Skip to main content
QUICK REVIEW

[Paper Review] Future plan for observation of cosmic gamma rays in the 100 TeV energy region with the Tibet air shower array : simulation and sensitivity

M. Amenomori, Xiao-Jun Bi|ArXiv.org|Oct 15, 2007
Astrophysics and Cosmic PhenomenaPhysics and Astronomy3 citations
TL;DR

This paper proposes enhancing the Tibet air shower array with a large underground water Cherenkov muon detector (MD) array to improve sensitivity to 100 TeV cosmic gamma rays by discriminating gamma-ray-induced air showers from hadronic backgrounds. Using Monte Carlo simulations (Corsika, GEANT4), the study demonstrates that the AS+MD configuration achieves 83% gamma-hadron separation efficiency at 100 TeV, enabling a 5σ sensitivity of 7% and 20% of the Crab flux above 20 and 100 TeV, respectively, surpassing current and future IACTs at high energies.

ABSTRACT

The Tibet air shower array, which has an effective area of 37,000 square meters and is located at 4300 m in altitude, has been observing air showers induced by cosmic rays with energies above a few TeV. We have a plan to add a large muon detector array to it for the purpose of increasing its sensitivity to cosmic gamma rays in the 100 TeV energy region by discriminating them from cosmic-ray hadrons. We have deduced the attainable sensitivity of the muon detector array using our Monte Carlo simulation. We report here on the detailed procedure of our Monte Carlo simulation.

Motivation & Objective

  • To improve the sensitivity of the Tibet air shower array to cosmic gamma rays in the 100 TeV energy region.
  • To address the limitation of existing air shower arrays in distinguishing gamma-ray-induced air showers from hadronic backgrounds.
  • To design and evaluate a large underground water Cherenkov muon detector array for enhanced gamma-hadron discrimination.
  • To quantify the attainable sensitivity of the upgraded Tibet AS+MD system for point-like gamma-ray sources.

Proposed method

  • Simulated air shower events from primary cosmic rays and gamma rays using Corsika Ver.6.204 with QGSJET01c for hadronic interactions and a differential energy spectrum of E^-2.6 for gamma rays.
  • Used an upgraded Tibet AS array configuration with effective area increased to 50,000 m², simulating detector responses via Epics uv8.00 for surface scintillation counters.
  • Simulated muon detection using GEANT4, modeling soil absorber (2.0 m, 2.0 g/cm³, 70% SiO₂, 20% Al₂O₃, 10% CaO) and MD array structure (concrete cells, 0.5 m ceiling, 70% reflectance).
  • Calculated photoelectron collection (N_PEs) for each muon detector, with N_PEs resolution of 34 PEs ±18% for vertical muons.
  • Applied a software trigger requiring fourfold coincidence in FT counters with >1.25 particle charge, core within array, and direction error <1.0 m.
  • Optimized a cut on ∑N_PEs (sum of N_PEs >10 per detector) to suppress hadronic events while retaining >83% of gamma-induced events at 100 TeV.

Experimental results

Research questions

  • RQ1What is the achievable sensitivity of the Tibet AS+MD array to point-like 100 TeV gamma-ray sources?
  • RQ2How effectively can the muon detector array suppress hadronic background events while preserving gamma-ray signal efficiency?
  • RQ3What is the optimal cut condition on ∑N_PEs that maximizes gamma-hadron separation at 100 TeV energies?
  • RQ4How does the sensitivity of the AS+MD system compare to existing and next-generation IACTs in the 100 TeV energy range?
  • RQ5What is the impact of detector geometry, material composition, and light collection efficiency on the final sensitivity?

Key findings

  • The AS+MD array achieves a 5σ sensitivity of 7% of the Crab flux for point-like sources above 20 TeV in one year of observation.
  • Above 100 TeV, the sensitivity reaches 20% of the Crab flux, demonstrating capability to probe the 100 TeV gamma-ray window.
  • At ∑ρ ≈ 1000 (corresponding to ~100 TeV primary gamma rays), hadronic background is suppressed to 0.01% or less while retaining 83% of gamma-induced events.
  • The muon detector system achieves a photoelectron resolution of 34 PEs with ±18% uncertainty for vertically penetrating muons.
  • The optimized cut on ∑N_PEs effectively separates gamma and hadron showers, with 83% survival efficiency for gamma events and <0.01% survival for hadronic events at 100 TeV.
  • The AS+MD system surpasses existing IACTs above 20 TeV and may exceed next-generation IACTs above 40 TeV in sensitivity at high energies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.