[Paper Review] Frequency Stability Measurement of Cryogenic Sapphire Oscillators with a Multichannel Tracking DDS and the Two-Sample Covariance

Claudio Calosso, F. Vernotte|arXiv (Cornell University)|Aug 29, 2018
Advanced Frequency and Time StandardsPhysics and Astronomy41 references14 citations
TL;DR

This paper presents a novel method for measuring the frequency stability of cryogenic sapphire oscillators (CSOs) at 100 MHz using a 6-channel tracking direct digital synthesizer (TDDS) and the two-sample covariance technique. By leveraging dual-channel correlation per CSO, the method suppresses instrument background noise to below 10⁻¹⁸ at 10⁴ s integration time, enabling direct Allan deviation measurements of CSOs with stability down to 2×10⁻¹⁶ at 1 s, surpassing traditional beat-note methods and H masers by two orders of magnitude.

ABSTRACT

This article shows the first measurement of three 100 MHz signals exhibiting fluctuations from 2E-16 to parts in 1E-15 for integration time tau between 1 s and 1 day. Such stable signals are provided by three Cryogenic Sapphire Oscillators (CSOs) operating at about 10 GHz, also delivering the 100 MHz output via a dedicated synthesizer. The measurement is made possible by a 6-channel Tracking DDS (TDDS) and the two-sample covariance tool, used to estimate the Allan variance. The use of two TDDS channels per CSO enables high rejection of the instrument background noise. The covariance outperforms the Three-Cornered Hat (TCH) method in that the background converges to zero "out of the box," with no need of the hypothesis that the instrument channels are equally noisy, nor of more sophisticated techniques to estimate the background noise of each channel. Thanks to correlation and averaging, the instrument background (AVAR) rolls off with a slope 1/sqrt(m), the number of measurements, down to 1E-18 tau = 1E4 s. For consistency check, we compare the results to the traditional TCH method beating the 10 GHz outputs down to the MHz region. Given the flexibility of the TDDS, our methods find immediate application to the measurement of the 250 MHz output of the FS combs.

Motivation & Objective

  • To enable direct, high-precision frequency stability measurements of cryogenic sapphire oscillators (CSOs) at 100 MHz, bypassing traditional beat-note techniques.
  • To overcome the limitation of instrument background noise in commercial measurement systems, which otherwise masks the intrinsic stability of CSOs.
  • To demonstrate that the two-sample covariance method can suppress background noise to near-zero levels without requiring assumptions about channel noise uniformity or complex background estimation.
  • To validate the method against the established three-cornered hat (TCH) technique using beat notes at lower frequencies.
  • To establish a scalable, flexible framework for measuring ultra-stable microwave signals in strategic metrology and space applications.

Proposed method

  • A 6-channel tracking direct digital synthesizer (TDDS) synchronously locks to the 100 MHz outputs of three CSOs, extracting phase information via phase-locked loop (PLL) control of digital frequency synthesis.
  • The two-sample covariance method is applied to estimate Allan variance, with two TDDS channels assigned per CSO to enable noise cancellation through correlation and averaging.
  • Instrument background noise (AVAR) rolls off as 1/√m, where m is the number of measurements, enabling suppression to 10⁻¹⁸ at τ = 10⁴ s.
  • The method avoids the need for background noise estimation by leveraging the theoretical convergence of covariance to zero when channels are uncorrelated with the signal.
  • The TDDS operates at intermediate frequencies (5–400 MHz), avoiding high-speed ADCs and reducing phase noise compared to sampling-based methods.
  • Drift is removed from data using linear fitting, and statistical consistency is verified by comparing results with the traditional TCH method on 10 GHz beat notes.

Experimental results

Research questions

  • RQ1Can the two-sample covariance method achieve background noise suppression to below 10⁻¹⁸ without prior knowledge of channel noise characteristics?
  • RQ2Does direct 100 MHz measurement of CSOs yield lower Allan deviation than traditional beat-note methods using lower intermediate frequencies?
  • RQ3To what extent does the TDDS-based system outperform conventional sampling-based phase measurement in terms of phase noise and dynamic range?
  • RQ4How does the stability of CSOs at 100 MHz compare to that of H masers and other atomic standards over integration times from 1 s to 1 day?
  • RQ5What is the impact of thermal and electronic instabilities (e.g., power control failure) on long-term stability measurements?

Key findings

  • The CSOs exhibit a short-term Allan deviation of 2×10⁻¹⁶ at 1 s integration time, surpassing H masers by two orders of magnitude.
  • The two-sample covariance method suppresses instrument background noise to below 10⁻¹⁸ at τ = 10⁴ s, with a theoretical roll-off of 1/√m.
  • The measured Allan deviation of the 100 MHz output of CSOs reaches 1.5×10⁻¹⁵ at τ = 1 s, corresponding to a time stability of 1.5 fs or a length stability of 400 nm on a coaxial cable.
  • The covariance method shows excellent agreement with the TCH method for τ > 100 s, confirming consistency and reliability of the results.
  • Oscillator B exhibits a drift of 4.5×10⁻¹⁸ /s (3.9×10⁻¹³ /day), traced to a failed power control system, which also causes a bump in instability at τ = 20 s in the covariance plot.
  • Theoretical residuals fit the observed data well, with a predicted σ = 8×10⁻¹⁶ / τ³/⁴, indicating that the measurement is limited by the time series duration and not by hardware or methodological noise.