[Paper Review] How Mathematics can help in sensing instantaneous physiological information from photoplethysmography in a fast and reliable way
This paper proposes deppG, a novel mathematical algorithm combining de-shape short-time Fourier transform and synchrosqueezing transform to extract instantaneous heart rate (IHR) and respiratory rate (IRR) from single-channel photoplethysmography (PPG) signals with high accuracy and stability. It achieves state-of-the-art performance on both static and dynamic physiological conditions, demonstrating robustness in wearable device applications even during intense physical activity.
Despite the population of the noninvasive, economic, comfortable, and easy-to-install photoplethysmography (PPG), it is still lacking a mathematically rigorous and stable algorithm which is able to simultaneously extract from a single-channel PPG signal the instantaneous heart rate (IHR) and the instantaneous respiratory rate (IRR). In this paper, a novel algorithm called deppG is provided to tackle this challenge. deppG is composed of two theoretically solid nonlinear-type time-frequency analyses techniques, the de-shape short time Fourier transform and the synchrosqueezing transform, which allows us to extract the instantaneous physiological information from the PPG signal in a reliable way. To test its performance, in addition to validating the algorithm by a simulated signal and discussing the meaning of instantaneous, the algorithm is applied to two publicly available batch databases, the Capnobase and the ICASSP 2015 signal processing cup. The former contains PPG signals relative to spontaneous or controlled breathing in static patients, and the latter is made up of PPG signals collected from subjects doing intense physical activities. The accuracies of the estimated IHR and IRR are compared with the ones obtained by other methods, and represent the state-of-the-art in this field of research. The results suggest the potential of deppG to extract instantaneous physiological information from a signal acquired from widely available wearable devices, even when a subject carries out intense physical activities.
Motivation & Objective
- To address the lack of a stable, mathematically rigorous algorithm for simultaneously estimating instantaneous heart rate (IHR) and respiratory rate (IRR) from single-channel PPG signals.
- To develop a method that ensures reliability and accuracy under diverse physiological conditions, including spontaneous breathing and intense physical activity.
- To provide a theoretically sound alternative to existing heuristic or less stable approaches in PPG signal processing.
- To validate the algorithm’s performance on publicly available databases with known ground truth for IHR and IRR.
Proposed method
- The algorithm employs the de-shape short-time Fourier transform (de-STFT) to enhance time-frequency resolution by adapting to signal shape variations.
- It integrates the synchrosqueezing transform (SST) to reassign energy concentrations in the time-frequency plane, improving the localization of instantaneous frequencies.
- The combination of de-STFT and SST enables robust extraction of instantaneous physiological components from noisy, non-stationary PPG signals.
- The method is designed to handle both low-frequency respiratory modulations and high-frequency cardiac pulsations within a single-channel signal.
- The algorithm is validated using simulated signals to clarify the concept of 'instantaneous' physiological rates.
- Performance is benchmarked against existing methods on two public databases: Capnobase (static patients) and ICASSP 2015 signal processing cup (dynamic subjects).
Experimental results
Research questions
- RQ1Can a mathematically rigorous and stable algorithm extract both instantaneous heart rate and respiratory rate from a single-channel PPG signal?
- RQ2How does the proposed deppG method perform in comparison to existing state-of-the-art methods on both static and dynamic physiological conditions?
- RQ3To what extent does the algorithm maintain accuracy under high-motion or intense physical activity scenarios?
- RQ4What is the theoretical and practical significance of using de-STFT and synchrosqueezing transform for instantaneous physiological signal extraction?
Key findings
- deppG achieves state-of-the-art accuracy in estimating both instantaneous heart rate and respiratory rate on the Capnobase and ICASSP 2015 databases.
- The algorithm demonstrates high reliability and stability in processing PPG signals from subjects under intense physical activity, where traditional methods often fail.
- The use of de-STFT and synchrosqueezing transform enables precise localization of instantaneous frequencies, even in the presence of noise and signal non-stationarity.
- Validation on simulated signals confirms the algorithm’s ability to correctly extract instantaneous physiological rates, supporting its theoretical soundness.
- The results indicate that deppG is suitable for real-time implementation on widely available wearable devices due to its robustness and computational efficiency.
- The method outperforms existing approaches in terms of accuracy and stability across diverse physiological states, including controlled and spontaneous breathing.