Skip to main content
QUICK REVIEW

[Paper Review] HEMT-based 1K front-end electronics for the heat and ionization Ge CryoCube of the future RICOCHET CE$ u$NS experiment

G. Baulieu, J. Billard|arXiv (Cornell University)|Nov 19, 2021
Dark Matter and Cosmic PhenomenaPhysics and Astronomy12 references7 citations
TL;DR

This paper presents HEMT-based front-end electronics for the 1K CryoCube detector in the RICOCHET CEνNS experiment, using low-noise HEMTs with 15 µW dissipation to achieve 10 eV RMS heat and 20 eVee RMS ionization baseline resolution. The system employs a closed-loop amplifier design with feedback on the HEMT source, enabling high linearity, stable gain (498), and bandwidth up to 40 kHz, crucial for discriminating low-energy nuclear recoils from background events.

ABSTRACT

The RICOCHET reactor neutrino observatory is planned to be installed at the Laue Langevin Institute (ILL) starting mid-2022. Its scientific goal is to perform a low-energy and high precision measurement of the coherent elastic neutrino-nucleus scattering (CE$ u$NS) spectrum in order to explore exotic physics scenarios. RICOCHET will host two cryogenic detector arrays: the CryoCube (Ge target) and the Q-ARRAY (Zn target), operated at 10 mK. The 1 kg Ge CryoCube will consist of 27 Ge crystals instrumented with NTD-Ge thermal sensors and charge collection electrodes for a simultaneous heat and ionization readout to reject the electromagnetic backgrounds (gamma, beta, x-rays). We present the status of its front-end electronics. The first stage of amplification is made of High Electron Mobility Transistor (HEMT) developed by CNRS/C2N laboratory, optimized to achieve ultra-low noise performance at 1K with a dissipation as low as 15 $\mu$W per channel. Our noise model predicts that 10 eV heat and 20 eVee RMS baseline resolutions are feasible with a high dynamic range for the deposited energy (up to 10 MeV) thanks to loop amplification schemes. Such resolutions are mandatory to have a high discrimination power between nuclear and electron recoils at the lowest energies.

Motivation & Objective

  • Develop ultra-low-noise front-end electronics for cryogenic Ge detectors in the RICOCHET CEνNS experiment to achieve sub-10 eV energy resolution.
  • Overcome the challenge of achieving 10 eV RMS heat baseline resolution and 20 eVee RMS ionization resolution for nuclear recoil discrimination at low energies.
  • Enable operation at 1 K with minimal power dissipation (15 µW per channel) and high reproducibility across 100+ HEMT devices.
  • Integrate the cold electronics close to the detector to minimize cabling capacitance and improve signal fidelity.
  • Demonstrate high linearity and stable gain in a closed-loop amplifier configuration using HEMTs as high-impedance input devices.

Proposed method

  • Use HEMTs developed by CNRS/C2N and commercialized by CryoHEMT, optimized for ultra-low noise at 1 K with 15 µW power dissipation.
  • Implement a closed-loop amplifier configuration where feedback is applied to the HEMT source, creating a non-inverting amplifier with a voltage gain of 1 + R9/R3 = 501.
  • DC-couple the NTD-Ge sensor directly to the HEMT input to avoid low-frequency roll-off and maintain flat response across the full bandwidth.
  • Employ a Howland current pump (U2) to stabilize the feedback current and ensure gain independence from cabling resistance.
  • Use a 300 K op-amp stage with feedback capacitance C1 to provide high open-loop gain and enable precise control of the amplifier response.
  • Test the amplifier at 4.2 K and 1 K in a dilution fridge, using a dummy NTD resistor to isolate HEMT noise performance.

Experimental results

Research questions

  • RQ1Can HEMT-based amplifiers achieve 10 eV RMS heat baseline resolution at 1 K with only 15 µW dissipation per channel?
  • RQ2Does the closed-loop feedback configuration on the HEMT source ensure stable gain and high linearity across a 15 MeV dynamic range of deposited energy?
  • RQ3How does the amplifier perform in terms of voltage noise and bandwidth at 1 K, particularly in the 100 Hz–10 kHz range relevant for CEνNS detection?
  • RQ4Can the HEMT-based front-end electronics be reliably scaled to 150 channels for the CryoCube array while maintaining low noise and high reproducibility?
  • RQ5To what extent does the feedback configuration mitigate the impact of cabling capacitance and resistance on amplifier performance?

Key findings

  • The HEMT-based amplifier achieves a voltage noise floor of approximately 0.5 nV/√Hz in the 100 Hz–10 kHz range at 1 K, with negligible additional noise contribution from the amplifier itself.
  • The amplifier demonstrates excellent linearity, maintaining a stable gain of 498 across the full dynamic range up to 16 mV input, corresponding to ~15 MeV deposited energy.
  • The measured bandwidth ranges from 15 kHz to 40 kHz, exceeding the RICOCHET requirements and showing no low-frequency roll-off due to DC coupling.
  • The HEMTs maintain consistent performance at 1 K with a dissipation as low as 15 µW per channel and show good reproducibility across approximately 100 tested devices.
  • The closed-loop feedback configuration successfully stabilizes the HEMT bias, ensuring constant Ids and Vds, and enables high input impedance with minimal gain drift.
  • The system is designed to support 150 channels for the CryoCube, with the potential to achieve the target 10 eV RMS heat and 20 eVee RMS ionization baseline resolution with further optimization.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.