[Paper Review] Measurement of camera image sensor depletion thickness with cosmic rays
This paper presents a novel method to measure the depletion thickness of camera image sensors in consumer smartphones using cosmic-ray muon tracks. By analyzing the distribution of track lengths in the HTC Wildfire S, the authors determine the depletion thickness to be between 13.9 μm and 27.7 μm, validating the use of smartphone sensors for directional cosmic-ray detection and enabling future particle direction reconstruction with calibrated devices.
Camera image sensors can be used to detect ionizing radiation in addition to optical photons. In particular, cosmic-ray muons are detected as long, straight tracks passing through multiple pixels. The distribution of track lengths can be related to the thickness of the active (depleted) region of the camera image sensor through the known angular distribution of muons at sea level. We use a sample of cosmic-ray muon tracks recorded by the Distributed Electronic Cosmic-ray Observatory to measure the thickness of the depletion region of the camera image sensor in a commercial smart phone, the HTC Wildfire S. The track length distribution prefers a cosmic-ray muon angular distribution over an isotropic distribution. Allowing either distribution, we measure the depletion thickness to be between 13.9~$μ$m and 27.7~$μ$m. The same method can be applied to additional models of image sensor. Once measured, the thickness can be used to convert track length to incident polar angle on a per-event basis. Combined with a determination of the incident azimuthal angle directly from the track orientation in the sensor plane, this enables direction reconstruction of individual cosmic-ray events.
Motivation & Objective
- To measure the depletion thickness of a commercial smartphone camera sensor using cosmic-ray muon tracks.
- To validate the use of consumer-grade CMOS sensors as detectors for ionizing radiation, particularly cosmic-ray muons.
- To enable directional reconstruction of cosmic-ray muons by combining track length and orientation data.
- To demonstrate that smartphone-based networks like DECO can provide high-precision, large-scale cosmic-ray monitoring.
- To calibrate sensor parameters not publicly available through standard specifications.
Proposed method
- Utilize the Distributed Electronic Cosmic-ray Observatory (DECO) network to collect continuous camera images from smartphones.
- Apply an online CPU filter to identify particle candidates based on pixel amplitude thresholds and multiplicity (typically ≥5 pixels).
- Model the track length distribution using two theoretical forms: one assuming isotropic particle incidence and another based on the known sea-level cosmic-ray muon angular distribution.
- Fit the observed track length distribution to both models, using the depletion thickness H as a free parameter to determine the best-fit value.
- Derive analytical expressions for dN/dL (number of tracks per unit length) under both isotropic and cosmic-ray angular distributions, incorporating geometric factors and trigonometric dependencies on H and L.
- Use the likelihood ratio test to compare model fits and prefer the cosmic-ray angular distribution over isotropic, confirming the physical validity of the measurement.
Experimental results
Research questions
- RQ1What is the depletion thickness of the image sensor in the HTC Wildfire S smartphone as measured by cosmic-ray muon tracks?
- RQ2Does the observed track length distribution favor a cosmic-ray muon angular distribution or an isotropic distribution?
- RQ3Can smartphone camera sensors be reliably used to reconstruct the incident direction of cosmic-ray muons?
- RQ4To what extent can consumer devices with varying noise and signal processing characteristics be calibrated for particle detection?
- RQ5Can the method be generalized to other smartphone models to enable directional cosmic-ray monitoring at scale?
Key findings
- The depletion thickness of the HTC Wildfire S sensor is measured to be between 13.9 μm and 27.7 μm, with the cosmic-ray angular distribution preferred over isotropic.
- The track length distribution is significantly better described by the known cosmic-ray muon angular distribution than by an isotropic model, indicating physical consistency.
- The method enables per-event reconstruction of the incident polar angle of muons using the measured depletion thickness and track length.
- The azimuthal angle is determined directly from the track orientation in the sensor plane, allowing full 3D direction reconstruction when combined with polar angle.
- Front-back asymmetry in track brightness may help resolve directional ambiguities along the track axis, suggesting potential for improved reconstruction.
- The approach opens the door to detecting the East-West effect and possibly extensive air showers through large-scale device coincidence in future studies.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.