[Paper Review] Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
This paper presents a re-evaluated measurement of the scintillation response of CsI[Na] to low-energy nuclear recoils using tagged neutron scattering and endpoint techniques, confirming the linearity of the H11934-200 PMT and demonstrating that systematic effects in SPE fitting models—particularly Gaussian vs. exponential-Gaussian models—can introduce up to ~10% bias in absolute light yield estimates, though quenching factor (QF) values remain unaffected due to cancellation of SPE mean uncertainties.
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.
Motivation & Objective
- To re-measure the scintillation response of CsI[Na] to low-energy nuclear recoils (3–60 keV) with improved systematic control.
- To resolve discrepancies in prior COHERENT QF measurements that contributed to uncertainty in the first CEvNS observation.
- To assess the impact of photomultiplier tube (PMT) non-linearity and SPE fitting model choice on absolute light yield estimation.
- To validate the linearity of the H11934-200 PMT across the relevant signal range and correct for systematic biases in signal scale calibration.
- To update uncertainty estimates for future precision tests of coherent elastic neutrino-nucleus scattering (CEvNS).
Proposed method
- Employed tagged neutron elastic scattering to identify nuclear recoil energies via incident neutron energy and scattering angle, using Equation 1.1 and 1.2 to calculate ΔE.
- Applied the endpoint technique to measure the maximum nuclear recoil energy (θ = 180°), enabling calibration across a continuous NR energy spectrum.
- Used gamma-ray calibration lines (59.5 keV, 356.0 keV, 662 keV) to establish the electron recoil (ER) signal scale for QF determination.
- Fitted single-photoelectron (SPE) charge distributions using multiple models: Gaussian, exponential-Gaussian (Eq. B.4), and others from literature to assess model dependence.
- Evaluated PMT response across bias voltages from -880 V to -1050 V, comparing signal size in photoelectrons (PE) using different SPE fitting models.
- Quantified the impact of SPE model choice on absolute light yield estimates, particularly noting that Gaussian models underestimate SPE mean at high gains.
Experimental results
Research questions
- RQ1How does the choice of SPE charge distribution model affect the estimation of absolute light yield in CsI[Na] scintillation measurements?
- RQ2To what extent do systematic effects in PMT response and SPE fitting bias the absolute signal scale, and how do they impact QF values?
- RQ3Is the H11934-200 PMT response linear across the signal range relevant to low-energy nuclear recoils?
- RQ4What corrections are necessary to reconcile discrepancies in prior COHERENT QF measurements for CsI[Na]?
- RQ5How do updated uncertainties in light yield and QF affect the precision of future CEvNS experiments?
Key findings
- The H11934-200 PMT response is confirmed to be linear in the relevant signal range, with no evidence of non-linear behavior across bias voltages from -880 V to -1050 V.
- A ~10% bias in absolute light yield estimates arises from using a Gaussian SPE model at high PMT gains, due to poor fit in the valley region and pedestal contamination.
- Alternative SPE models, such as the exponential-Gaussian (Eq. B.4), yield a trend opposite to the Gaussian model, indicating that SPE fitting choice can significantly affect signal size in PE.
- The mean SPE charge estimate at -1050 V is constrained to within ±4% uncertainty, based on the charge distribution from 7 pVs to 187 pVs.
- While absolute light yield estimates are sensitive to SPE model choice, the quenching factor (QF) values are unaffected because the SPE mean cancels out in the QF definition.
- Updated uncertainty estimates for the CEvNS event rate in the COH-CsI experiment are revised due to corrected systematic effects, improving precision for future CEvNS tests.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.