Skip to main content
QUICK REVIEW

[Paper Review] Heteroscedastic Calibration of Uncertainty Estimators in Deep Learning

Bindya Venkatesh, Jayaraman J. Thiagarajan|arXiv (Cornell University)|Oct 30, 2019
Adversarial Robustness in Machine LearningComputer Science20 references5 citations
TL;DR

This paper proposes a single-shot calibration method that repurposes the heteroscedastic regression objective as a surrogate for calibration, enabling any existing uncertainty estimator—such as Monte Carlo dropout or quantile-based methods—to produce inherently calibrated prediction intervals without post-hoc recalibration. The approach improves both calibration and mean prediction accuracy across benchmark regression datasets.

ABSTRACT

The role of uncertainty quantification (UQ) in deep learning has become crucial with growing use of predictive models in high-risk applications. Though a large class of methods exists for measuring deep uncertainties, in practice, the resulting estimates are found to be poorly calibrated, thus making it challenging to translate them into actionable insights. A common workaround is to utilize a separate recalibration step, which adjusts the estimates to compensate for the miscalibration. Instead, we propose to repurpose the heteroscedastic regression objective as a surrogate for calibration and enable any existing uncertainty estimator to be inherently calibrated. In addition to eliminating the need for recalibration, this also regularizes the training process. Using regression experiments, we demonstrate the effectiveness of the proposed heteroscedastic calibration with two popular uncertainty estimators.

Motivation & Objective

  • To address the poor calibration of uncertainty estimators in deep learning, especially in high-risk applications like healthcare and autonomous driving.
  • To eliminate the need for separate recalibration steps that can render uncertainty estimates meaningless, as shown in prior work.
  • To enable any existing uncertainty estimator to produce well-calibrated prediction intervals through implicit calibration during training.
  • To regularize the training process, improving both uncertainty calibration and mean prediction accuracy.
  • To demonstrate the effectiveness of the method on diverse regression benchmarks using epistemic and aleatoric uncertainty estimators.

Proposed method

  • Repurpose the heteroscedastic regression objective as a surrogate for calibration, using uncertainty estimates from any existing estimator in place of model-predicted variances.
  • Optimize the Gaussian likelihood objective using estimated uncertainty (e.g., from MC dropout or quantile networks) as the variance term in the loss function.
  • For MC dropout, compute mean and variance across M forward passes with dropout; use these to compute the heteroscedastic loss.
  • For quantile-based uncertainty, train the model to predict upper and lower quantiles (τᵘ=0.9, τˡ=0.1), then estimate standard deviation as (ŷᵘ − ŷˡ)/2.
  • Jointly optimize the heteroscedastic loss with quantile prediction losses using weighted sum: λ_H·L_HNN + λ_u·L_τᵘ + λ_l·L_τˡ.
  • Use a single training pass to achieve both accurate mean predictions and well-calibrated prediction intervals, avoiding post-hoc recalibration.

Experimental results

Research questions

  • RQ1Can the heteroscedastic regression objective be repurposed as a surrogate for calibration to produce inherently calibrated uncertainty estimates?
  • RQ2Does this approach improve calibration without requiring separate recalibration steps, even when baseline estimators are poorly calibrated?
  • RQ3How does the method perform across different uncertainty estimators, such as MC dropout and quantile-based methods?
  • RQ4Does implicit calibration via the heteroscedastic objective lead to better regularization and improved mean prediction accuracy?
  • RQ5How robust is the method to hyperparameter choices, such as dropout rate p, compared to standard MC dropout?

Key findings

  • The proposed Dropout-HC and Quantile-HC methods achieve near-perfect calibration, as shown by Expected vs. Achieved Calibration Level plots that closely follow the diagonal line.
  • Both methods significantly reduce calibration error (CE) compared to baseline MC dropout and HNN across all 8 UCI regression datasets.
  • The Dropout-HC method is robust to changes in dropout rate p, unlike standard MC dropout, which shows high variability in calibration error with different p values.
  • The heteroscedastic calibration leads to a heavier-tailed distribution of uncertainty estimates (σ) compared to standard MC dropout at the same p.
  • The method improves mean prediction accuracy, as evidenced by lower RMSE values across all datasets, indicating better regularization during training.
  • The joint optimization of heteroscedastic and quantile losses enables accurate interval estimation while maintaining strong calibration performance.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.