Skip to main content
QUICK REVIEW

[Paper Review] From prosumer to flexumer: Case study on the value of flexibility in decarbonizing the multi-energy system of a manufacturing company

Markus Fleschutz, Markus Bohlayer|arXiv (Cornell University)|Jan 19, 2023
Electric Vehicles and InfrastructureEngineering3 citations
TL;DR

This study proposes a mixed-integer linear programming (MILP) model to optimize the design and operation of a multi-energy system (MES) in a beverage manufacturing company, quantifying the value of flexibility through price- and carbon emission factor-based demand response. Results show that leveraging flexibility reduces decarbonization costs by 19–80%, lowers total annual costs, carbon emissions, and fossil fuel dependence, with net-zero emissions only achievable through integrated storage and flexible technologies.

ABSTRACT

Digitalization and sector coupling enable companies to turn into flexumers. By using the flexibility of their multi-energy system (MES), they reduce costs and carbon emissions while stabilizing the electricity system. However, to identify the necessary investments in energy conversion and storage technologies to leverage demand response (DR) potentials, companies need to assess the value of flexibility. Therefore, this study quantifies the flexibility value of a production company's MES by optimizing the synthesis, design, and operation of a decarbonizing MES considering self-consumption optimization, peak shaving, and integrated DR based on hourly prices and carbon emission factors (CEFs). The detailed case study of a beverage company in northern Germany considers vehicle-to-X of powered industrial trucks, power-to-heat on multiple temperatures, wind turbines, photovoltaic systems, and energy storage systems (thermal energy, electricity, and hydrogen). We propose and apply novel data-driven metrics to evaluate the intensity of price-based and CEF-based DR. The results reveal that flexibility usage reduces decarbonization costs (by 19-80% depending on electricity and carbon removal prices), total annual costs, operating carbon emissions, energy-weighted average prices and CEFs, and fossil energy dependency. The results also suggest that a net-zero operational carbon emission MES requires flexibility, which, in an economic case, is provided by a combination of different flexible technologies and storage systems that complement each other. While the value of flexibility depends on various market and consumer-specific factors such as electricity or carbon removal prices, this study highlights the importance of demand flexibility for the decarbonization of MESs.

Motivation & Objective

  • To quantify the economic and environmental value of energy flexibility in decarbonizing a commercial and industrial (C&I) company’s multi-energy system (MES).
  • To evaluate the role of demand response (DR) based on hourly electricity prices and carbon emission factors (CEFs) in reducing operational costs and emissions.
  • To assess the impact of integrating distributed energy resources (DERs), including wind, PV, vehicle-to-X (V2X), power-to-heat, and energy storage systems.
  • To develop and apply novel data-driven metrics for evaluating the intensity of price-based and emission-based DR in industrial settings.
  • To determine the optimal mix of technologies and storage systems required to achieve net-zero operational carbon emissions in a cost-effective manner.

Proposed method

  • Developed a mixed-integer linear programming (MILP) model to simultaneously optimize synthesis, design, and operation of the MES over a full year.
  • Incorporated hourly electricity prices and time-varying carbon emission factors (CEFs) as key signals for price- and emission-based demand response (DR).
  • Modeled multiple energy conversion and storage technologies: photovoltaics (PV), wind turbines, battery energy storage (BES), thermal energy storage (TES), hydrogen storage (H2S), power-to-heat (P2H), and vehicle-to-X (V2X) for electric forklifts.
  • Applied novel normalized flexibility metrics (π-rate, ε-rate, EWAP, EWACEF) to evaluate DR intensity and signal dominance (price vs. CEF) across scenarios.
  • Conducted comparative scenario analysis: base case (no flexibility), strict net-zero CE case, and high-price shock scenario (c_scaled), assessing investment and operational decisions.
  • Used total annualized cost (TAC), carbon emissions (CE), and energy-weighted average metrics (EWAP, EWACEF) as key performance indicators (KPIs).

Experimental results

Research questions

  • RQ1What is the economic and environmental value of energy flexibility in decarbonizing a C&I company’s multi-energy system?
  • RQ2How do price-based and carbon emission factor-based demand response compare in terms of intensity and effectiveness?
  • RQ3What is the optimal combination of distributed energy resources and storage systems required to achieve net-zero operational carbon emissions cost-effectively?
  • RQ4How do high and volatile electricity prices influence investment in renewable energy and energy storage systems?
  • RQ5To what extent does demand flexibility reduce total annual costs, carbon emissions, and fossil fuel dependency in industrial MES?

Key findings

  • The use of energy flexibility reduces decarbonization costs by 19–80% across different electricity and carbon removal price scenarios.
  • Net-zero operational carbon emissions in the MES are only achievable through the integration of flexible technologies and storage systems, with no feasible path without such flexibility.
  • Energy-weighted average price (EWAP) and energy-weighted average carbon emission factor (EWACEF) fell below time-weighted averages (TWAP and TWACEF) when flexibility was used, indicating lower-cost and greener electricity procurement.
  • The novel flexibility metrics π-rate and ε-rate effectively normalized and visualized DR intensity, enabling comparison across market and policy contexts.
  • High electricity price volatility (as in the 2022 shock scenario) significantly increased the activation of existing flexibility and drove investments in variable renewable energy sources (vRES) and storage, with V2X discharges rising up to 2.7-fold.
  • The time-based cost-emission ratio (TCER) and energy-based cost-emission ratio (ECER) demonstrated that price and CEF signals can be used to assess the dominance of economic vs. environmental drivers in DR decisions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.