TL;DR

The paper reanalyzes ambient fume-hood temperature data from a 254-hour self-discharge test to infer the charging cycles of co-located devices, revealing a ~40-minute cycle with ~22 min charge and ~18 min discharge at 3C, and evidence of at least 338 cycles with no detectable degradation.

ABSTRACT

I present a reanalysis of temperature data from a publicly available certified laboratory report that documented the self-discharging behavior of an energy-storage device during 10 days. Graphs of temperature variations of both the tested device itself and the test chamber (fume hood) were given mainly for monitoring without further analysis, and variations in the ambient temperature signal were attributed to "other cells being cycled simultaneously in the same fume hood". I show that the ambient temperature signal alone -- together with some quite mild and reasonable assumptions -- allow to extract previously unpublished information on the simultaneously run test on the other cells: 1) the number of charge/discharge cycles 2) the cycle period, 3) the charge/discharge half-cycle asymmetry, and -- most significantly -- evidence that 4) the mentioned "other device" completed 338 full charge/discharge cycles at 3C rate at room temperature without any detectable thermal degradation signature.

Motivation & Objective

  • Motivate non-invasive thermal monitoring to understand cycling behavior in energy-storage devices.
  • Demonstrate that ambient temperature data can reveal cycling parameters without modifying the test setup.
  • Extract cycling frequency, half-cycle durations, and asymmetry from non-contact measurements.

Proposed method

  • Extract temperature traces from published figures by converting PDFs to SVG and parsing path data.
  • Detrend slow baseline drift with clamped cubic splines and local scaling to align segments.
  • Compute one-sided DFT amplitudes on uniformly sampled detrended signals to identify harmonic structure.
  • Identify alternating half-cycles by locating peaks in the detrended signal and separating even/odd intervals.
  • Interpret the harmonic spectrum to infer a fundamental cycle and its harmonics, linking to a ~40 min cycle with ~22/18 min half-cycles.

Experimental results

Research questions

  • RQ1Can ambient fume-hood temperature fluctuations be used to non-invasively infer the cycling behavior of co-located energy-storage devices?
  • RQ2What are the cycle period, half-cycle durations, and asymmetry in the observed cycling from ambient temperature data?
  • RQ3Is there evidence of degradation or aging over hundreds of cycles based solely on ambient-temperature signals?

Key findings

  • The detrended ambient temperature data show a dominant ~40-minute cycle, with a ~20-minute period corresponding to the second harmonic (≈3.0 h^-1) and a ~13-minute third harmonic (≈4.5 h^-1).
  • Five analyzed segments (~254 hours total) exhibit consistent oscillations with a ~22-minute charge half-cycle and ~18-minute discharge half-cycle; Δ(T_charge−T_discharge) ≈ 4 minutes remains stable.
  • The cycle counts across segments indicate ~30 cycles in ZE/ZL and OI/OL subsets; across OE, OI, OL segments the record covers ~332 cycles with similar amplitude and period.
  • Amplitude shows a consistent sawtooth-like heating pattern with peaks exceeding troughs by roughly 19–31% across segments.
  • The analysis infers a 3C cycling rate and suggests a relaxation pause in the protocol, though the exact driving protocol cannot be confirmed from ambient data alone.
  • Across the full 254-hour run, amplitude and period remain stable with no detectable degradation signature in the indirect ambient signal.