absolute frequency of the 199Hg 1S₀–3P₀ transition when referenced to the CIPM-recommended 87Sr frequency?
  • RQ4Can the Hg clock's systematic uncertainty be reduced to 7.2×10⁻¹⁷ through comprehensive correction of lattice-induced shifts?
  • RQ5What is the potential of this ratio measurement for testing the time-variability of the fine-structure constant α?

Key findings

  • The frequency ratio ν_Hg/ν_Sr is measured as 2.629 314 209 898 909 60(22) with a fractional uncertainty of 8.4×10⁻¹⁷, surpassing the SI second's uncertainty limit.
  • The 199Hg optical lattice clock achieves a total systematic uncertainty of 7.2×10⁻¹⁷ through detailed modeling of multipolar polarizabilities and lattice light shifts.
  • The absolute frequency of the 199Hg clock transition is determined as 1 128 575 290 808 155.4(1.1) Hz, based on the CIPM-recommended 87Sr frequency.
  • The measurement is consistent with the LNE-SYRTE group's result within 1σ uncertainty, validating cross-laboratory reproducibility.
  • The instability of the ratio measurement reaches 3×10⁻¹⁵/√τ, limited by the Dick effect, with quantum projection noise contributing only 4×10⁻¹⁶/√τ.
  • The result enables future tests of the fine-structure constant's constancy with a projected sensitivity of Δα/α ≈ 0.8Δν/ν_Hg, reaching 10⁻¹⁷-level sensitivity over a year.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.