Skip to main content
QUICK REVIEW

[Paper Review] Long-Bone Fracture Detection using Artificial Neural Networks based on Contour Features of X-ray Images

Alice Yi Yang, Ling Cheng|arXiv (Cornell University)|Feb 21, 2019
AI in cancer detectionComputer Science16 references12 citations
TL;DR

This paper proposes two contour-based artificial neural network (ANN) schemes—Standard and improved Contour Histogram Feature-Based (CHFB)—for long-bone fracture detection in X-ray images, using 19 extracted contour features including gradient occurrences and 0° gradient-based region separation. The improved CHFB scheme, which excludes flesh contours, achieves 82.98% average accuracy and AUC of 0.8275, outperforming the standard version in sensitivity and false negative control.

ABSTRACT

The following paper proposes two contour-based fracture detection schemes. The development of the contour-based fracture is based on the line-based fracture detection schemes proposed in arXiv:1902.07458. Existing Computer Aided Diagnosis (CAD) systems commonly employs Convolutional Neural Networks (CNN), although the cost to obtain a high accuracy is the amount of training data required. The purpose of the proposed schemes is to obtain a high classification accuracy with a reduced number of training data through the use of detected contours in X-ray images. There are two contour-based fracture detection schemes. The first is the Standard Contour Histogram Feature-Based (CHFB) and the second is the improved CHFB scheme. The difference between the two schemes is the removal of the surrounding detected flesh contours from the leg region in the improved CHFB scheme. The flesh contours are automatically classified as non-fractures. The contours are further refined to give a precise representation of the image edge objects. A total of 19 features are extracted from each refined contour. 8 out of the 19 features are based on the number of occurrences for particular detected gradients in the contour. Moreover, the occurrence of the 0-degree gradient in the contours are employed for the separation of the knee, leg and foot region. The features are a summary representation of the contour, in which it is used as inputs into the Artificial Neural Network (ANN). Both Standard CHFB and improved CHFB schemes are evaluated with the same experimental set-ups. The average system accuracy for the Standard CHFB scheme is 80.7%, whilst the improved CHFB scheme has an average accuracy of 82.98%. Additionally, the hierarchical clustering technique is adopted to highlight the fractured region within the X-ray image, using extracted 0-degree gradients from fractured contours.

Motivation & Objective

  • To reduce reliance on large training datasets in medical X-ray fracture detection by leveraging contour-based features instead of raw pixel data.
  • To improve classification accuracy and sensitivity in fracture detection using artificial neural networks with minimal data requirements.
  • To distinguish fractured from non-fractured contours by refining edge representations and removing irrelevant soft-tissue contours.
  • To enhance visual localization of fracture regions using hierarchical clustering of 0° gradient features from detected contours.
  • To minimize false negatives—critical in clinical settings—by optimizing feature selection and clustering strategies.

Proposed method

  • Extract contours from X-ray images using edge detection and refine them to eliminate redundant or duplicated points.
  • Extract 19 features per contour, including frequency of specific gradient orientations (especially 0° gradients) to identify anatomical regions like knee, leg, and foot.
  • Apply Principal Component Analysis (PCA) to identify dominant features that best differentiate fractured from non-fractured contours.
  • Train an Artificial Neural Network (ANN) on contour features to classify each contour as fractured or non-fractured.
  • Use hierarchical clustering on 0° gradient points from detected fractured contours to highlight and localize the fracture region in the image.
  • Implement a dual evaluation: one with image-contextualized contours and one with randomly selected, non-contextualized contours to test generalization.

Experimental results

Research questions

  • RQ1Can contour-based feature extraction reduce the data requirements for training accurate fracture detection models in X-ray imaging?
  • RQ2How does removing non-bone (flesh) contours improve the performance and sensitivity of an ANN-based fracture detection system?
  • RQ3To what extent do 0° gradient features in contours aid in localizing the fracture region through hierarchical clustering?
  • RQ4How does the inclusion of image context during contour classification affect the overall system accuracy and robustness?
  • RQ5Can the false negative rate be minimized in a contour-based ANN system without sacrificing specificity or overall accuracy?

Key findings

  • The improved CHFB scheme achieved an average accuracy of 82.98%, outperforming the standard CHFB scheme’s 80.7% across both evaluations.
  • The improved CHFB scheme demonstrated superior sensitivity with a false negative to false positive ratio of 1:0.94, compared to 1:0.71 in the standard scheme.
  • The improved CHFB scheme recorded an AUC of 0.8275, slightly higher than the standard scheme’s AUC of 0.8225, indicating better true positive detection performance.
  • The maximum accuracy achieved by the improved CHFB scheme was 89.07%, suggesting potential for further improvement with enhanced data labeling.
  • Hierarchical clustering of 0° gradient points effectively highlighted the fractured region, though contour-based localization alone was insufficient due to overextension into non-fractured areas.
  • False positives were reduced in the improved scheme, but false negatives remained a challenge, indicating room for refinement in feature selection and clustering level adaptation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.