Skip to main content
QUICK REVIEW

[Paper Review] Measurement of the inclusive electron spectrum in charmless semileptonic B decays near the kinematic endpoint and determination of |Vub|

B. Aubert, P. Tan|ArXiv.org|Aug 16, 2004
Particle physics theoretical and experimental studiesPhysics and Astronomy7 citations
TL;DR

This paper presents a preliminary measurement of the inclusive electron spectrum in charmless semileptonic B decays near the kinematic endpoint using 88 million B⁰B̄⁰ events from the B A B AR experiment. The partial branching fraction in the 2.0–2.6 GeV/c electron momentum range is measured as Δℬ = (0.480 ± 0.029_stat ± 0.053_syst) × 10⁻³, leading to a determination of |V_ub| = (3.94 ± 0.25_exp ± 0.37_fᵤ ± 0.19_theory) × 10⁻³, improving experimental precision on this CKM matrix element.

ABSTRACT

We study the inclusive electron spectrum of B->X_u e nu decays near the kinematic limit for B->X_c e nu transitions using a sample of 88 million Upsilon(4S) decays recorded by the BABAR detector at the PEP II e+e- storage rings. For the electron momentum interval of 2.0 - 2.6 GeV/c the partial branching fraction is measured to be DeltaB(B->X_u e nu) = (0.480 +/- 0.029_{stat} +/- 0.053_{syst})x10^{-3}. Combining this result on with measurements of the inclusive photon spectrum in B->X_s gamma transition we find |V_ub|=(3.94 +/- 0.25_{exp} +/- 0.37_{f_u} +/- 0.19_{theory})x10^{-3}, where the first error represents the combined statistical and systematic experimental uncertainty of the partial branching fraction measurement, the second refers to the uncertainty of the determination of the fraction f_u of the inclusive electron spectrum that falls within our cuts, and the third error is due to theoretical uncertainties in the QCD corrections, plus the uncertainty in the b-quark mass. All results are preliminary.

Motivation & Objective

  • To measure the inclusive electron spectrum in charmless semileptonic B decays (B → Xᵤeν) near the kinematic endpoint to improve the determination of the CKM matrix element |V_ub|.
  • To reduce experimental uncertainty in the partial branching fraction by selecting electrons with momentum between 2.0 and 2.6 GeV/c, minimizing contributions from B → Xc eν decays.
  • To combine the measured partial branching fraction with inclusive photon spectrum data from B → Xsγ decays to extract |V_ub| with improved precision.
  • To assess the impact of theoretical uncertainties in QCD corrections and b-quark mass on the final |V_ub| determination.
  • To evaluate the sensitivity of the result to shape-function parameters derived from B → Xsγ spectra, particularly from recent Belle and CLEO measurements.

Proposed method

  • Analyze 88 million B⁰B̄⁰ events collected by the B A B AR detector at PEP-II e⁺e⁻ storage rings to study B → Xᵤeν decays near the kinematic endpoint.
  • Apply kinematic cuts to isolate electrons with momentum between 2.0 and 2.6 GeV/c, minimizing contamination from B → Xc eν decays.
  • Measure the partial branching fraction Δℬ(B → Xᵤeν) in this momentum range using event reconstruction and particle identification techniques.
  • Combine the measured Δℬ with the fraction fᵤ of the inclusive electron spectrum attributed to B → Xᵤeν, derived from the B → Xsγ photon spectrum measured by CLEO.
  • Use theoretical calculations of QCD corrections and b-quark mass to translate the measured branching fraction into a value for |V_ub|.
  • Propagate experimental, fᵤ, and theoretical uncertainties through the extraction procedure to obtain a final |V_ub| with error breakdown.

Experimental results

Research questions

  • RQ1What is the partial branching fraction for B → Xᵤeν decays in the electron momentum range 2.0–2.6 GeV/c near the kinematic endpoint?
  • RQ2How precisely can |V_ub| be determined using the inclusive electron spectrum in charmless semileptonic B decays?
  • RQ3What is the impact of theoretical uncertainties in QCD corrections and b-quark mass on the |V_ub| determination?
  • RQ4How do different shape-function parameters from B → Xsγ spectra (e.g., CLEO vs. Belle) affect the extracted |V_ub| value?
  • RQ5To what extent does the experimental uncertainty in fᵤ, the fraction of electrons from B → Xᵤeν, limit the precision of |V_ub|?

Key findings

  • The partial branching fraction for B → Xᵤeν decays in the electron momentum range 2.0–2.6 GeV/c is measured as Δℬ = (0.480 ± 0.029_stat ± 0.053_syst) × 10⁻³.
  • Combining this result with the CLEO measurement of fᵤ from B → Xsγ decays yields |V_ub| = (3.94 ± 0.25_exp ± 0.37_fᵤ ± 0.19_theory) × 10⁻³, with the first error representing total experimental uncertainty.
  • Using the more recent Belle measurement of b → sγ spectrum parameters (a = 2.27, m_b^SF = 4.62 GeV/c²), the |V_ub| value increases to (4.40 ± 0.24_exp ± 0.28_fᵤ ± 0.21_theory) × 10⁻³ for the 2.0–2.6 GeV/c interval.
  • The partial branching fraction increases to Δℬ = 0.531 × 10⁻³ when using Belle shape-function parameters, reflecting a higher predicted contribution from B → Xᵤeν decays.
  • The total branching fraction for B → Xᵤeν is estimated as 2.16 × 10⁻³ with Belle parameters, consistent with previous expectations within uncertainties.
  • Theoretical uncertainties in QCD corrections and b-quark mass contribute the largest systematic error in the final |V_ub| determination, highlighting the need for improved theoretical modeling.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.