[Paper Review] High Voltage Test Apparatus for a Neutron EDM Experiment and Lower Limit on the Dielectric Strength of Liquid Helium at Large Volumes

J. Long, J. G. Boissevain|ArXiv.org|Mar 27, 2006
Quantum, superfluid, helium dynamicsPhysics and Astronomy3 references3 citations
TL;DR

This paper presents a high-voltage test apparatus for a neutron electric dipole moment (EDM) experiment using ultracold neutrons in superfluid helium, demonstrating that normal liquid helium can sustain electric fields up to at least 90 kV cm⁻¹ over 7.5 cm gaps in a 200 L dewar, with leakage currents below 170 pA. It establishes a lower limit of 30 kV cm⁻¹ for superfluid helium, approaching 60% of the target 50 kV cm⁻¹ design field.

ABSTRACT

A new search for a permanent electric dipole moment (EDM) of the neutron is underway using ultracold neutrons produced and held in a bath of superfluid helium. Attaining the target sensitivity requires maintaining an electric field of several tens of kilovolts per centimeter across the experimental cell, which is nominally 7.5 cm wide and will contain about 4 liters of superfluid. The electrical properties of liquid helium are expected to be sufficient to meet the design goals, but little is known about these properties for volumes and electrode spacings appropriate to the EDM experiment. Furthermore, direct application of the necessary voltages from an external source to the experimental test cell is impractical. An apparatus to amplify voltages in the liquid helium environment and to test the electrical properties of the liquid for large volumes and electrode spacings has been constructed. The device consists of a large-area parallel plate capacitor immersed in a 200 liter liquid helium dewar. Preliminary results show the breakdown strength of normal state liquid helium is at least 90 kV/cm at these volumes, at the helium vapor pressure corresponding to 4.38 K. These fields hold for more than 11 hours with leakage currents less than 170 pA (about 20% of the maximum tolerable in the EDM experiment). The system is also found to be robust against anticipated radiation backgrounds. Preliminary results for superfluid show that fields of at least 30 kV/cm can be sustained at the volumes required for the EDM experiment, about 60% of the design goal. These results are likely limited by the low pressure that must be maintained above the superfluid bath.

Motivation & Objective

  • To develop a high-voltage test system capable of generating and sustaining electric fields of tens of kV cm⁻¹ in large-volume liquid helium for a neutron EDM experiment.
  • To measure the dielectric strength of normal and superfluid liquid helium under conditions relevant to the neutron EDM experiment, including large electrode spacing (7.5 cm) and volume (4 L).
  • To assess the feasibility of using liquid helium as a dielectric medium for high-voltage applications in cryogenic, ultra-low-background environments.
  • To evaluate the robustness of the system against radiation backgrounds and transient current spikes potentially caused by bubble formation.

Proposed method

  • Constructed a large-area parallel-plate capacitor immersed in a 200 L liquid helium dewar to simulate the experimental cell conditions of the neutron EDM experiment.
  • Applied high voltage using an internal voltage amplification system to avoid direct external connections to the cryogenic cell.
  • Measured breakdown strength by increasing voltage until electrical breakdown occurred, with leakage current monitored continuously.
  • Used a model based on bubble formation and capacitance change to explain transient current spikes, estimating bubble escape times from buoyant and drag forces.
  • Applied the size effect scaling law $ E_{b2} = E_{b1} (S_2/S_1)^{-1/m} $ to estimate field reduction due to increased stressed volume.
  • Calculated bubble escape time using hydrodynamic forces: buoyancy, drag ($ F_d = 12 au\eta r v $), and added mass ($ F_{m'} = \frac{1}{2} V_b \rho_l \vec{a} $), leading to equation of motion $ \vec{a} - 2g + \frac{18\eta}{r^2\rho_l} \vec{v} = 0 $.

Experimental results

Research questions

  • RQ1What is the breakdown strength of normal liquid helium at large volumes (4 L) and electrode spacing (7.5 cm) relevant to the neutron EDM experiment?
  • RQ2Can superfluid helium sustain electric fields of at least 30 kV cm⁻¹ under the same experimental conditions, approaching the target 50 kV cm⁻¹?
  • RQ3What causes the observed transient current spikes in the high-voltage system, and can they be attributed to bubble formation at electrode surfaces?
  • RQ4How long do bubbles remain in the electric field gap before escaping, and what is the expected magnitude of the recovery current after bubble detachment?
  • RQ5Is the system robust against radiation backgrounds expected in the neutron EDM experiment?

Key findings

  • The breakdown strength of normal liquid helium at 4.38 K and 7.5 cm electrode spacing is at least 90 kV cm⁻¹, exceeding the extrapolated design target.
  • Leakage currents remained below 170 pA over 11 hours, well within the 20% of maximum tolerable current for the neutron EDM experiment.
  • A lower limit of 30 kV cm⁻¹ was established for superfluid helium, representing approximately 60% of the target 50 kV cm⁻¹ field strength.
  • Transient current spikes were observed to be consistent with bubble formation at electrode surfaces, with estimated capacitance changes of 0.5–5 fF for 0.1–1 mm bubbles.
  • Bubble escape times from the gap were estimated to be at least 100 ms, with recovery current transients likely below 1 nA for most bubbles, below the system’s noise floor.
  • The model of bubble-induced capacitance changes explains the observed current transients, suggesting they do not indicate actual charge accumulation and can be filtered from data.