Skip to main content
QUICK REVIEW

[Paper Review] Measurement of the Lateral Distribution Function of UHECR Air Showers with the Pierre Auger Observatory

David Barnhill, P. Bauleo|arXiv (Cornell University)|Jul 26, 2005
Astrophysics and Cosmic PhenomenaPhysics and Astronomy1 references9 citations
TL;DR

This paper presents a precise measurement of the lateral distribution function (LDF) of ultrahigh-energy cosmic ray (UHECR) air showers using data from the Pierre Auger Observatory's surface detectors (SD) and hybrid events with fluorescence detectors (FD). By applying a maximum likelihood fit incorporating Poisson and Gaussian signal models, it demonstrates that an NKG-like LDF provides the best description of the data, with S(1000) at 1000 m from the shower core being minimally sensitive to LDF shape uncertainties, making it a robust energy proxy for UHECRs.

ABSTRACT

The Pierre Auger Observatory is being used to study cosmic rays with energies larger than 10 EeV. An essential quantity that must be deduced from data is the lateral distribution function (LDF). Knowledge of the LDF is important for the reconstruction of the shower core and the shower direction. Here we describe how the LDF is measured using the large sample of events recorded with the surface detector (SD) array and with a small sample observed with the fluorescence detectors (FD). For hybrid events, in which SD and FD measurements of the same shower are available, the core position is much better constrained than for SD-only events, thus providing an important cross-check on the LDF determined from SD measurements alone.

Motivation & Objective

  • To accurately measure the lateral distribution function (LDF) of ultrahigh-energy cosmic ray (UHECR) air showers using data from the Pierre Auger Observatory's surface detector (SD) array.
  • To compare LDFs derived from SD-only events with those from hybrid events (SD + fluorescence detector) to validate reconstruction methods and reduce systematic uncertainties.
  • To determine the optimal distance for measuring the ground parameter S(1000), minimizing sensitivity to LDF shape and shower-to-shower fluctuations.
  • To quantify the dependence of the LDF slope β on zenith angle and energy, and assess the impact of saturated stations and signal fluctuations on core reconstruction.

Proposed method

  • A maximum likelihood fit is used to simultaneously determine the shower core position and LDF parameters by comparing measured tank signals (in VEM) to predicted values from trial LDF functions.
  • For low signals (<15 VEM), the Poisson probability density function f_P(n, μ) is used; for higher signals, the Gaussian approximation f_G(n, μ) is applied.
  • Saturated tanks are handled by integrating the Gaussian function over values exceeding the measured signal, and zero-signal tanks are modeled using cumulative Poisson probabilities with μ ≤ 3.
  • Three LDF functional forms are tested: power law, NKG-like, and Haverah Park-inspired, with the NKG form showing best agreement with data.
  • The Poisson factor P(r, θ, E, A) converts VEM signals to effective particle numbers n, derived from simulations and assumed independent of primary energy and mass.
  • The optimal ground parameter r_opt is determined by identifying the distance where LDFs of varying slope intersect, minimizing sensitivity to LDF uncertainty.

Experimental results

Research questions

  • RQ1Which functional form best describes the lateral distribution of particles in UHECR air showers observed by the Pierre Auger Observatory?
  • RQ2How does the LDF slope β depend on zenith angle and shower energy, and is this consistent between SD-only and hybrid measurements?
  • RQ3To what extent do signal fluctuations and saturated stations bias the reconstruction of the shower core and LDF parameters?
  • RQ4At what radial distance from the shower core is the ground parameter S(r) least sensitive to uncertainties in the LDF shape?
  • RQ5Can hybrid events provide a reliable cross-check on SD-only LDF measurements, and how do their results compare?

Key findings

  • The NKG-like LDF provides the best fit to the data, with a slope β that varies with zenith angle according to β = a + b(secθ − 1), and is well described by a fixed r_s = 700 m.
  • The hybrid analysis shows good agreement with SD-only results, with slope parameters b = −1.1 ± 0.3 (hybrid) and b = −0.98 ± 0.02 (SD), indicating consistency across detection methods.
  • The optimal ground parameter r_opt for minimizing sensitivity to LDF uncertainty is found to be approximately 940 m (mean) with a 110 m RMS deviation across ~500 events with 10^18.5–10^19 eV and θ < 60°.
  • For simulated 10^20 eV events, r_opt has a mean of 930 m and a 40 m RMS, confirming robustness across energy and geometry.
  • S(1000) is minimally affected by LDF shape uncertainty, making it a highly robust proxy for primary cosmic ray energy, especially when the LDF is known to within ±8% in slope.
  • Saturated stations significantly bias r_opt outward by several hundred meters, but this effect is quantifiable and does not invalidate the use of S(1000) as a stable energy indicator.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.