[Paper Review] Measurement of the W-boson helicity fractions in top-quark decays at CDF
This paper presents a measurement of W-boson helicity fractions in top-quark decays using 955 pb⁻¹ of data from the CDF II detector at the Tevatron. By reconstructing top-quark and W-boson four-vectors and analyzing the decay angle θ*, the study finds F₀ = 0.59 ± 0.12 (stat) ⁺⁰.⁰⁷₋₀.⁰⁶ (syst) and F₊ = -0.03 ± 0.06 (stat) ⁺⁰.⁰⁴₋₀.⁰³ (syst), consistent with the Standard Model prediction and setting an upper limit of F₊ ≤ 0.10 at 95% CL.
We present a measurement of the fractions F_0 and F_+ of longitudinally polarized and right-handed W bosons in top-quark decays using data collected with the CDF II detector. The data set used in the analysis corresponds to an integrated luminosity of approximately 955 pb-1. We select top-antitop candidate events with one lepton, at least four jets, and missing transverse energy. Our helicity measurement uses the decay angle theta*, which is defined as the angle between the momentum of the charged lepton in the W boson rest-frame and the W momentum in the top-quark rest-frame. The cos(theta*) distribution in the data is determined by full kinematic reconstruction of the top-antotop candidates. We find F_0 = 0.59 +- 0.12 (stat) +0.07 -0.06 (syst) and F_+ = -0.03 +- 0.06 (stat) +0.04 -0.03 (syst), which is consistent with the standard model prediction. We set an upper limit on the fraction of right-handed W-bosons of F_+ < 0.1 at the 95% confidence level.
Motivation & Objective
- To measure the fractions of longitudinally polarized (F₀) and right-handed (F₊) W bosons in top-quark decays at the Tevatron.
- To test the Standard Model prediction that W bosons from top decay are predominantly left-handed or longitudinally polarized.
- To search for deviations indicating new physics, such as a V+A component in the Wtb vertex or anomalous couplings.
- To correct for detector acceptance and resolution effects using a transfer function to unfold the true θ* distribution.
- To set a 95% confidence level upper limit on the fraction of right-handed W bosons.
Proposed method
- Event selection uses the 'lepton+jets' channel with one isolated lepton, missing transverse energy, at least four jets, and one b-tagged jet.
- Full kinematic reconstruction of t¯t events is performed by constraining W boson mass and top quark mass difference, and using a neural network b-tagger for b-jet identification.
- The decay angle θ* is defined as the angle between the charged lepton momentum in the W rest frame and the W momentum in the top-quark rest frame.
- A binned maximum likelihood fit is used to extract F₀ or F₊, with signal and background contributions modeled using the theoretical θ* distribution (eq. 1).
- Acceptance and migration effects are corrected using a transfer function τ(F₀, F₊), derived from PYTHIA Monte Carlo simulations.
- Unfolding is applied to the observed θ* distribution to compare with theoretical predictions, normalized to the t¯t cross section of 6.7 pb.
Experimental results
Research questions
- RQ1What is the measured fraction of longitudinally polarized W bosons (F₀) in top-quark decays?
- RQ2What is the measured fraction of right-handed W bosons (F₊) in top-quark decays, and is it consistent with zero?
- RQ3Does the observed W-boson helicity distribution deviate from the Standard Model prediction of F₀ = 0.7 and F₊ = 0?
- RQ4What is the 95% confidence level upper limit on the fraction of right-handed W bosons?
- RQ5How do detector acceptance and reconstruction effects impact the measured θ* distribution, and how are they corrected?
Key findings
- The measured fraction of longitudinally polarized W bosons is F₀ = 0.59 ± 0.12 (stat) ⁺⁰.⁰⁷₋₀.⁰⁶ (syst), consistent with the Standard Model prediction of F₀ = 0.7.
- The measured fraction of right-handed W bosons is F₊ = -0.03 ± 0.06 (stat) ⁺⁰.⁰⁴₋₀.⁰³ (syst), consistent with zero and the Standard Model prediction.
- An upper limit of F₊ ≤ 0.10 is set at the 95% confidence level, consistent with the absence of right-handed W bosons.
- The unfolded θ* distribution, corrected for detector effects, shows good agreement with the Standard Model prediction.
- The transfer function method successfully accounts for acceptance and resolution effects, enabling a direct comparison between data and theory.
- The results are robust under systematic uncertainties and support the validity of the Standard Model for top-quark decay helicity.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.