[Paper Review] Impact of street canyon morphology on heat and fluid flow-an experimental water tunnel study using simultaneous PIV-LIF technique
This study investigates the impact of street canyon morphology on heat and fluid flow using a large-scale water tunnel with simultaneous PIV and LIF to measure velocity and temperature fields at high resolution. Results show that canyon aspect ratio critically controls ventilation rates (0.02–1.5) and heat flux, with the local Richardson number accurately describing buoyant heat removal at the roof level.
Urban areas are known for their complex atmospheric environments, with the building morphology having a significant impact on local climate patterns, air quality, and overall urban microclimate. Understanding the heat transport and fluid flow in complex urban environments is crucial for improving urban climate resilience, which remains an open frontier in the field of urban studies. To gain a more profound insight into the physical processes occurring in urban areas, particularly within street canyons, we conducted an experimental investigation in a large-scale water tunnel. This study involved the simultaneous examination of heat and flow fields, carried out at high spatial and temporal resolutions, utilizing Laser-induced Fluorescence (LIF) for heat analysis and Particle Image Velocimetry (PIV) for flow analysis. Our results of heat and flow in different street canyons indicate that the flow is significantly influenced by a combination of factors, including canyon configuration, the presence of buoyant force, and the magnitude of the approaching flow. The ventilation rate and heat flux from the street canyon, which are key factors shaping the urban microclimate, are found dominated significantly by the street canyon morphology. For instance, changing the aspect ratio of a street canyon results in a significant change of air ventilation rate, ranging from as low as 0.02 to as high as 1.5 under the same flow conditions. Additionally, canyons with high air ventilation rates exhibit significant heat flux removal at the canyon roof level, which is accurately described by the local Richardson number.
Motivation & Objective
- To understand how urban street canyon morphology influences fluid flow and heat transport in complex urban microclimates.
- To address the gap in high-resolution, simultaneous measurement of velocity and temperature fields in buoyant flows within street canyons.
- To quantify the effects of canyon aspect ratio, buoyancy, and approaching flow on air ventilation and heat flux.
- To validate the role of the local Richardson number in describing heat flux removal at canyon roofs.
- To provide experimental data for improving urban climate modeling and sustainable urban design.
Proposed method
- Conducted experiments in a large-scale closed-circuit water tunnel to simulate urban street canyon flows under controlled thermal and flow conditions.
- Employed simultaneous Particle Image Velocimetry (PIV) for high-resolution 2D velocity field measurement and Laser-Induced Fluorescence (LIF) for temperature field reconstruction.
- Used 3D parametric urban models mimicking Singapore’s urban morphology to represent realistic building configurations.
- Varied canyon aspect ratios (height-to-width ratios) and applied bottom heating to induce thermal buoyancy forces.
- Measured flow and thermal fields at high spatial and temporal resolution to capture complex vortex structures and thermal stratification.
- Calculated local Richardson number to correlate buoyancy effects with heat flux at canyon roof levels.
Experimental results
Research questions
- RQ1How does street canyon aspect ratio influence air ventilation rate and flow structure in the presence of thermal buoyancy?
- RQ2To what extent does buoyancy force alter velocity and temperature fields in street canyons compared to neutral flow conditions?
- RQ3How does canyon morphology affect heat flux removal at the roof level, and can this be quantified using the local Richardson number?
- RQ4What is the relationship between flow structure, ventilation efficiency, and thermal stratification in 3D urban street canyons?
- RQ5How do simultaneous PIV and LIF measurements improve the resolution and accuracy of heat and flow field characterization compared to point sensors?
Key findings
- Canyon aspect ratio significantly alters air ventilation rates, ranging from as low as 0.02 to as high as 1.5 under identical flow conditions.
- Canyons with high ventilation rates exhibit strong heat flux removal at the roof level, indicating efficient thermal dissipation.
- The local Richardson number effectively describes the magnitude and distribution of heat flux at the canyon roof, linking buoyancy to thermal transport.
- Buoyant forces substantially modify flow structures, including the formation of corner vortices and horseshoe vortices, especially in low-aspect-ratio canyons.
- Simultaneous PIV-LIF measurements revealed detailed, high-resolution flow and thermal fields that expose complex interactions between geometry, buoyancy, and flow dynamics.
- The study demonstrates that morphological design—particularly aspect ratio—plays a dominant role in shaping urban microclimate by controlling ventilation and heat removal.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.