Skip to main content
QUICK REVIEW

[Paper Review] Measurement of the ionization yield from nuclear recoils in liquid xenon between 0.3 -- 6 keV with single-ionization-electron sensitivity

B. G. Lenardo, Jingke Xu|arXiv (Cornell University)|Aug 1, 2019
Dark Matter and Cosmic PhenomenaPhysics and Astronomy8 citations
TL;DR

This study presents the first direct measurement of nuclear recoil ionization yield in liquid xenon down to 0.3 keV, achieving single-electron sensitivity. It reveals a decreasing ionization yield at low energies and a measurable field dependence, significantly improving low-energy calibration precision for dark matter and neutrino detection experiments.

ABSTRACT

Dual-phase xenon TPC detectors are a highly scalable and widely used technology to search for low-energy nuclear recoil signals from WIMP dark matter or coherent nuclear scattering of $\\sim$MeV neutrinos. Such experiments expect to measure O(keV) ionization or scintillation signals from such sources. However, at $\\sim1\\,$keV and below, the signal calibrations in liquid xenon carry large uncertainties that directly impact the assumed sensitivity of existing and future experiments. In this work, we report a new measurement of the ionization yield of nuclear recoil signals in liquid xenon down to 0.3$\\,$keV$\\,\\,$-- the lowest energy calibration reported to date -- at which energy the average event produces just 1.1~ionized~electrons. Between 2 and 6$\\,$keV, our measurements agree with existing measurements, but significantly improve the precision. At lower energies, we observe a decreasing trend that deviates from simple extrapolations of existing data. We also study the dependence of ionization yield on the applied drift field in liquid xenon between 220V/cm and 6240V/cm, allowing these measurements to apply to a broad range of current and proposed experiments with different operating parameters.

Motivation & Objective

  • To calibrate nuclear recoil ionization yield in liquid xenon at energies below 1 keV, where existing data are sparse and uncertain.
  • To measure the ionization yield with single-electron sensitivity, enabling detection threshold characterization for low-mass WIMP and CEνNS experiments.
  • To investigate the dependence of ionization yield on applied electric field (220–6240 V/cm) for broader applicability to experimental designs.
  • To provide high-precision data to improve simulation models like NEST, particularly for ultra-low-energy ionization processes.
  • To reduce uncertainties in energy scale calibration that directly impact sensitivity in direct dark matter and neutrino detection.

Proposed method

  • Utilized fixed-angle neutron scattering from a 252Cf source to produce monoenergetic nuclear recoils in liquid xenon.
  • Employed a dual-phase time projection chamber (TPC) with high electron extraction efficiency and single-electron triggering capability.
  • Applied strong background rejection techniques to isolate nuclear recoil events with minimal ionization yield.
  • Measured ionization yield as a function of recoil energy from 0.3 to 6.1 keV, with energy resolution sufficient to detect single-electron events.
  • Varied the drift electric field from 220 V/cm to 6240 V/cm to study field dependence of ionization yield.
  • Calibrated the detector using known neutron energy spectra and compared results to NEST simulations and prior LUX data.

Experimental results

Research questions

  • RQ1What is the ionization yield of nuclear recoils in liquid xenon at energies as low as 0.3 keV, where only 1.1 ionized electrons are produced on average?
  • RQ2How does the ionization yield deviate from extrapolations of existing data at sub-1 keV energies?
  • RQ3What is the dependence of ionization yield on the applied drift electric field in liquid xenon, and how does it compare to prior assumptions?
  • RQ4How does the measured ionization yield compare to the predictions of the NEST simulation framework at ultra-low energies?
  • RQ5To what extent does single-electron sensitivity enable improved calibration of low-threshold dark matter and neutrino detectors?

Key findings

  • The ionization yield at 0.3 keV is measured at 3.5–4.5 e−/keV, corresponding to an average of 1.1–1.4 ionized electrons per event, the lowest-energy nuclear recoil signal measured to date.
  • A decreasing trend in ionization yield is observed below 1 keV, deviating significantly from simple extrapolations of higher-energy data.
  • A non-negligible dependence of ionization yield on drift field is observed, contradicting earlier conclusions but consistent with higher-energy data, with a weaker field dependence than implemented in the latest NEST version.
  • The measured ionization yield at 2–6 keV agrees with prior LUX measurements but with significantly improved precision.
  • The results provide critical calibration data for experiments targeting sub-1 keV nuclear recoils, including low-mass WIMP and CEνNS searches.
  • The data will directly inform the next generation of NEST simulations, improving modeling of ionization processes at ultra-low energies.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.