Skip to main content
QUICK REVIEW

[Paper Review] In-flight calibration of RADEM, the JUICE mission radiation monitor

Marco Pinto, Francisca Santos|arXiv (Cornell University)|Feb 27, 2026
Ionosphere and magnetosphere dynamicsPhysics and Astronomy0 citations
TL;DR

The paper presents an in-flight calibration campaign for RADEM on JUICE, deriving calibration coefficients to convert detector counts into particle fluxes using GCRs and a BON2020 model, and validating proton SEP flux reconstruction against SOHO/ERNE measurements.

ABSTRACT

The RADiation-hard Electron Monitor (RADEM) aboard the Jupiter Icy Moons Explorer (JUICE), launched on 14 April 2023, measures high-energy protons and electrons during the cruise phase and will continue throughout the nominal mission. Initial in-flight observations could not be explained by pre-flight ground calibration, motivating an in-flight calibration campaign. We calibrated the RADEM sensors using galactic cosmic rays by progressively increasing detector thresholds, thereby modifying their response to high-energy particles. Threshold-dependent in-flight count rates were compared with theoretical expectations derived from the Badhwar-O'Neill 2020 galactic cosmic ray model and corresponding response functions. These results were used to derive new in-flight calibration coefficients and to develop a flux reconstruction algorithm based on the bow-tie method. In several cases, the in-flight calibration slopes differ by up to an order of magnitude from ground calibration values. Proton fluxes from solar energetic particle events reconstructed with this method agree within a factor of two with independent measurements from the Solar and Heliospheric Observatory. These results demonstrate that RADEM provides accurate proton flux measurements in interplanetary space and is well suited for both single-spacecraft analyses and coordinated multi-mission studies of solar energetic particles. While electrons were clearly detected during the JUICE Lunar-Earth gravity assist, reliable reconstruction of their fluxes requires further analysis.

Motivation & Objective

  • Explain why ground calibration failed to reproduce flight observations for RADEM and motivate in-flight recalibration.
  • Describe the calibration workflow that links detector thresholds to energy deposits via response functions.
  • Develop a flux-reconstruction method (bow-tie approach) to convert detector counts to incident particle fluxes.
  • Estimate in-flight calibration coefficients for RADEM sensor thresholds and validate proton fluxes against external datasets.

Proposed method

  • Compute RADEM response functions for GCR species using Geant4 with a simplified spacecraft shielding model.
  • Use BON2020 GCR fluxes at 1 au with a modulating potential phi ~ 1000 MV to match flight data during May 2024.
  • Simulate count rates as a function of energy thresholds for RADEM detector heads and compare to flight counts to derive calibration coefficients.
  • Apply a bow-tie based flux-reconstruction algorithm to translate RADEM counts into differential fluxes.
  • Handle SEP contamination by analyzing Run 1 and Run 2 data and excluding contaminated intervals from calibration.

Experimental results

Research questions

  • RQ1Can in-flight calibration reproduce RADEM count rates observed in flight across different thresholds?
  • RQ2What are the appropriate DAC-to-energy threshold conversions for RADEM sensors when using GCRs as a calibration source?
  • RQ3How do calibration coefficients differ from ground-based results, and what are the implications for flux reconstruction?
  • RQ4How well do RADEM-derived proton fluxes match independent measurements (e.g., SOHO/ERNE) for SEP events and quiet periods?

Key findings

  • New in-flight calibration coefficients were derived for all RADEM sensors.
  • In several cases, in-flight calibration slopes differ by up to an order of magnitude from pre-flight ground values.
  • Proton fluxes from SEP events reconstructed with the bow-tie method agree with SOHO/ERNE measurements within a factor of two.
  • RADEM can provide accurate proton flux measurements in interplanetary space and support multi-mission SEP studies.
  • Electrons are identifiable in JUICE LEGA measurements, but flux reconstruction requires more detailed analysis.
  • Calibration revealed that HGLT/HGHT slopes vary with detector and threshold due to electronics and shielding modeling limitations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.