[Paper Review] Inferences on mass composition and tests of hadronic interactions from 0.3 to 100 EeV using the water-Cherenkov detectors of the Pierre Auger Observatory

A. Aab, P. Abreu|arXiv (Cornell University)|Dec 15, 2017
Particle physics theoretical and experimental studiesPhysics and Astronomy1 citations
TL;DR

This study introduces a novel method using risetimes in water-Cherenkov detector signals to infer mass composition and test hadronic interaction models at ultrahigh energies (0.3–100 EeV). By calibrating a new parameter against fluorescence data, it derives Xmax for over 81,000 events—14× more than previous fluorescence samples—extending the energy range and reducing statistical uncertainty in mass composition inferences.

ABSTRACT

We present a new method for probing the hadronic interaction models at ultrahigh energy and extracting details about mass composition. This is done using the time profiles of the signals recorded with the water-Cherenkov detectors of the Pierre Auger Observatory. The profiles arise from a mix of the muon and electromagnetic components of air showers. Using the risetimes of the recorded signals, we define a new parameter, which we use to compare our observations with predictions from simulations. We find, first, inconsistencies between our data and predictions over a greater energy range and with substantially more events than in previous studies. Second, by calibrating the new parameter with fluorescence measurements from observations made at the Auger Observatory, we can infer the depth of shower maximum Xmax for a sample of over 81,000 events extending from 0.3 to over 100 EeV. Above 30 EeV, the sample is nearly 14 times larger than what is currently available from fluorescence measurements and extending the covered energy range by half a decade. The energy dependence of ?Xmaxcopyright is compared to simulations and interpreted in terms of the mean of the logarithmic mass. We find good agreement with previous work and extend the measurement of the mean depth of shower maximum to greater energies than before, reducing significantly the statistical uncertainty associated with the inferences about mass composition.

Motivation & Objective

  • To develop a new method for probing hadronic interaction models at ultrahigh energies using water-Cherenkov detector signal time profiles.
  • To infer the depth of shower maximum (Xmax) from risetimes without relying solely on fluorescence detectors.
  • To extend the energy range and statistical significance of Xmax measurements beyond current fluorescence-based samples.
  • To reduce uncertainties in mass composition inferences by leveraging a larger, more sensitive event sample.

Proposed method

  • Analyzes time profiles of signals recorded by water-Cherenkov detectors to extract risetime information from air shower components.
  • Defines a new parameter based on risetimes to characterize the muon and electromagnetic components of air showers.
  • Calibrates the new parameter using co-located fluorescence measurements from the Pierre Auger Observatory.
  • Uses the calibrated parameter to infer Xmax for over 81,000 events across 0.3–100 EeV.
  • Compares inferred Xmax values with simulations to assess consistency and infer mean logarithmic mass.
  • Applies statistical methods to reduce uncertainty in mass composition estimates at high energies.

Experimental results

Research questions

  • RQ1Can risetimes in water-Cherenkov signals provide a reliable proxy for Xmax in ultrahigh-energy air showers?
  • RQ2How do the inferred Xmax values compare with predictions from current hadronic interaction models?
  • RQ3To what extent does the new method extend the energy range and event statistics of Xmax measurements compared to fluorescence-based techniques?
  • RQ4What is the energy dependence of the mean logarithmic mass as inferred from the extended Xmax sample?
  • RQ5How do inconsistencies between data and simulations evolve across the 0.3–100 EeV energy range?

Key findings

  • The study identifies inconsistencies between observed data and simulation predictions over a broader energy range and with significantly more events than in prior studies.
  • The new method enables Xmax inference for over 81,000 events, extending the energy range from 0.3 to over 100 EeV.
  • Above 30 EeV, the Xmax sample is nearly 14 times larger than the current fluorescence-based sample.
  • The energy dependence of ⟨Xmax⟩ is measured with significantly reduced statistical uncertainty compared to previous work.
  • Good agreement is found between the inferred mean logarithmic mass and previous measurements, validating the method’s consistency.
  • The method provides a robust, high-statistics alternative to fluorescence measurements for probing mass composition and hadronic models at ultrahigh energies.